1. DESCRIPTION. 

 

Temperature  regulator  SMT-05  v.  3  is  a  microprocessor-based,  programmable  temperature 
controller, intended for use in comprehensive servicing of milk coolers, beer wort tanks, all types  
of dryers, chambers and sterilizing and pasteurizing devices, devices for producing juices, heating  
of swimming pools, or for foil tunnels.  
The regulator casing is hermetic (IP 65 protection class) and therefore resistant to humidity, dirt and 
low temperature; electronics of the regulator is able to work in temperatures up to -10 

O

C. The casing 

is adapted for wall mounting. 
In  the  set  with  the  regulator  there  is  a  temperature  sensor  in  the  rubber  cover  (protection  class 
IP68), ended with a stainless steel sleeve. The regulator signals the failure of the temperature sensor. 
A number of functions that the regulator is equipped with, as well as the ability for the user to create 
his  own  regulator  work  program,  make  it  a  universal  controller  to  manage  the  operation  of  the 
refrigeration unit and the stirrer, or e.g. the heater and fan.

 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SMT-05

Page 1: ...sing is hermetic IP 65 protection class and therefore resistant to humidity dirt and low temperature electronics of the regulator is able to work in temperatures up to 10 OC The casing is adapted for...

Page 2: ...ator programmable parameter from 1 min to 60 min standstill time of the stirrer ventilator programmable parameter from 1 min to 60 min temporary operation time of the stirrer ventilator programmable p...

Page 3: ...egulator is connected to the mains it means the cooling heating operation of the regulator is switched off However you can switch on the stirrer s manual operation by pressing the button 3 If the regu...

Page 4: ...stirrer ventilator 3 digital temperature meter allowing for current temperature control independently from switching on or off the regulator 6 LEDs signaling the current operating status of the coolin...

Page 5: ...outin the following way unscrew the screws of the casing cover take off the cover screw the regulator casing to the prepared structure through the fixing holes put on the cover fasten the screws of th...

Page 6: ...ion of the chiller unit when the chiller is switched off the stirrer goes into cyclic operation stirrer ventilator operates only when the chiller heating system is switched on continuous stirrer venti...

Page 7: ...d HE This function is connected with the possibility of delaying the time of switching on the alarm system of the regulator from the moment of its activation 11 Monitoring and signaling function of th...

Page 8: ...s on the display The next pressing of the S button confirms the willingness to make changes Then press the key to enter the access code and confirm with the S button After correct entry into the setti...

Page 9: ...tion chamber The regulator can control the cooling temperature in the range of 40 OC up to 120 OC In order to limit the scope of the control so as to prevent the user of the cooling device from settin...

Page 10: ...he regulator by pressing the 1 button also turns off the stirrer operation 7 2 2 Manually triggered stirrer operation The manual stirrer operation can be initiated by pressing the button marked by sym...

Page 11: ...not immediately stop the operation of the chiller The chiller restarts operation after the flap opening signal disappears taking into account the programmed minimum standstill time of the chiller 8 2...

Page 12: ...e function to work properly the appropriate temperature range must first be programmed this is parameter A1 temperature below which the alarm will be activated and parameter A2 temperature above which...

Page 13: ...temperature range is signaled only visually as shown in the figure above The alarm system audible and visual can also be turned off completely by changing the HA parameter to 1 see section 9 8 4 Temp...

Page 14: ...minimum standstill time of the chiller unit CF 0 00 inactive 0 00 active setting the time from 1 min to 60 min every 1 min 0 time after which the chiller unit is turned off after the flap of the milk...

Page 15: ...ling the control sensor CU every 0 2 OC scalable value setting the operation of the limit switch of opening the tank s flap UU 0 closing the limit switch raising the flap 1 opening the limit switch ra...