follows:
c)
When the unit operates in the cooling operation, drying operation, the ambient temperature
sensor senses the evaporator coil temperature is below -1°C, after the compressor will stop
operating for 10 minutes or the coil temperature up to 7 , the unit restart to cool operating
℃
mode.
d)
When the unit operates in the drying operation, once the coil temperature sensor senses the
temperature of the evaporator is below 40
℃
and the differential temperature between coil
temperature and room temperature is below 19
℃
after the compressor operation for
20minutes, the unit start defrosting for 5 minutes and the power indicator blinking.
5.3.5 Overload Protection
In the event of a power loss, to protect the compressor there is a 3-minute delay until the compressor
restarting.
5.4 DRAINAGE
Manual drainage:
1
)
When the machine stops after the water is full, please unplug the power plug.
Notes: Please move the machine carefully, so as not to spill the water in the water pan at the bottom
of the body.
2
)
Place the water container below the side water outlet behind the body.
3
)
Unplug the water plug, the water will automatically flow into the water container.
Notes:
1. Keep the water plug properly.
2. During drainage, the body can be tilted slightly backwards.
3. If the water container cannot hold all the water, before the water container is full, stuff the water
outlet with the water plug as soon as possible to prevent water from flowing to the floor or the carpet.
4
)
When the water is discharged, stuff the water plug.
Notes: 1. Restart the machine after the water plug and drainage cover are installed, otherwise
condensate water of the machine will flow to the floor or the carpet.
Continuous drainage
35
Summary of Contents for KLP-9000KWA
Page 1: ...Klimatyzator Przeno ny KLP 9000KWA Instrukcja obs ugi i konserwacji 1 59...
Page 13: ...13 59...
Page 20: ...Importer MALIS B Macho ski sp k ul Zbo owa 2E 62 081 Wysogotowo www maltec pl 20...
Page 21: ...PORTABLE AIR COOLER KLP 9000KWA Instruction Manual 21...
Page 28: ...2 Hose connector 3 Window kit adapter 4 Remote control 5 Window kit 28...
Page 33: ...33...
Page 41: ...Wartungsanleitung 41...