5.  OpERATING INSTRUCTIONS

5.1 AC and DC Voltage Measurement

  1)  Set the rotary switch to the voltage position (V  / V-).
  2)  Insert the black test lead into the negative 

COM

 jack; insert the red test lead into the 

positive 

V/

Ω

mA

 jack.

  3)  The polarity of red test lead connection will be indicated when making DC Voltage 

measurement. 

5.2 Current Measurement 

  1)  Remove the power from the circuit under test and discharge any capacitors of the 

circuit, set the rotary switch to suitable current measuring range.

  2)  Insert black test lead into the negative 

COM

 jack, for current measurement less than 

200mA insert the red test lead into the mA jack, for current measurement between 
200mA to 10A insert the red test lead into 10A jack.

5.3 Diode Test and Buzzer Check

Disconnect power to the unit under test and discharge all capacitors before taking diode test.

  1)  Set the rotary switch to 

 

 position.

  2)  Insert the black test lead into the negative 

COM

 jack, insert the red test lead into the 

positive 

Ω

mA

 jack.

Diode test:

• 

 place the red test lead on the anode of diode and black test lead on the cathode of 
diode, the meter will show the approx. forward voltage of diode, reverse voltage will 
indicate 

OL

.

Buzzer test:

• 

 Touch the test probe tips to the circuit or wire you wish to check, the max. value of re-
sistance under check will be showed in display, if the resistance is less than 70

Ω

±30

Ω

the audible signal will sound.

5.4 Resistance Measurement 

Disconnect power to the unit under test and discharge all capacitors before taking any 
resistance measurements. Remove the batteries and unplug the line cords. 
  1)  Set the rotary switch to the desired resistance range.
  2)  Insert the black test lead into the negative 

COM

 jack, insert the red test lead into the 

positive

 V 

Ω

mA

 jack.

  3)  Touch the test probe tips across the circuit or part under test. It is best to disconnect 

one side of the part under test so the rest of the circuit will not interfere with the 
resistance reading. 

NOTE: In an open circuit, the meter will display OL.

Summary of Contents for HK36A

Page 1: ...Modell Malli Model HK36A 42 016 18 BRUKSANVISNING EN FI SE Digital multimeter INSTRUCTION MANUAL Digital Multimeter K YTT OHJEET Digitaalinen yleismittari...

Page 2: ...Hold funktion Automatisk avst ngning Tillbeh r manual m tsladdar Denna multimeter m ter V xel liksp nning V xel likstr m Resistans Diodtest Kontinuitetstest Temperatur Batterier Ber ringsfri sp nnings...

Page 3: ...r att undvika skador p instrumentet verstig ej de v rden som visas i specifikatio nerna Om m tinstrumentet inte ska anv ndas under en l ngre tid ta ut batterierna och f r vara dem separat 4 1 Noggrann...

Page 4: ...esistans Omr de Uppl sning Noggrannhet 200 0 1 1 0 avl sning 2 siffror 2k 0 001k 20k 0 01k 200k 0 1k 2M 0 001Mk 1 0 avl sning 2 siffror 20M 0 01M verbelastningsskydd 250V DC eller 250V AC RMS Maximal...

Page 5: ...tsladden i det negativa COM uttaget s tt i den r da m tsladden till den positiva V mA uttaget Diodtest Placera den r da m tsladden p diodens anod och den svarta m tsladden p diodens katod Instrumentet...

Page 6: ...av sp nning Resultatet kan p verkas av eluttagets utformning isoleringens tjocklek och andra fak torer Yttre st rningsk llor s som ficklampa motorer etc kan ocks p verka resultatet 5 7 Sp nningprovni...

Page 7: ...n observera r tt polaritet 4 S tt tillbaka batteriluckan f st med skruvarna 6 2 Byte av s kringar 1 Sl av str mmen och koppla bort m tsladdarna fr n instrumentet 2 Ta bort batteriluckan och batteriet...

Page 8: ...uojaus joka toiminnossa Mittaustuloksen muisti Auto OFF Tarvikkeet k ytt ohje mittausp t Mittaustavat AC DC j nnite AC DC virta Resistanssi Dioditesti Jatkuvuustesti L mp tila Paristoj nnite Kontaktit...

Page 9: ...ttarissa l ylit ohjeessa ilmoitettuja m reiden maksimiarvoja Jos mittaria ei k ytet pidemp n aikaan irrota paristot ja s ilyt ne erill n mittarista 4 2 1 DC j nnite Alue Erottelukyky Tarkkuus 200mV 10...

Page 10: ...Alue Erottelukyky Tarkkuus 200 0 1 1 0 lukema g 2 merkki 2k 0 001k 20k 0 01k 200k 0 1k 2M 0 001Mk 1 0 lukema 2 merkki 20M 0 01M Ylikuormitussuoja 250V DC tai 250V AC RMS Maksimij nnite mitattavassa p...

Page 11: ...itse kiertokytkimest asento 2 Aseta musta mittajohto COM liittimeen ja punainen mittajohto V mA liittimeen Dioditesti Aseta punainen mittajohto diodin anodiin ja musta mittajohto diodin katodiin mitta...

Page 12: ...in perusteella Pistorasian muotoilu eristepaksuus ja muut tekij t voivat vaikuttaa mittaustulokseen Ulkoiset h iri l hteet kuten k sivalaisimet moottorit ym voivat aiheuttaa v r n mittaustuloksen 5 7...

Page 13: ...sta 4 Aseta paristokotelon kansi paikoilleen ja kiinnit ruuvit 6 2 Sulakkeiden vaihtaminen 1 Sammuta mittari ja irrota mittajohdot 2 Irrota paristokotelon kansi ja paristo 3 Avaa takakannen ruuvit ja...

Page 14: ...nction Auto power off Accessories user manual test leads This range meter measures AC DC Voltage AC DC Current Resistance Diode Test Continuity check Temperature Battery Non Contact Voltage Detection...

Page 15: ...to the meter do not exceed the maximum limits of the input values shown in the specifications If the meter is not to be used for a longer period of time remove the batteries and store them separately...

Page 16: ...ution Accuracy 200 0 1 1 0 reading 2 digits 2k 0 001k 20k 0 01k 200k 0 1k 2M 0 001Mk 1 0 reading 2 digits 20M 0 01M Overload protection 250V DC or 250V AC RMS Maximum open circuit voltage 3 2V 4 2 5 D...

Page 17: ...test lead into the negative COM jack insert the red test lead into the positive V mA jack Diode test Place the red test lead on the anode of diode and black test lead on the cathode of diode the mete...

Page 18: ...r reference do not determine the voltage by NCV detection ONLY Detection may interfere by socket design insulation thickness and other variable con ditions External interference sources such as flashl...

Page 19: ...rrect polarity 4 Put the battery cover back in place secure with the screws 6 2 Replacing the Fuses 1 Turn power off and disconnect the test leads from the meter 2 Remove the battery cover and the bat...

Page 20: ...Malmbergs Elektriska AB PO Box 144 SE 692 23 Kumla SWEDEN Phone 46 19 58 77 00 Fax 46 19 57 11 77 info malmbergs com www malmbergs com MJ JA JZ 160323...

Reviews: