MALUX FernTel IP Z2 Instructions Manual Download Page 6

6

Technical Specifications

Connection data at X101

Power supply 

Power over Ethernet according to IEEE 802.3af

Voltage POE 

48 VDC (min. 44 V, max. 61 V)

Power consumption 

3.5 W

Display 

128 x 64 pixels

Ringing sound pressure level 

max. approx. 95 dB (A) at 1 m

Housing (height x width x depth) 

293 x 191 x 128

Weight 

approx. 2,300 g

Operating position 

Table or vertical wall mounting

Receiver

Microphone 

Electret-foil microphone

Receiver inset 

Dynamic receiver inset with magnetic field generator

Connection X101 

(10/100 Mbit/s) LAN cable with 8 conductors 
AWG 22 to 24 for solid conductors, or 
AWG 24 for multi-wired conductors

Dimensions Connecting cable / Cable entry

Cable glands 

M20 x 1,5 

Blind plugs 

M20 x 1,5 / M12 x 1,5

Connecting cable diameter 

6 – 13 mm

Connection potential compensation 

1,5 – 4 mm

2

Ambient temperature range and explosion protection

Type of protection 

Ex nA ic IIC T5 Gc
Ex tc ic IIIC T80°C Dc

Operating ambient temperature range  -20°C 

 Ta 

 +55°C

Storage and transport temperature 

-25°C 

 Ta 

 +70°C

Housing degree of protection 

IP65

Labelling

Firma 

FHF Funke+Huster Fernsig GmbH

Type 

FernTel IP Z2

DEKRA

BVS 08 ATEX E 022

CE 0158

II 3 G Ex nA ic IIC T5 Gc
II 3 D Ex tc ic IIIC T80°C Dc
-20°C 

 Ta 

 +55°C 

IP65  U

m

= 61 VDC; U

n

= 48 VDC

IECEx

Ex nA ic IIC T5 Gc
Ex tc ic IIIC T80°C Dc
IECEx BVS 08.0009

www.malux.se

Reviews: