8 ENGLISH
FUNCTIONAL
DESCRIPTION
CAUTION:
Always be sure that the tool is
switched off and unplugged before adjusting or
checking function on the tool.
Shaft lock
Press the shaft lock to prevent spindle rotation when
installing or removing accessories.
1
Fig.1
►
1.
Shaft lock
NOTICE:
Never actuate the shaft lock when the
spindle is moving.
The tool may be damaged.
Switch handle mounting positions
Only for model GA7080 / GA9080
CAUTION:
Always make sure that the switch
handle is locked in the desired position before
operation.
The switch handle can be rotated to either 90° left or
right to fit your work needs. First, unplug the tool. Press
the lock button and rotate the switch handle to left
or right fully. The switch handle will be locked in that
position.
1
2
3
Fig.2
►
1.
Motor housing
2.
Lock button
3.
Handle
Switch action
CAUTION:
Before plugging in the tool, always
check to see that the switch trigger actuates
properly and returns to the "OFF" position when
released.
CAUTION:
Make sure to switch off the tool in
case of a blackout or accidental shut down such
as unplugging of the power cord.
Otherwise the
tool will start unexpectedly when the power supply
is recovered and cause an accident or personal injury.
There are three patterns of the switch action depending
on country.
A
B
C
2
1
Fig.3
►
1.
Switch trigger
2.
Lock lever
For tool with the lock-on switch
Country specific
CAUTION:
Switch can be locked in "ON" posi-
tion for ease of operator comfort during extended
use. Apply caution when locking tool in "ON"
position and maintain firm grasp on tool.
To start the tool, simply pull the switch trigger (in the B
direction). Release the switch trigger to stop.
For continuous operation, pull the switch trigger (in the
B direction) and then push in the lock lever (in the A
direction).
To stop the tool from the locked position, pull the switch
trigger fully (in the B direction), then release it.
For tool with the lock-off switch
Country specific
To prevent the switch trigger from accidentally pulled, a
lock lever is provided.
To start the tool, push in the lock lever (in the A direc-
tion) and then pull the switch trigger (in the B direction).
Release the switch trigger to stop.
NOTICE:
Do not pull the switch trigger hard
without pressing in the lock lever.
This can cause
switch breakage.
Summary of Contents for GA9080