background image

8 ENGLISH

14. 

During and after use, the battery cartridge may 

take on heat which can cause burns or low 

temperature burns. Pay attention to the han-

dling of hot battery cartridges.

15. 

Do not touch the terminal of the tool imme-

diately after use as it may get hot enough to 

cause burns.

16. 

Do not allow chips, dust, or soil stuck into the 

terminals, holes, and grooves of the battery 

cartridge.

 It may cause heating, catching fire, 

burst and malfunction of the tool or battery car

-

tridge, resulting in burns or personal injury.

17. 

Unless the tool supports the use near 

high-voltage electrical power lines, do not use 

the battery cartridge near a high-voltage elec-

trical power lines.

 It may result in a malfunction 

or breakdown of the tool or battery cartridge.

18. 

Keep the battery away from children.

SAVE THESE INSTRUCTIONS.

CAUTION:

 

Only use genuine Makita batteries.

 

Use of non-genuine Makita batteries, or batteries that 

have been altered, may result in the battery bursting 

causing fires, personal injury and damage. It will 

also void the Makita warranty for the Makita tool and 

charger.

Tips for maintaining maximum 

battery life

1. 

Charge the battery cartridge before completely 

discharged. Always stop tool operation and 

charge the battery cartridge when you notice 

less tool power.

2. 

Never recharge a fully charged battery car-

tridge. Overcharging shortens the battery 

service life.

3. 

Charge the battery cartridge with room tem-

perature at 10 °C - 40 °C (50 °F - 104 °F). Let 

a hot battery cartridge cool down before 

charging it.

4. 

When not using the battery cartridge, remove 

it from the tool or the charger.

5. 

Charge the battery cartridge if you do not use 

it for a long period (more than six months). 

Important safety instructions for 

wireless unit

1. 

Do not disassemble or tamper with the wire-

less unit.

2. 

Keep the wireless unit away from young chil-

dren. If accidentally swallowed, seek medical 

attention immediately.

3. 

Use the wireless unit only with Makita tools.

4. 

Do not expose the wireless unit to rain or wet 

conditions.

5. 

Do not use the wireless unit in places where 

the temperature exceeds 50 °C (122 °F).

6. 

Do not operate the wireless unit in places 

where medical instruments, such as heart 

pace makers are nearby.

7. 

Do not operate the wireless unit in places 

where automated devices are nearby.

 If oper-

ated, automated devices may develop malfunction 

or error.

8. 

Do not operate the wireless unit in places 

under high temperature or places where 

static electricity or electrical noise could be 

generated.

9. 

The wireless unit can produce electromagnetic 

fields (EMF) but they are not harmful to the 

user.

10. 

The wireless unit is an accurate instrument. Be 

careful not to drop or strike the wireless unit.

11. 

Avoid touching the terminal of the wireless 

unit with bare hands or metallic materials.

12. 

Always remove the battery on the product 

when installing the wireless unit into it.

13. 

When opening the lid of the slot, avoid the 

place where dust and water may come into the 

slot. Always keep the inlet of the slot clean.

14. 

Always insert the wireless unit in the correct 

direction.

15. 

Do not press the wireless activation button 

on the wireless unit too hard and/or press the 

button with an object with a sharp edge.

16. 

Always close the lid of the slot when 

operating.

17. 

Do not remove the wireless unit from the slot 

while the power is being supplied to the tool.

 

Doing so may cause a malfunction of the wireless 

unit.

18. 

Do not remove the sticker on the wireless unit.

19. 

Do not put any sticker on the wireless unit.

20. 

Do not leave the wireless unit in a place where 

static electricity or electrical noise could be 

generated.

21. 

Do not leave the wireless unit in a place sub-

ject to high heat, such as a car sitting in the 

sun.

22. 

Do not leave the wireless unit in a dusty or 

powdery place or in a place corrosive gas 

could be generated.

23. 

Sudden change of the temperature may bedew 

the wireless unit. Do not use the wireless unit 

until the dew is completely dried. 

24. 

When cleaning the wireless unit, gently wipe 

with a dry soft cloth. Do not use benzine, thin-

ner, conductive grease or the like.

25. 

When storing the wireless unit, keep it in the 

supplied case or a static-free container.

26. 

Do not insert any devices other than Makita 

wireless unit into the slot on the tool.

27. 

Do not use the tool with the lid of the slot dam-

aged.

 Water, dust, and dirt come into the slot may 

cause malfunction.

28. 

Do not pull and/or twist the lid of the slot more 

than necessary.

 Restore the lid if it comes off 

from the tool.

29. 

Replace the lid of the slot if it is lost or 

damaged.

SAVE THESE INSTRUCTIONS.

Summary of Contents for HS012GZ

Page 1: ...INSTRUCTION MANUAL Cordless Circular Saw HS012G ENGLISH Original instructions Read before use ...

Page 2: ...n the equipment waste electrical and electronic equipment accumulators and batteries may have a negative impact on the environment and human health Do not dispose of electrical and electronic appliances or batteries with household waste In accordance with the European Directive on waste electrical and electronic equip ment and on accumulators and batteries and waste accumulators and batteries as w...

Page 3: ...rk areas invite accidents 2 Do not operate power tools in explosive atmo spheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes 3 Keep children and bystanders away while operating a power tool Distractions can cause you to lose control Electrical safety 1 Power tool plugs must match the outlet Never modify the plug in any way...

Page 4: ...t may affect the power tool s operation If dam aged have the power tool repaired before use Many accidents are caused by poorly maintained power tools 6 Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control 7 Use the power tool accessories and tool bits etc in accordance with these instructions tak ing into a...

Page 5: ...ation Kickback causes and related warnings kickback is a sudden reaction to a pinched jammed or misaligned saw blade causing an uncontrolled saw to lift up and out of the workpiece toward the operator when the blade is pinched or jammed tightly by the kerf closing down the blade stalls and the motor reaction drives the unit rapidly back toward the operator if the blade becomes twisted or misaligne...

Page 6: ...ebris 3 The lower guard may be retracted manually only for special cuts such as plunge cuts and compound cuts Raise the lower guard by the retracting handle and as soon as the blade enters the material the lower guard must be released For all other sawing the lower guard should operate automatically 4 Always observe that the lower guard is cover ing the blade before placing the saw down on bench o...

Page 7: ...ing time has become excessively shorter stop operating immediately It may result in a risk of overheating possible burns and even an explosion 4 If electrolyte gets into your eyes rinse them out with clear water and seek medical atten tion right away It may result in loss of your eyesight 5 Do not short the battery cartridge 1 Do not touch the terminals with any con ductive material 2 Avoid storin...

Page 8: ...akers are nearby 7 Do not operate the wireless unit in places where automated devices are nearby If oper ated automated devices may develop malfunction or error 8 Do not operate the wireless unit in places under high temperature or places where static electricity or electrical noise could be generated 9 The wireless unit can produce electromagnetic fields EMF but they are not harmful to the user 1...

Page 9: ...tically cuts off power to the motor to extend tool and battery life The tool will auto matically stop during operation if the tool or battery is placed under one of the following conditions Overload protection When the tool battery is operated in a manner that causes it to draw an abnormally high current the tool automatically stops In this situation turn the tool off and stop the application that...

Page 10: ...to a Makita service center for proper repairs BEFORE further usage To prevent the switch trigger from being accidentally pulled a lock off button is provided To start the tool depress the lock off button and pull the switch trigger Release the switch trigger to stop 1 2 Fig 9 1 Switch trigger 2 Lock off button NOTICE Do not pull the switch trigger hard without pressing in the lock off button This ...

Page 11: ...g For straight cuts align the 0 position on the front of the base with your cutting line For 45 bevel cuts align the 45 position with it 1 2 Fig 13 1 Cutting line 0 position 2 Cutting line 45 position Lighting the lamp CAUTION Do not look in the light or see the source of light directly To turn on the lamp without running the tool pull the switch trigger without pressing the lock off button To tur...

Page 12: ...kly stop the circular saw blade after switch lever release have tool serviced at a Makita service center CAUTION The blade brake system is not a substitute for blade guard NEVER USE TOOL WITHOUT A FUNCTIONING BLADE GUARD SERIOUS PERSONAL INJURY CAN RESULT Electronic function The tools equipped with electronic function are easy to operate because of the following feature s Soft start feature Soft s...

Page 13: ...flange 6 Arrow on the tool For tool with the ring 1 2 3 4 5 6 7 Fig 20 1 Hex bolt 2 Outer flange 3 Circular saw blade 4 Arrow on the circular saw blade 5 Ring 6 Inner flange 7 Arrow on the tool 4 Press the shaft lock and tighten the hex bolt For tool with the inner flange for other than 15 88 mm hole diameter saw blade The inner flange has a certain diameter protrusion on one side of it and a diff...

Page 14: ...r mounting of the blade causing blade movement and severe vibration resulting in possible loss of control during operation and in seri ous personal injury Removing circular saw blade 1 Loosen the lever on the depth guide and move the base down 2 Press the shaft lock fully so that the mounting shaft cannot revolve and use the hex wrench to loosen the hex bolt Then remove the hex bolt outer flange c...

Page 15: ... temperature Then the tool can work to its full capacity Fig 27 Hold the tool firmly The tool is provided with both a front grip and rear handle Use both to best grasp the tool If both hands are holding saw they cannot be cut by the circular saw blade Set the base on the workpiece to be cut without the circular saw blade making any contact Then turn the tool on and wait until the circular saw blad...

Page 16: ... flat and stable surface when installing the wireless unit NOTICE Clean the dust and dirt on the tool before installing the wireless unit Dust or dirt may cause malfunction if it comes into the slot of the wireless unit NOTICE To prevent the malfunction caused by static touch a static discharging material such as a metal part of the tool before picking up the wireless unit NOTICE When installing t...

Page 17: ...beforehand 1 Install the batteries to the vacuum cleaner and the tool 2 Set the stand by switch on the vacuum cleaner to AUTO 1 Fig 33 1 Stand by switch 3 Press the wireless activation button on the vac uum cleaner for 3 seconds until the wireless activation lamp blinks in green And then press the wireless acti vation button on the tool in the same way 1 1 2 2 Fig 34 1 Wireless activation button 2...

Page 18: ...ctivation lamp 5 Turn on the tool Check if the vacuum cleaner runs while the tool is operating To stop the wireless activation of the vacuum cleaner push the wireless activation button on the tool NOTE The wireless activation lamp on the tool will stop blinking in blue when there is no operation for 2 hours In this case set the stand by switch on the vacuum cleaner to AUTO and push the wireless ac...

Page 19: ...vacuum cleaner is available and the tool is running Tool registration Green 20 seconds Ready for the tool registration Waiting for the registration by the vacuum cleaner 2 seconds The tool registration has been finished The wireless activation lamp will start blinking in blue Cancelling tool registration Red 20 seconds Ready for the cancellation of the tool registration Waiting for the cancellatio...

Page 20: ...nd then become red After that press the wireless activation button on the tool in the same way 1 1 2 2 Fig 40 1 Wireless activation button 2 Wireless activation lamp If the cancellation is performed successfully the wire less activation lamps will light up in red for 2 seconds and start blinking in blue NOTE The wireless activation lamps finish blinking in red after 20 seconds elapsed Press the wi...

Page 21: ... the power button on the vacuum cleaner is turned on Push the wireless activation button briefly and perform the tool registration cancellation procedures again The tool registration procedures for the tool or vacuum cleaner have not finished Perform the tool registration procedures for both the tool and the vacuum cleaner at the same timing Radio disturbance by other appliances which generate hig...

Page 22: ...e plate 2 Make the base perpendicular to the blade using a triangular rule or square rule by turning the adjusting screw 1 2 3 Fig 41 1 Triangular rule 2 Adjusting screw 3 Lever 3 Tighten the lever and then make a test cut to check the verticalness Adjusting the parallelism This adjustment has been made at the factory But if it is off you can adjust it as the following procedure 1 Set the tool to ...

Page 23: ...23 ...

Page 24: ...www makita com Makita Europe N V Makita Corporation 3 11 8 Sumiyoshi cho Anjo Aichi 446 8502 Japan Jan Baptist Vinkstraat 2 3070 Kortenberg Belgium 885A10 228 EN 20220930 ...

Reviews: