Commissioning and operation
79
Description of acoustic signal transmitter
Warnings and alarms can be reproduced via the acoustic signal transmitter..
Interval signal
tone
Event
Meaning
fast
actuation of the button
Handover of the control console possible
slow
Initialisation of the connected control
Handover of the control console is requested
actuation of the button
Handover of the control console not possible
Continuous tone
Fault alarm of the connected control
Alarm
Activate control console
If the control is switched on via the master switch, first all control consoles are initialised.
This is indicated by a slow flashing LED on each control console.
D
D
and an unbroken acoustic signal.
During the initialisation
D
the control consoles are inactive and
D
the vessel cannot be controlled from any control console.
Select control head
Select the control head by actuating
the button.
TheLEDs and signal tone stop on all other control consoles.
If the levers are not in the “Neutral“ position, the LEDs continue to flash
and the sig
nal tone remains the same.
If necessary, place the lever in the “Neutral" position.
The LEDs
now flash quickly and the signal tone is faster.
Extinguish the LEDs by
pressing the button again
.
The control console is active and the engine can be started.