background image

D

GB

F

NL

I

N

S

DK

SF

E

P

GR

TR

SLO

HR

SK

CZ

PL

H

RO

BG

RUS

EST

LV

LT

AL

MK

SR

UK

16

Makita VC3012L

When using an extension lead, check the minimum cross-sections of the cable:

Cable length

Cross section

< 16 A

< 25 A

up to 20 m

1,5 mm

2

2,5 mm

2

20 to 50 m

2,5 mm

2

4,0 mm

2

 Operation

Switch position

Function

I

On

0

Off

AUTO

Auto-On/Off

 Picking up liquids

Before liquids are picked up, always remove the filter bag. 

CAUTION – Check that the float works properly.

WARNING – If foam develops or liquid emerges, stop work immediately and empty the dirt tank. 

 Cleaning the filter element

If suction performance drops:
1.   Switching on the vacuum cleaner.
2.   Close the nozzles or suction hose opening with the palm of your hand.
3.   Press the button to start filter cleaning for at least three times for two seconds each. The resulting

stream of air removes attached dust from the slats of the filter elements.

4.  If the suction power is too low after filter cleaning: replace filter.

E

 Connecting electrical appliances

CAUTION! Follow the operating instructions and safety instructions for appliances connected to the 
power tool socket.

Use the socket on the vacuum cleaner for the purpose defined in the operating instructions only.

Before plugging an appliance into the appliance socket:
1.   Switch off the vacuum cleaner.
2.   Switch off the appliance to be connected.

F

 + 

G

 Maintenance, cleaning and repair

Only carry out maintenance work described in the operating instructions. Always pull out the mains 
plug before cleaning and maintenance of the vacuum cleaner. Never spray water on to the upper sec-
tion of the vacuum cleaner: Danger for persons, risk or short-circuiting.

The use of non-genuine spare parts and accessories can impair the safety of the appliance. Only use 
spare parts and accessories from Makita.

During maintenance and cleaning, handle the vacuum cleaner in such a manner that there is no dan-
ger for maintenance staff or other persons.

In the maintenance area

 

use filtered compulsory ventilation

 

wear protective clothing

 

clean the maintenance are so that no harmful substances get into the surroundings

During maintenance and repair work all contaminated parts that could not be cleaned satisfactorily 
must be

 

packed in well sealed bags 

 

disposed of in a manner that complies with valid regulations for such waste removal

Downloaded from 

www.Manualslib.com

 

manuals search engine

 

Summary of Contents for VC3012L

Page 1: ...ginal brugsanvisning Alkuper iset ohjeet Manual original Instru es de opera o original Orijinal talimatlar Izvirna navodila Izvorni upute R P vodn n vod na pou itie P vodn n vod k pou v n Instrukcja o...

Page 2: ...2 Makita VC3012L A 1 1 2 3 4 5 Downloaded from www Manualslib com manuals search engine...

Page 3: ...3 Makita VC3012L A 1 1 2 3 4 5 6 6 Downloaded from www Manualslib com manuals search engine...

Page 4: ...4 Makita VC3012L B 0 I auto 1 2 3 3 Downloaded from www Manualslib com manuals search engine...

Page 5: ...5 Makita VC3012L C 1 1 2 3 4 4 5 5 Downloaded from www Manualslib com manuals search engine...

Page 6: ...6 Makita VC3012L D 1 2 3x Filter Cleaning System 0 Push Clean Downloaded from www Manualslib com manuals search engine...

Page 7: ...7 Makita VC3012L E 5 1 2 3 4 Downloaded from www Manualslib com manuals search engine...

Page 8: ...8 Makita VC3012L F 1 2 3 3 4 5 6 Downloaded from www Manualslib com manuals search engine...

Page 9: ...9 Makita VC3012L G 1 2 3 3 4 5 6 7 8 8 Downloaded from www Manualslib com manuals search engine...

Page 10: ...e vacuum cleaner hot materials burning cigarettes hot ash etc flammable explosive aggressive liquids e g petrol solvents acids alkalis etc flammable explosive dust e g magnesium dust etc CAUTION The a...

Page 11: ...d to the power tool socket Use the socket on the vacuum cleaner for the purpose defined in the operating instructions only Before plugging an appliance into the appliance socket 1 Switch off the vacuu...

Page 12: ...formation Guarantee Our general conditions of business are applicable with regard to the guarantee Subject to change as a result of technical alterations Spare parts and accessories Description Order...

Page 13: ...hould not occur if the impedance at the transfer point is 0 15 For European countries only EC Declaration of Conformity Makita declares that the following Machine s Designation of the Machine Wet and...

Page 14: ...13 15 Volume flow air m h cfm 222 130 192 113 Vacuum mbar hPa inH2 O 250 250 100 230 230 92 Sound pressure level at a distance of 1 m ISO 3744 dB A 62 2 Sound level dB A 59 2 Hand arm vibration m s 2...