- 23 -

11. Environmental protection and disposal

Please dispose of 

mamivac

®

 SENSITIVE-CFH

 breast pumps out of order in accordance with your local dis-

posal regulations for electrical devices.

12. Technical data

mamivac

®

 SENSITIVE-CFH: 

REF 286000 

Device classification

Nominal voltage: 

100-240 V/AC 50 - 60 Hz  

Classified acc. to 93/42/EEC

 

max. 0.62 A  

Article 9, Appendix IX: Class IIa/Rule 11 

H x W x D: 

24 cm x 21 cm x 22 cm

Weight: 

1.3 kg 

Max. vacuum: 

-5 to -33 kPa (±15%)

Mean vacuum: 

Device for intermittent sucking without continuous vacuum

Power cord: 

2 cores 2 x 0.75 mm; H05VVH2-F 3.0 m long with Euro plug (REF 283003)

Protection class: 

II

13. Conversion table of units

1 kPa

 

corresponds: 

0.01 bar

0.14504 PSI

 

corresponds: 

7.5006 mmHg

(pounds per square inch) 

 

(millimetre mercury, at 0 °C)

 

14. Legend

Observe safety instructions

Manufacturer

Observe operating instructions

Protect from sunlight

Store in dry place

Protection against penetration of solid par-

ticles of a diameter ≥1.0 mm. No protection 

against penetration of water.

Conformity mark according to

EU Council Directive 93/42/EEC

Direct current

Device of protection class II

Alternating current

Patient applied part of type BF

Do not dispose in domestic waste

On

Serial number

Off

Item number

Observe operating instructions

SN

REF

IP40

Summary of Contents for SENSITIVE-CFH

Page 1: ...ng instructions electric breast pump only for clinical use REF 286000 As of 2018 12 GB1010029GB Tel 49 0 71 56 1 76 02 100 Fax 49 0 71 56 1 76 02 500 info kaweco de KaWeCo GmbH Gerlinger Str 36 38 712...

Page 2: ...reast pump 19 4 1 The mamivac 2 phase technology 19 4 2 The stimulation phase 19 4 3 The expressing phase 20 4 4 Switching off the device 20 5 Hygiene and cleaning 20 5 1 Cleaning and servicing the br...

Page 3: ...jaw palate diseases of the mother where breastfeeding the baby is contraindicated over a limited period of time e g taking medicine 1 2 Contraindications A possible contraindication is being allergic...

Page 4: ...inuously adjustable cycle control c Status LED flashing green ready for use yellow self testing red error message d Bottle holder e LED for mains operation green ready for use f Connection for suction...

Page 5: ...portation of the device with the mobile stand make sure that the extension is completely retracted 3 2 Components of the mobile stand o Mobile stand REF 283012 p Cylinder head bolt REF 49020841 q Wash...

Page 6: ...The mamivac 2 phase technology The mamivac SENSITIVE CFH breast pump simulates the baby s natural sucking behaviour It can be divided into two phases stimulation phase and expressing phase 4 2 The sti...

Page 7: ...perating instructions of the suction kit Do not use chemical disinfection baths solvents or abrasives All parts of the mamivac suction kits except for the air tube and the tube connection can be clean...

Page 8: ...ces or shortwave therapy devices For a detailed technical description of the electromagnetic environment visit https www mamivac com en knowledge download Provided that the mamivac SENSITIVE CFH breas...

Page 9: ...suction kit Expressing scheme Express first and second breast 5 minutes each one after the other followed by 3 minutes and 2 minutes each With two suction kits Express both breasts simultaneously for...

Page 10: ...cores 2 x 0 75 mm H05VVH2 F 3 0 m long with Euro plug REF 283003 Protection class II 13 Conversion table of units 1 kPa corresponds 0 01 bar 0 14504 PSI corresponds 7 5006 mmHg pounds per square inch...

Page 11: ...unit 2899120 Clinic stand 283012 mamivac suction kit ECONOMY L 283122 mamivac double kit ECONOMY L 283124 mamivac suction kit PREMIUM L 283120 mamivac double kit PREMIUM L 283123 Breast tube XL for s...

Reviews: