INSTRUCTIONS FOR SAFE USE OF
WNL+ LAPTOP TROLLEY
2 z 3
Manufacturer: MALOW Sp. z o. o., st. Wojska Polskiego 114A, 16-
400 Suwałki
13. Laptops should be placed inside the product. Maximum working space size - 96 x 340 x 470 mm.
Connect the laptop power supplies to the electrical sockets located in the profiles (item 4).
14. Switch the main switch (from 0 to 1) (pos. 1) in the trolley. The power signal will be the switch's
backlight (green).
15. When the charging cycle is complete, switch the trolley off with the switch to position 0.
16. The maximum load current of all connected devices must not exceed 16A. If the permissible current
is exceeded, a fuse will trip (pos. 1). Check for damage to the trolley and connected devices and
reset the fuse by pressing the fuse button until it snaps into place.
17. The trolley can be equipped with a switch (item 3*) (WNL+S model) or a router (item 5*) (WNL+R
model). In the version with switch, the user can start working in the network directly after connecting
the power supply and LAN cables to laptops. The version with a router may require initial
configuration. In the case of physical access to the device it is necessary to unscrew the tabletop
according to fig. 3. This should be done by qualified personnel with disconnected power supply to
the trolley.
18. With upper equipment there will be additional necessary sockets on side of the trolley. In case of
router it
’s USB and 2x RJ45 for LAN and WAN. I case of switch 1x RJ45 for LAN. (pos 7*)
19. The included mounting set for the handle does not include tools. Picture 2 shows how to mount the
handle.
20. Do not expose the trolley to weather conditions (rain, sun, etc.). The trolley is intended for use in dry
and ventilated rooms.
21. The maximum load of the shelf is 10 kg.
22. When charging, check the battery charge level and temperature inside the trolley.
23. Dispose of the waste device.
Technical data of the production equipment:
1. Profile(s) (item 4) equipped with 16 A 230 V sockets.
2. Sequence charging module (item 1) equipped In:
•
illuminated switch
•
16 A 230 V automatic fuse,
•
main connection cable with plug (pos. 2).
•
Optionally IEC C20* socket (in case of detachable cable)
•
Optionally surge protection cl. D and/or socket* for switch/router.
3. Option: Switch (pos. 3*) 16 LAN ports RJ45, 1 for column - details in the device manual.
4. Option: Router TP-Link Archer C1200 V2 (item 6*) - details in the device manual.
5. Mounting set for the handle (fig. 2)
Items with "*" are only available in the trolley with the selected optional equipment.
Drawing 2 Mounting hnadle
Drawing 3 Unscrewing tabletop