background image

3

MALLORY IGNITION

www.malloryracing.com

IGNITION SWITCH

OIL PRESSURE SWITCH

TO ACCESSORIES

TO COIL (+)

GROUND

GROUND

COMMON

FUSE (25 AMP)

NORMALLY

OPEN

NORMALLY

CLOSED

FROM

VEHICLE

BATTERY

STARTER

VEHICLE

BATTERY

FUEL

PUMP

RED

BLACK

12 VOLT OUTPUT
TERMINAL ON
STARTER THAT
HAS 12 VOLT ONLY

Y

WHILE STARTER
IS CRANKING

FIGURE 4

FIGURE 3

IGNITION SWITCH

TO ACCESSORIES

TO COIL (+)

GROUND

FUSE (25 AMP)

FROM

VEHICLE

BATTERY

FUEL

PUMP

RED

BLACK

WIRING PROCEDURE

Wiring a pump to an oil pressure switch will provide
power only when the ignition switch is on and the engine
is running. This will prevent the pump from running if
your engine stalls. Use 12 gauge wire or larger and be
sure to disconnect the battery ground cable before wiring
the pump. Refer to Figure 3 when connecting the pump
to an oil pressure switch.

The pump may also be wired directly to the ignition “ON” terminal and grounded
to the frame or battery. Refer to Figure 4 when connecting the pump to the 
ignition switch “ON” terminal.