Makita WUT02U Instruction Manual Download Page 7

7 ENGLISH

Description of the lamp status

Refer to the below table for the meaning of the lamp status.

► 

Fig.9:

    

1.

 Wireless activation lamp 

2.

 Channel number indicator 

3.

 Caution lamp

Lamp

Status

Color

 

On

 

Blinking

Duration

Description

Wireless 

activation 

lamp

Standby

Blue

Adaptor: con

-

tinuing 

Tool: 2 hours

Waiting for the tool registration or the wireless 

activation function is available.

The lamp on the adaptor blinks when the stand-by 

switch on the vacuum cleaner is set to “AUTO” or 

equivalent.

The lamp on the tool blinks when the wireless 

activation button is pushed. The lamp on the tool 

will automatically turn off when no operation is 

performed for 2 hours.

When the tool is 

running.

The wireless activation of the vacuum cleaner is 

available and the tool is running.

Tool 

registration

Green

20 seconds

Ready for the tool registration. Searching the tool to 

be registered.

2 seconds

The tool registration has been finished. The wireless 

activation lamp will start blinking in blue.

Cancelling/

erasing 

tool 

registration

Red

 

(slow: 2 times/sec.)

20 seconds

Ready for the cancellation of the tool registration. 

Searching the tool to be cancelled.

 

(fast: 5 times/sec.)

When the 

wireless acti-

vation button is 

pressed down.

Ready to erase all tool registrations.

2 seconds

The tool registration has been cancelled/erased. 

The wireless activation lamp will start blinking in 

blue.

Others

Red

3 seconds

The power is supplied to the wireless unit and the 

wireless activation function is starting up.

Off

-

-

The stand-by switch on the vacuum cleaner is not 

set to “AUTO” or equivalent.

Channel 

number 

indicator

Channel 

number 

selection

Green

Continuing

The lighted channel number is selected.

Testing

Green

15 seconds

The adaptor is testing the communication to the 

vacuum cleaner through the selected channel 

number.

Caution 

lamp

Overheated 

or other 

trouble

Red

Continuing

The adaptor is overheated or in other trouble. 

Unplug the adaptor from the vacuum cleaner. Clean 

the vents on the adaptor and cool it down for a while 

and then check if it works properly.

If the adaptor does not work properly, contact our 

authorized service center for repairs.

Summary of Contents for WUT02U

Page 1: ...ONI PER L USO 22 NL Draadloos eenheidadapter GEBRUIKSAANWIJZING 29 ES Adaptador de Transmisión Inalámbrica MANUAL DE INSTRUCCIONES 36 PT Adaptador para Unidade de Comunicação sem Fio Wireless MANUAL DE INSTRUÇÕES 43 DA Trådløs enhedsadapter BRUGSANVISNING 49 EL Προσαρμογέας ασύρματης μονάδας ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ 55 TR Kablosuz Ünitesi Adaptörü KULLANMA KILAVUZU 62 ZHCN 蓝牙适配器 使用说明书 67 ...

Page 2: ...1 2 3 4 9 8 10 7 11 5 6 Fig 1 2 1 3 4 5 3 2 2 Fig 2 2 1 3 Fig 3 Fig 4 2 ...

Page 3: ...2 3 1 Fig 5 1 Fig 6 1 2 Fig 7 2 1 3 Fig 8 1 2 3 3 2 1 Fig 9 3 ...

Page 4: ...h wet hands Doing so may cause electric shock 5 Do not block the vents on the adaptor 6 Do not use the adaptor s cord for carrying and unplugging 7 Do not expose the wireless unit and the adap tor to rain or wet conditions Liquid come inside the appliance may cause malfunction and or electric shock 8 Do not use the wireless unit in places where the temperature exceeds 50 C 122 F 9 Do not operate t...

Page 5: ...precautions for handling the wireless unit refer to the instruction manual of the tool to be used with this adaptor Install the wireless units into the adaptor and tool as illustrated When inserting the wireless unit align the projections with the recessed portions on the slot Fig 2 1 Adaptor 2 Lid 3 Wireless unit 4 Projection 5 Recessed portion To remove the wireless unit open the lid slowly The ...

Page 6: ...level of the suction power is different from the setting on the vacuum cleaner 5 Push the channel setting button briefly to select another channel number 6 Hold the channel setting button for longer than 2 seconds for testing and check if the vacuum cleaner runs correctly If not repeat the step 5 to 6 again If the vacuum cleaner does not run in any of the channel number the vacuum cleaner may not ...

Page 7: ...art blinking in blue Cancelling erasing tool registration Red slow 2 times sec 20 seconds Ready for the cancellation of the tool registration Searching the tool to be cancelled fast 5 times sec When the wireless acti vation button is pressed down Ready to erase all tool registrations 2 seconds The tool registration has been cancelled erased The wireless activation lamp will start blinking in blue ...

Page 8: ...ng used Refer to Channel setting for how to configure Using a vacuum cleaner which is not supported Use a Makita cleaner with auto start stop function More than 10 tools are registered to the adaptor Perform the tool registration again If more than 10 tools are registered to the adap tor the tool registered earliest will be cancelled automatically The adaptor erased all tool registrations Perform ...

Page 9: ...nters always using Makita replacement parts OPTIONAL ACCESSORIES CAUTION These accessories or attachments are recommended for use with your Makita tool specified in this manual The use of any other accessories or attachments might present a risk of injury to persons Only use accessory or attachment for its stated purpose If you need any assistance for more details regard ing these accessories ask ...