INSTRUCTION MANUAL
WARDROBE FOR DRYING CLOTHES
2 of 2
Manufacturer: MALOW Sp. z o. o., St. Wojska Polskiego 114A, 16-400 Suwałki
this situation it is necessary to turn of the trolley and reset them by pressing button on overheat
breaker located on bottom until feel it “click”.
9. The activation of the breaker may be caused by overcurrent made by socket or damage of the
wardrobe (look point 4 – 5).
10. For start the drying do:
a) Turn on FAN with the switch (Draw. 1 pos. 6), the switching position is signaled by backlight.
b) Heater turn on with the switch (Draw. 1 pos. 8), the switching position is signaled by backlight.
c) Heater will not work if fan is disabled.
d) Turning of the fan switch cause automatic turning of the heater.
11. After 4-9** hours from turn on of the fan, the wardrobe will turn off. To start process again turn of the
fan switch (Draw. 1 pos. 6) and made steps from point 10 or after temporary voltage loss.
12. Before lock the doors check if inside there are no animals and unnecessary items.
13. Maintenance or service of the locker make with disconnected power supply. Do not use strongly
caustic detergents for clearing the locker. Clean locker with dry or damp cloth. Systematically
change filter and clean metal net by filter and in air corridor. (draw. 2).
14. Do not put inside very wet clothes (dripping with water).
15. Do not cover ventilation channels located on top of wardrobe (Draw. 1 pos. 1) and under them
(Draw. 1 pos. 2). If it is possible connect ventilation holes to building ventilation (2 pipes Ø 100 mm).
16. This appliance is intended for use up to a maximum height of 2000 meters above sea level.
17. Do not expose the trolley to weather conditions (like rain, sun, etc.). The locker is designed to
function in dry and ventilated room.
18. Max. Load per shelf is 30 kg.
19. Worn out locker should be safely dismantled and disposed of.
Technical data:
1. Fan 230 V, 50 Hz, 33 W, 150 m³ / h.
2. *Socket with ground, 16 A, ~230 V (Draw. 1 pos. 3).
3. LED indicator of power the socket and ready to dry 230 V, 50 Hz (Draw. 1 pos. 9)
4. Heater – Max 2 x 1000 W 230 V, 50 Hz.
5. Automatic thermal fuse 230 V, 16 A (Draw. 1 pos. 7).
6. Connection cable plug with ground 230 V, 16 A (Draw. 1 pos. 5).
7. **Time relay with time set by factory depending on model 230 V, 50 Hz, 16 A.
8. Nominal power of wardrobe 550 - 2000 W, max 3680 W - in version with socket, limited by fuse.
9. Replaceable filter G3 100 g/m2 140 mm x 350 mm (Draw. 2 pos. 11)
Drawing 2 Way of disassembly of air corridor and filter from ventilation module