Make sure that the appliance is switched OFF before connecting it to the generator.

Do not move the generator while it is running.

Be sure to ground the generator if the connected appliance is grounded. Failure to
ground unit may lead to electrical shock.

WARNING

2. USING ELECTRIC POWER

(1) CONTROL PANEL

1

2

6

3

5

1

2

6

3

4

5

q

PILOT LAMP

w

AC CIRCUIT BREAKER

e

AC RECEPTACLES (20A)

r

AC RECEPTACLES (30A)

t

GROUND TERMINAL

y

ENGINE SWITCH

G2800L / G3200L

G4300L

CONTROL PANEL

(2) AC APPLICATION (See Fig. 

4

4

-

q

q

,

w

w

)

(a) Make sure the pilot lamp is turned on.

(b) Turn off the switch(es) of the electrical appliance(s) before connecting to the generator.

(c) Insert the plug(s) of the electrical appliance(s) into the receptacle. (See Fig. 

4

-

q

)

G2800L(US)_GU1843  2004.2.6  1:14 PM  ページ7

Summary of Contents for G4300L

Page 1: ...urability period Depending on the size of the engine a selection of time periods can be used to measure the Air Index level see below Descriptive Term Applicable to Emissions Durability Period Moderate 50 hours engine from 0 to 65 cc 125 hours engine greater than 65 cc Intermediate 125 hours engine from 0 to 65 cc 250 hours engine greater than 65 cc Extended 300 hours engine from 0 to 65 cc 500 ho...

Page 2: ... Service Center or Service Center authorized by MAKITA during a warranty repair alteration accident failure to use the recommended fuel and oil or not performing required maintenance services The replacement parts used for required maintenance services Consequential damages such as loss of time inconvenience loss of use of the engine or equipment etc Diagnosis and inspection charges that do not re...

Page 3: ...ompano Beach FL 33064 954 781 6333 GEORGIA 4680 River Green Parkway NW Duluth GA 30096 770 476 8911 ILLINOIS 1450 Feehanville Dr Mt Prospect IL 60056 6011 847 297 3100 MARYLAND 7397 Washington Boulevard Suite 104 Elkridge MD 21075 410 796 4401 MASSACHUSETTS 232 Providence Highway Westwood MA 02090 781 461 9754 MINNESOTA 6427 Penn Ave South Richfield MN 55423 612 869 5199 MISSOURI 9876 Watson Rd St...

Page 4: ...quent purchaser that the engine is free from defect in material and workmanship that can cause the failure of a warranted emission related part WHAT IS COVERED UNDER THIS WARRANTY Repair and or replacement of any warranted emission related part will be performed at no charge provided the work is performed at an authorized warranty station There will also be no charge for any diagnostic labor perfo...

Page 5: ...eaner element Every 200 hours 4 Clean and adjust spark plug and electrodes Every 200 hours Note More frequent maintenance may be necessary under dusty dirty or severe conditions REPAIR AND REPLACEMENT OF EMISSION RELATED PARTS It is recommended that only engine replacement parts which have been authorized and approved by MAKITA should be used in the performance of any warranty maintenance or repai...

Page 6: ...G2800L US _GU1843 2004 2 6 1 14 PM ページ06 ...

Page 7: ...n ordering spare parts always give us the MODEL PRODUCTION NUMBER PROD No and SERIAL NUMBER SER No of your Product Please fill in the following blanks after checking the production number on your product Location of label is different depending on the product model CONTENTS 1 SAFETY PRECAUTIONS 2 2 COMPONENTS 5 3 PRE OPERATION CHECKS 5 4 OPERATING PROCEDURES 6 5 WATTAGE INFORMATION 9 6 SPARK ARRES...

Page 8: ...ase piston seizure may occur even if the oil is above the upper level WARNING Pay attention to the wiring or extension cords from the generator to the connected device If the wire is under the generator or in contact with a vibrating part it may break and possibly cause a fire generator burnout or electric shock hazard Replace damaged or worn cords immediately WARNING Do not operate the generator ...

Page 9: ...ll bystanders at a safe distance from work areas WARNING If wet wipe and dry it well before starting Do not pour water directly over the generator nor wash it with water WARNING Be extremely careful that all necessary electrical grounding procedures are followed during each and every use Failure to do so can be fatal WARNING It is absolutely essential that you know the safe and proper use of the p...

Page 10: ...r lines Engine oil ON power and Engine Add oil Battery charging condition OFF power and Engine Alternating current Direct current Plus positive polarity Minus negative polarity OUT position of a bistable push control IN position of a bistable push control Protective earth ground Fuse Choke cold starting aid Engine start Electric start Engine stop Diesel fuel Fast Slow P r Rated power kW COP Contin...

Page 11: ...omotive gasoline Be sure to use the fuel filter screen on the fuel filter neck See Fig 2 e q FUEL FILTER SCREEN w TANK CAP Fuel tank capacity G2800L 10 8 liters G3200L 10 8 liters G4300L 12 8 liters Recommended engine oil Use 4 stroke automotive detergent oil of API service class SE or higher grade SG SH or SJ is recommended SAE 10W 30 or 10W 40 is recommended for general all temperature use If si...

Page 12: ...e sure the appliance is disconnected b Turn engine switch to CHOKE position When engine is warm or temperature is high start engine with the switch at RUN position See Fig 3 q q STOP w CHOKE c Pull the starter handle slowly until passing the compression point resistance will be felt then return the handle to its original position and pull briskly See Fig 3 w q RECOIL STARTER HANDLE w PULL BRISKLY ...

Page 13: ... WARNING 2 USING ELECTRIC POWER 1 CONTROL PANEL 1 2 6 3 5 1 2 6 3 4 5 q PILOT LAMP w AC CIRCUIT BREAKER e AC RECEPTACLES 20A r AC RECEPTACLES 30A t GROUND TERMINAL y ENGINE SWITCH G2800L G3200L G4300L CONTROL PANEL 2 AC APPLICATION See Fig 4 4 q q w w a Make sure the pilot lamp is turned on b Turn off the switch es of the electrical appliance s before connecting to the generator c Insert the plug ...

Page 14: ...ller cap on the opposite side of carburetor CAUTION d Turn on the switch of the appliance NOTE When the no fuse breaker turns off during operation the generator is over loaded or the appliance is defective Stop the generator immediately check the appliance and or generator for overloading and have repaired as necessary by Makita factory or authorized service center Up to 20A Style Ampere NEMA 5 20...

Page 15: ...f the wattage to continue running Most electrical tools require 1 2 to 3 times their wattage for running under load during use For example a 5000 watt generator can power a 1800 to 4000 watt electrical tool Loads such as submersible pumps and air compressors require a very large force to start They need 3 to 5 times the normal running wattage in order to start For example a 5000 watt generator wou...

Page 16: ... 1 5V 2 5V 4V 5V 6 5V 7 5V 5 5 10 to 8 35 70 0 32 0 332 1V 2V 2 5V 3 5V 4V 5V VOLTAGE DROP IN ELECTRIC EXTENSION CORDS When a long electric extension cord is used to connect an appliance or tool to the generator a certain amount of voltage drop or loss occurs in the extension cord which reduces the effective voltage available for the appliance or tool The chart below has been prepared to illustrat...

Page 17: ...very hot Allow the muffler to cool before cleaning the spark arrester How to remove the spark arrester 1 Remove the flange bolts from the muffler cover and remove the muffler cover 2 Remove the special screw from the spark arrester and remove the spark arrester from the muffler SPARK ARRESTER SCREEN MUFFLER TAIL SCREEN TAIL SCREEN COVER SCREW Clean the spark arrester screen Use a brush to remove c...

Page 18: ...Y FOR THE USER OF THIS GENERATOR TO CONDUCT THE MAINTENANCE AND ADJUSTMENTS ON THE EMISSION RELATED PARTS LISTED BELOW TO KEEP THE EMISSION CONTROL SYSTEM EFFECTIVE The emission control system consists of the following parts The maintenance schedule indicated in the table is based on the normal generator operation Should the generator be operated in extremely dusty condition or in heavier loading ...

Page 19: ... CLEAN AND ADJUST SPARK PLUG AND ELECTRODES REPLACE SPARK PLUG Note 1 Initial oil change should be performed after first twenty 20 hours of operation Thereafter change oil every hundred 100 hours Before changing oil check for a suitable way to dispose of old oil Do not pour it down into sewage drains onto garden soil or into open streams Your local zoning or environmental regulations will give you...

Page 20: ...GB GB GB GB GB GB GB GB 8 HOW TO MAINTENANCE See Fig 5 5 1 ENGINE OIL CHANGE See Fig 5 5 q q Change engine oil every 50 hours For new engine change oil after 20 hours a Drain oil by removing the drain plug and the oil filler cap while the engine is warm q OIL DRAIN PLUG b Reinstall the drain plug and fill the engine with oil until it reaches the upper level on the oil filler cap Use fresh and high...

Page 21: ...TING When No Electricity Is Generated at Receptacle When Engine Fails to Start Check if engine switch is in its proper position Check fuel level Check to make sure generator is not connected to an appliance Check spark plug for contamination Check engine oil level Check spark plug for loose spark plug cap Turn engine switch to CHOKE position If empty refill fuel tank making sure not to overfill If...

Page 22: ...al 10 8 2 9 Rated continuous operation Approx hours Starting system Recoil Dimension Length mm in 537 21 1 Width mm in 432 17 0 High mm in 475 18 7 Dry weight kg lb 43 94 8 EX27 EX21 55 121 3 48 105 8 G4300L G3200L US GB GB GB GB GB GB GB GB GB GB GB GB GB GB GB 4 3 3 7 3 2 2 7 265 212 580 22 8 477 18 8 508 20 0 Valve Clearance Intake Exhaust mm in 0 1 0 03 0 0039 0 0012 Note Adjust the valve clea...

Page 23: ...Blu Light blue Brn Brown Brn W Brown White Grn Green Grn W Green White Org Orange Gry Gray R Red W White Y Yellow Grn Y Green Yellow W Blk White Black Pur Purple Main coil 1 Main coil 2 AC circuit breaker Pilot lamp PL ENGINE AVR Field Winding Brush Brush Exciter coil Ignition coil Stop switch Spark plug Oil sensor control unit Oil sensor Blk Blk AC receptacle 120V G2800L US _GU1843 2004 2 6 1 14 ...

Page 24: ...wn Brn W Brown White Grn Green Grn W Green White Org Orange Gry Gray R Red W White Y Yellow Grn Y Green Yellow W Blk White Black Pur Purple Main coil 1 Main coil 2 AC circuit breaker Pilot lamp PL ENGINE AVR Field Winding Brush Brush Exciter coil Ignition coil Stop switch Spark plug Oil sensor control unit Oil sensor Blk Blk AC receptacle 120V AC receptacle 120V G2800L US _GU1843 2004 2 6 1 14 PM ...

Reviews: