RETURNING TO THE DEFAULT SETTINGS
In order to return to the default settings enter the controller settings mode. Select the
PdOd
option with
buttons ▲,▼. Confirm the selection by pressing button
S
Change the value from „0” to „1” using
button ▲. Then confirm the selection by pressing button
S
. again. Subsequently disconnect the power
from the controller and connect it again.
ATTENTION!
1.
Returning to default settings will result in deleting all the settings from the controller’s
memory and simultaneously bringing back the default settings. Therefore this option
should be applied with proper care and awareness.
2.
Returning to default settings is only effected once the controller’s power supply is
disconnected and connected again.
CONTROLLER OPERATING IN THE TEST MODE
The test mode function is designed for testing the correct operation of the washing system controlled by
UMS-02 controller.
Operating in test mode enables to manually speed up the particular steps of the program.
In order to set the test mode enter the settings mode and set the
UEL
function to 1.
Then confirm it by pressing
S.
To exit the setting mode press the red button
.
The test mode operation is signaled by the flashing green light marked
A
.
Having switched on the program you can pass on to the following steps by pressing ▲. You can also go
back to the previous steps by pressing ▼.
Exiting the test mode:
- enter the access code;
- select the UEL function;
- set the value to 0
- confirm by pressing S;
- exit the settings by pressing the red button
ATTENTION
Having finished the tests of the washing system it is absolutely essential to remember to return to the
regular operation. During the regular operation the green light must not be on.
PRE-SET PROGRAMS
The controller contains 4 pre-set programs presented below. The remaining 4 programs are empty..
Program No 1
LED diode No
1
2
3
4
5
6
7
REMARKS
STEP
TIME
CW ZW PP PML ZZ PMY
H
1
15:00
0
1
0
0
0
1
1
Max. time
2
03:00
0
0
1
0
0
1
0