3
MALLORY IGNITION
www.malloryracing.com
IGNITION SWITCH
OIL PRESSURE SWITCH
TO ACCESSORIES
TO COIL (+)
GROUND
GROUND
COMMON
FUSE (25 AMP)
NORMALLY
OPEN
NORMALLY
CLOSED
FROM
VEHICLE
BATTERY
STARTER
VEHICLE
BATTERY
FUEL
PUMP
RED
BLACK
12 VOLT OUTPUT
TERMINAL ON
STARTER THAT
HAS 12 VOLT ONLY
Y
WHILE STARTER
IS CRANKING
FIGURE 4
FIGURE 3
IGNITION SWITCH
TO ACCESSORIES
TO COIL (+)
GROUND
FUSE (25 AMP)
FROM
VEHICLE
BATTERY
FUEL
PUMP
RED
BLACK
WIRING PROCEDURE
Wiring a pump to an oil pressure switch will provide
power only when the ignition switch is on and the engine
is running. This will prevent the pump from running if
your engine stalls. Use 12 gauge wire or larger and be
sure to disconnect the battery ground cable before wiring
the pump. Refer to Figure 3 when connecting the pump
to an oil pressure switch.
The pump may also be wired directly to the ignition “ON” terminal and grounded
to the frame or battery. Refer to Figure 4 when connecting the pump to the
ignition switch “ON” terminal.