![Malmbergs AP110012 Instruction Manual Download Page 7](http://html.mh-extra.com/html/malmbergs/ap110012/ap110012_instruction-manual_698305007.webp)
7
OPERATING GUIdE
The device is ready for use out of the box. Inspect the machine for damage and airflow
obstructions prior to plugging it in or operating it. Ensure the power switch is in the Off
position. Place the unit on the ground. Ensure that the machine rests stable and secure
and will not overturn. Plug the unit into a grounded outlet and switch on.
•
do not run over cord and do not handle power cord plug with wet hands.
•
Keep cord away from heated surfaces.
•
Turn off the fan before unplugging.
•
do not use when you are tired, distracted or under the influence of drugs, alcohol or
medication.
MAINTENANCE
WARNING! Disconnect the unit from power before servicing or cleaning. Replace the
safety grill after servicing, lubrication or cleaning.
Servicing
Before each use, inspect for damage, blocked inlet or outlet, or any excess buildup of
foreign material. When the device is first turned on, check for excessive vibration. If the
unit vibrates excessively or if blower wheel rubs on housing, turn off the unit immediately.
Have a service technician inspect the unit to locate the problem.
Cleaning
The housing is made of a durable and washable polyethylene. When cleaning, the use of
solvents is NOT recommended. for questions, accessories and spare parts, please visit our
website www.malmbergs.com
SPECIfICATIONS
Power supply
750W
Voltage
230V~, 50Hz
Max. current
4.9A
Speed
2850 RPM
dims (WxHxd) 38x53x49 cm
Weight
13 kg
IP rating
IP22