background image

C

ircuit  diagram

P 6/ 7

Color index of lead wires' sheath

Black
Red

White
Orange
Purple

Field 

viewed from

Commutator end

For Low voltage countries

Trigger

BHB

BHA

F/R Change

lever

[Housing 

L

 side]

[Housing 

R

 side]

Power supply cord

This Lead wire is 

blue 

for some

countries instead of white.

Switch

This Lead wire is 

brown

 for some

countries instead of black.

Insulated terminal (M3.5)

*AWG: American Wire Gauge

18 AWG*

18 AWG*

18 AWG*

18 AWG*

18 AWG*

18 AWG*

3

3

Non-insulated sleeve

Soldered

Soldered

Soldered

Soldered

スイッチ回路図

<正転時>

5

7

8

6

が導通

<逆転時>

5

6

8

7

が導通

5

6

7

8

L1 

N3 

3

Circuit of switch

Main swtich

Reversing switch

<Forward rotation>

continuity: 5-7, 8-6
<Reverse rotation>

continuity: 5-6, 8-7