15
−
ENGLISH
TABLE 1
NOTE :
When the
AC circuit breaker turns off during operation, the generator is over
loaded or the appliance is defective. Stop the generator immediately, check the
appliance and / or generator for overloading or detect and have repaired as
necessary by Makita factory or authorized service center.
■
To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn
it clockwise to the lock position.
■
Be sure to ground the generator if
the connected electrical device Is
grounded.
WARNING
TWIST
up to 30A
up to 20A
NEMA
5-20R
NEMA
L14-30R
NEMA
5-20P
NEMA
L14-30P
GFCI (Ground Fault
Circuit Interrupter)
Receptacle, duplex
(REC1)
Locking Receptacle
(REC4)
Style
Ampere
Receptacle
AC plug
Description
up to 30A
NEMA
L5-30R
NEMA
L5-30P
Locking Receptacle
(REC3)
The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit
Interrupter). GFCI shuts off the output current from the duplex 120V
receptacle when a ground fault occurs in the generator or the appliance.
Please note that other receptacles are not protected by GFCI.
[