15
If a cooking zone remains lit for too long at the same power level, the appliance will
automatically switch it off, and the residual heat indicator H will appear. Switch it back on to reset
the cooking zone’s operation.
The table below lists the maximum uninterrupted operating time for each power level:
Powen
Operating limit in minutes
1
520
2
402
3
318
4
260
5
212
6
170
7
139
8
113
9
90
P
5
The timer function can be set from 1 to 99 minutes on each cooking zone.
To activate the timer: select a cooking zone and set the desired power level, then simultaneously
press the + and - keys, and press + or – to set the desired minutes. A buzzer will sound of 2 minutes
duration will indicate the end of the time setting, and the cooking zone will switch off automatically.
The countdown function can be set from 1 to 99 minutes, but contrary to the timer it does not
switch off the cooking zone.
The end of the minutes set will be given by an acoustic signal.
With the hob on: without selecting a cooking zone, simultaneously press keys + and -, then use +
or – to set the desired minutes.
Once set, it continues to work also having switched off the hob until the minutes set end.
The cooktop is equipped with a safety-lock to ensure that it is not inadvertently switched on by
children. It can be activated only if the cooking zones have not been selected. To enable the Child
Timer
Countdown
Child-Lock safety function
IGB
OPERATION
Summary of Contents for MI-784 ITG
Page 1: ...USER MANUAL H NG D N S D NG MODEL MI 784 ITG...
Page 2: ......
Page 10: ......
Page 11: ...MI 784 ITG...
Page 12: ......
Page 13: ...X Drawer Y Built in cooker built in oven...
Page 27: ......
Page 28: ...MI 784 ITG...
Page 29: ......
Page 30: ...H nh H nh X Ng n K o Y L m t...