Manual Ground Balance
Allows you to manually modify the ground balance value. It is not preferred mostly because it
takes time. However, it is the preferred option in cases where a successful ground balance
cannot be performed using other methods or minor corrections are required to the automatic
balance.
GOLD RACER
is designed to allow for automatic ground balancing conveniently on any type of
ground. Therefore, it is recommended to perform automatic ground balance upon start up.
However, the ground may not be suitable for automatic ground balancing in some cases and the
device cannot ground balance on such grounds. For instance, wet beach sand, soils containing
alkali or salty water, lands with high waste metal content, ploughed fields, high mineralized
grounds and grounds with very low mineralization are not suitable for automatic ground
balance. We recommend manual ground balancing for making it easier to search in such areas.
Manual ground balance requires a skill which develops over time through practice.
For performing manual ground balance:
1. Find a spot without metals and switch the device to the All Metal mode.
2. You need to listen the sounds coming from the ground in order to perform manual ground
balance. Pump the search coil up and down from about 15-20 cm (~6''- 8'') above the ground
down to 3 cm (~1'') off the ground with smooth movements and keeping it parallel to the
ground.
If the sound gets higher when lifting off the search coil above the ground, the ground balance
value is too low, in other words, the effect from the ground is negative and the ground balance
value needs to be increased by using the ( + ) button. On the other hand, if the sound gets higher
when lowering the search coil to the ground, the ground balance value is too high, in other
words, the effect from the ground is positive and the ground balance value needs to decreased
by using the ( - ) button.
3. Push the ground balance trigger forward once and release it. The ground balance value will
be shown on the display and remain there for a moment. You can return to the ground balance
screen by pushing the ground balance trigger forward if the screen switches.
Press ( + ) and ( - ) to increase and decrease the ground balance value, respectively. If the key is
pressed once at a time, the values count one by one and if kept pressed down, they change
quickly.
4. Repeat the above procedure until the sound heard from the ground is eliminated.
Manual ground balance functions within the range of 0-99.
However, each value covers 5 steps used for fine tuning
within itself and these steps are indicated as multiples of 20
in the Ground Phase indicator shown on the display. For
example, ground balance value shown on the side is 70.80.
Page_13
Ground Balance