ENGLISH (Original instructions)
SPECIFICATIONS
Model
LS1040 / LS1040S
Blade diameter
255 mm -260 mm
Blade body thickness
1.6 mm - 2.4 mm
Hole diameter
For all countries other than European countries
25.4 mm and 25 mm
For European countries
30 mm
Max. Cutting capacities (H x W) with blade 260 mm in diameter
Miter angle
Bevel angle
0°
45° (left and right)
93 mm x 95 mm
93 mm x 67 mm
0°
69 mm x 135 mm
69 mm x 95 mm
53 mm x 95 mm
49 mm x 67 mm
45° (left)
35 mm x 135 mm
35 mm x 94 mm
No load speed (min
-1
)
4,600
Dimensions (L x W x H)
530 mm x 476 mm x 532 mm
Net weight
12.4 kg
Safety class
/II
• Due to our continuing programme of research and development, the specifications herein are subject to change without notice.
• Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
END217-3
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
・
Read instruction manual.
・
DOUBLE
INSULATION
・
To avoid injury from flying debris, keep
holding the saw head down, after
making cuts, until the blade has come to
a complete stop.
・
Do not place hand or fingers close to the
blade.
・
For your safety, remove the chips, small
pieces, etc. from the table top before
operation.
・
Always set SUB-FENCE to left position
when performing left bevel cuts. Failure
to do so may cause serious injury to
operator.
・
To loosen the bolt, turn it clockwise.
・
Only for EU countries
Do not dispose of electric equipment
together with household waste material!
In observance of European Directive
2002/96/EC on waste electric and
electronic equipment and its
implementation in accordance with
national law, electric equipment that
have reached the end of their life must
be collected separately and returned to
an environmentally compatible recycling
facility.
ENE004-1
Intended use
The tool is intended for accurate straight and miter
cutting in wood. With appropriate saw blades, aluminum
can also be sawed.
ENF002-2
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and can
only be operated on single-phase AC supply. They are
double-insulated and can, therefore, also be used from
sockets without earth wire.
For Model LS1040
ENF100-1
For public low-voltage distribution systems of
between 220 V and 250 V.
Switching operations of electric apparatus cause voltage
fluctuations. The operation of this device under
unfavorable mains conditions can have adverse effects
to the operation of other equipment. With a mains