malema.com
Cut Dimensional Drawings
Illustrated is the M-200X model with 1/2” ports.
Flow Setting Information
Ordering Information
Standard Part Numbering
M
-
Model
-
Material
Port
Switch
-
XXX
M
-
200X
-
S
3
3
XXX
200X
B - Brass
S - 316SS
T - PTFE
3- 3/8”
4- 1/2”
6- 3/4”
XXX
Note:
The flow switch performance will be affected in the vicinity of Magnets, Electromagnets, and Ferrous metals. Hence
adequate protection should be provided while installing in close proximity to such interferences or relocate the flow
switch away from them appropriately.
07
This model is a
adjustable
flow switch. The flow set point is fixed at the factory and is field adjustable. Proper calibration of the
set point requires the following information. When purchasing a flow switch, use the “Set Point Calibration” form on page i-vi
or provide this information on the purchase order.
•
Calibration set point,
•
Increasing or decreasing flow,
•
Fluid type (i.e. liquid or gas),
•
Density or specific gravity,
•
Viscosity,
•
System pressure and temperature,
•
Flow direction (i.e. upward or downward), and
•
Mounting orientation (i.e. horizontal or vertical).