background image

TJ-JA-121009

Lamp Post Idefjord 100

Model: 9001/9002/9003

77 600 16-28

InSTrucTIOn ManuaL

Malmbergs Elektriska aB, PO Box 144, SE-692 23 kumla, SWEdEn   

Phone: +46 (0)19 58 77 00     Fax: +46 (0)19 57 11 77     [email protected]     www.malmbergs.com

EN

art.no.

colour

no. of lamps Height (m)

77 600 16

Black

1

1.8

77 600 17

White

1

1.8

77 600 25

Black

2

2.5

77 600 26

White

2

2.5

77 600 27

Black

3

2.5

77 600 28

White

3

2.5

TEcHnIcaL daTa

Lamp:

 

Energy saving lamp max. 18W, E27.

Connection:

 

Terminal block 3x2.5 mm².

Protection class:

 IP44.

Note: Please read the instructions carefully before installation and keep the instruction manual 
for future reference.

InSTaLLaTIOn dIrEcTIOnS

Please ensure that the power is off prior to installa-
tion, and pay attention to the following steps; 
care should be taken to align bolts and threads to 
ensure no cross threading.

Preparing the Foundation

1.  Make sure the power is cut off before installa-

tion.

2.  check all the parts of the lamp post.
3.  dig a hole in the ground with the dimensions 

LxWxd: 10×10x16 inches.

4.  Put the bolts in the mounting triangle and fix into 

the hole. Make sure that the bolts are sticking up 
enough through the base so that the pole can be 
fixed with the domed nuts supplied. Fill the hole 
with concrete. More than 20 inches of the cable 
must stick up from the ground.

5.  Mount the lamp post after the foundation has 

hardened.

Mounting the Lamp Post  
(see FIG. 1 and 2, last page)

1.  connect the cable to the terminal block. Pull 

the cable to the terminal block through the post 
from the bottom to the top. Fix the base on the 
foundation with M8 nuts.

2.  connect the cable from the lantern(s) to the top 

terminal block.

3.  Mount the lantern(s) on the post. Fix with 

screws.

Note:

 users should keep cleaning the glass often. do 

not use the light without protection glass and change 
the glass immediately if it is broken.

SaFETy dIrEcTIOnS

• 

Electrical work may only be carried out with the 
mains voltage switched off and only by a qualified 
electrician.

• 

after turning on the switch, the bulb will become 
hot. When the bulb is lit or not completely cooled, 
please do not touch the bulb with bare hands.

• 

When changing the bulb, please cut off power 
first and change the bulb after it has cooled down 
(see changing the Bulb below for details).

cHangIng THE BuLB

1.  Turn off the power.
2.  remove the top of the lantern.
3.  Screw the cooled bulb off carefully.
4.  The new and clean bulb should be screwed into 

the lamp holder correctly.

5.  Before turning on the power, replace the top of 

the lantern.