1. Safety measures

Carefully read the operating instructions before assembling
and starting. The appliance must not be used by persons
who are not thoroughly acquainted with the instructions
handbook (operating instructions). Children and persons
under the age of 16 cannot use the pump and must be
kept well away from the appliance when it is connected.
The user is liable towards third parties in the area where
the appliance is in operation.

While the pump is operating persons must
not be in the liquid to be pumped.
The  pump  may  be  connected  only  by

means of a safety switch for fault currents, with
a rated opening current up to 30 mA and a socket
with an earth contact installed in conformity with
the regulations.
Protection: at least 10 Amps.
Operation in swimming pools and garden ponds is
admitted.
For other operation, the provisions in conformity with
the standard VDE 0100 part 702 must be respected.

CAUTION: Before checking, connect the pump and
the system with no voltage!
Replacing  the  line  connecting  up  with  the  mains
requires using special tools and therefore may be
done only by the manufacturer or its service engineers.

The pump may operate only with a pipe connecting
the appliance (extension) that is no lighter than a
rubber hose mod. H07 RNF in conformity with the DIN
57282 or DIN 57245 standard.

(For your safety)
The voltage (230 Volts alternating current) indi-
cated on the pump’s rating plate must correspond

to the available mains voltage.
Before starting it is necessary to make sure by having a
check made by qualified personnel that there are the
necessary electrical protection measures.
•  Earth connection.
•  Earthed neutral.
• The safety switch for fault currents corresponds to the

safety regulations of the electricity board and functions
perfectly.

• Plug connections must be protected from water. If there

is a risk of flooding, plug connections must be placed
somewhere safe.

• Definitely avoid pumping aggressive liquids and abrasive

products.

In the event of the pump failing, repair work may only be
carried  out  by  the  repair  workshops  of  the  technical
service. Only genuine spare parts must be used.

SUBMERSIBLE PUMP

18

It is notified that in conformity with the law on product
liability

we cannot be held responsible

for the damage caused by our appliance:
a) because of improper repairs not carried out by the

personnel of the assistance points authorized by us;

b) or if GENUINE SPARE PARTS are not used to replace

parts;

c) or if the indications and provisions given in the instruc-

tions handbook are not complied with.
The same provisions hold for the accessories.

Resistance

The maximum temperature of the delivery liquid should
never 35

°

C in continuous operation.

Infiammable, combustible or explosive liquids cannot
be conveyed with this pump!
In particular, do not use engine fuels, detergents, or other
chemical products.

2. Use

CAUTION! Sector of use

“DRAINAGE” – To transfer and empty fresh to
slightly polluted water from rainwater barrels and
casks.

“VORTEX” – Portable submersible pump for
discharge and waste water with solids in suspen-
sion.
Also used as emergency pump, in case of over-
flowing with muddy water, thanks to its large
suction filter.

To  achieve  excellent  motor  cooling  the  pump
casing is provided with a breather hole that enables
water to flow out.
The pump must be protected from running dry.

Starting

First  put  the  pump  into  water  and  then
connect the plug.
The pump is ready for use.

3. Before starting

Installation of your canned motor pump is:
• fixed with a fixd pipe, or
• fixed with a flexible hose.

Take care
When installing it is necessary to take care that the pump
is never fitted hanging from its delivery pipe, but is always
placed in a raised position with respect to the bottom of

the well so that the muddy bottom is not sucked up with
the water.
Never handle or hang the pump by gripping the power
supply cable.
In pumps with a floating switch, the latter is adjusted in
order to make immediate starting possibile.

Note
The  pump  well  must  have  minimum  dimensions  of
40x40x50 cm. so that the floating switch can move freely.
It is also possible to use round, prefabricated concrete
wells with an inner diameter of approx. 40 cm.

4. Maintenance instructions

Your canned motor pump is a quality product, free from
maintenance. It has been subjected to rigorous final
checks.
However, for a long service life and continuous operation,
we recommend constant care and regular checks.

Before every maintenance job, disconnect the plug.

• F

or transportable use the pump should be washed with

clear water after every use.

• F

or fixed installation it is recommended to check the

operation of the floating switch every 3 months.

Using a jet of water, get rid of the fibre and spindly

particles that may get deposited in the pump’s cassing.

In the event of excessive deposits in the pump cassing,
dismantle the inlet filter by unscrewing the star screw.
Wash the pump casing and fit the inlet filter back on.

• E

very 3 months remove the mud from the bottom and

walls of the well.

• Eliminate the deposits from the floating switch, washing

it with fresh water.

Protect the pump from frost.

CAUTION!

“DRAINAGE”
Special instructions: It is not suitable for pumping:
sewage, sandy water.
The pump must never run dry.
The manufacturer’s warranty is null and void in
the event of damage to the pump caused by it
running dry.

“VORTEX”
The pump must never run dry.
The manufacturer’s warranty is null and void in
the event of damage to the pump caused by it
running dry.

CAUSES

The motor will not work

The motor works, the pump will not convey

Insufficient flow rate

Repeated switching off with disconnection of the protection switch

TROUBLE

No mains voltage, the floating swittch will not connect
Defective protection device
Motor protection disconnected, pump straining/blocked
Dry operation protection disconnected, the water level has fallen too much
Defective pump

Clogged suction opening
Check valve blocked or delivery pipe bent
Delivery pipe clogged

F

oreign bodies in the pump, pump impeller blocked

The pump runs dry

If it is not possibile to eliminate the trouble, please call our service department.

To avoid damage during transport, please ship in the ORIGINAL PACKING.

Troubleshooting Table

19

1. Safety measures

Carefully read the operating instructions before assembling
and starting. The appliance must not be used by persons
who are not thoroughly acquainted with the instructions
handbook (operating instructions). Children and persons
under the age of 16 cannot use the pump and must be
kept well away from the appliance when it is connected.
The user is liable towards third parties in the area where
the appliance is in operation.

While the pump is operating persons must
not be in the liquid to be pumped.
The  pump  may  be  connected  only  by

means of a safety switch for fault currents, with
a rated opening current up to 30 mA and a socket
with an earth contact installed in conformity with
the regulations.
Protection: at least 10 Amps.
Operation in swimming pools and garden ponds is
admitted.
For other operation, the provisions in conformity with
the standard VDE 0100 part 702 must be respected.

CAUTION: Before checking, connect the pump and
the system with no voltage!
Replacing  the  line  connecting  up  with  the  mains
requires using special tools and therefore may be
done only by the manufacturer or its service engineers.

The pump may operate only with a pipe connecting
the appliance (extension) that is no lighter than a
rubber hose mod. H07 RNF in conformity with the DIN
57282 or DIN 57245 standard.

(For your safety)
The voltage (230 Volts alternating current) indi-
cated on the pump’s rating plate must correspond

to the available mains voltage.
Before starting it is necessary to make sure by having a
check made by qualified personnel that there are the
necessary electrical protection measures.

•  Earth connection.
•  Earthed neutral.

The safety switch for fault currents corresponds to the
safety regulations of the electricity board and functions
perfectly.

Plug connections must be protected from water. If there
is a risk of flooding, plug connections must be placed
somewhere safe.

Definitely avoid pumping aggressive liquids and abrasive
products.

In the event of the pump failing, repair work may only be
carried  out  by  the  repair  workshops  of  the  technical
service. Only genuine spare parts must be used.

SUBMERSIBLE PUMP

18

It is notified that in conformity with the law on product
liability

we cannot be held responsible

for the damage caused by our appliance:
a) because of improper repairs not carried out by the

personnel of the assistance points authorized by us;

b) or if GENUINE SPARE PARTS are not used to replace

parts;

c) or if the indications and provisions given in the instruc-

tions handbook are not complied with.
The same provisions hold for the accessories.

Resistance

The maximum temperature of the delivery liquid should
never 35

°

C in continuous operation.

Infiammable, combustible or explosive liquids cannot
be conveyed with this pump!
In particular, do not use engine fuels, detergents, or other
chemical products.

2. Use

CAUTION! Sector of use

“DRAINAGE” – To transfer and empty fresh to
slightly polluted water from rainwater barrels and
casks.

“VORTEX” – Portable submersible pump for
discharge and waste water with solids in suspen-
sion.
Also used as emergency pump, in case of over-
flowing with muddy water, thanks to its large
suction filter.

To  achieve  excellent  motor  cooling  the  pump
casing is provided with a breather hole that enables
water to flow out.
The pump must be protected from running dry.

Starting

First  put  the  pump  into  water  and  then
connect the plug.
The pump is ready for use.

3. Before starting

Installation of your canned motor pump is:

• fixed with a fixd pipe, or
• fixed with a flexible hose.

Take care
When installing it is necessary to take care that the pump
is never fitted hanging from its delivery pipe, but is always
placed in a raised position with respect to the bottom of

the well so that the muddy bottom is not sucked up with
the water.
Never handle or hang the pump by gripping the power
supply cable.
In pumps with a floating switch, the latter is adjusted in
order to make immediate starting possibile.

Note
The  pump  well  must  have  minimum  dimensions  of
40x40x50 cm. so that the floating switch can move freely.
It is also possible to use round, prefabricated concrete
wells with an inner diameter of approx. 40 cm.

4. Maintenance instructions

Your canned motor pump is a quality product, free from
maintenance. It has been subjected to rigorous final
checks.
However, for a long service life and continuous operation,
we recommend constant care and regular checks.

Before every maintenance job, disconnect the plug.

• F

or transportable use the pump should be washed with

clear water after every use.

• F

or fixed installation it is recommended to check the

operation of the floating switch every 3 months.

Using a jet of water, get rid of the fibre and spindly

particles that may get deposited in the pump’s cassing.

In the event of excessive deposits in the pump cassing,
dismantle the inlet filter by unscrewing the star screw.
Wash the pump casing and fit the inlet filter back on.

• E

very 3 months remove the mud from the bottom and

walls of the well.

• Eliminate the deposits from the floating switch, washing

it with fresh water.

Protect the pump from frost.

CAUTION!

“DRAINAGE”
Special instructions: It is not suitable for pumping:
sewage, sandy water.
The pump must never run dry.
The manufacturer’s warranty is null and void in
the event of damage to the pump caused by it
running dry.

“VORTEX”
The pump must never run dry.
The manufacturer’s warranty is null and void in
the event of damage to the pump caused by it
running dry.

CAUSES

The motor will not work

The motor works, the pump will not convey

Insufficient flow rate

Repeated switching off with disconnection of the protection switch

TROUBLE

No mains voltage, the floating swittch will not connect
Defective protection device
Motor protection disconnected, pump straining/blocked
Dry operation protection disconnected, the water level has fallen too much
Defective pump

Clogged suction opening
Check valve blocked or delivery pipe bent
Delivery pipe clogged

F

oreign bodies in the pump, pump impeller blocked

The pump runs dry

If it is not possibile to eliminate the trouble, please call our service department.

To avoid damage during transport, please ship in the ORIGINAL PACKING.

Troubleshooting Table

19

ENGLISH

 (Original instructions)

 

SUBMERSIBLE PUMP

Note:pollution of liquid could occur due to leakage of lubrican

Summary of Contents for DOLMAR EP1500-DS

Page 1: ...POMPASI POMPY ZATAPIALNE DO WODY BRUDNEJ POMPE SUBMERSIBILE PENTRU APE MURDARE MER L SZIVATTY PISZKOS V ZHEZ PONORN VODN ERPADLO NA PINAV VODU PONORN VODN ERPADLA NA PINAVOU VODU PODVODNA PUMPA ZA PR...

Page 2: ......

Page 3: ...raised position with respect to the bottom of 1 Safety measures Carefully read the operating instructions before assembling and starting The appliance must not be used by persons who are not thoroughl...

Page 4: ...during transport please ship in the ORIGINAL PACKING Troubleshooting Table 19 the well so that the muddy bottom is not sucked up with the water Never handle or hang the pump by gripping the power supp...

Page 5: ...ion class Kl B B B B Motor protection IP X8 X8 X8 X8 Capacitor F 6 16 8 16 Maximum head H max m 5 10 7 10 Maximum capacity Q max l min 140 240 180 250 Liquid temperature H20 max C 35 35 35 35 Submersi...

Page 6: ...ions relating to the treatment recovery and recycling of the said products In accordance with the regulations applied in the member States private users resident in the EU can take used electric andel...

Page 7: ...ht van de pomp moet een afmeting hebben van 1 Veiligheidsmaatregelen Lees de gebruiksaanwijzing aandachtig alvorens de pomp te installeren en in gebruik te nemen Het apparaat mag niet gebruikt worden...

Page 8: ...Verzend de pomp in de ORIGINELE VERPAKKING om transportschade te voorkomen 25 Tabel minstens 40x40x50 cm zodat de vlotterschakelaar vrij kan bewegen Ook kunnen geprefabriceerde ronde be tonnen schach...

Page 9: ...oom A 1 8 4 8 2 5 4 8 Isolatieklasse motor Kl B B B B Beveiliging motor IP X8 X8 X8 X8 Condensator F 6 16 8 16 Maximum kop H max m 5 10 7 10 Maximum capaciteit Q max l min 140 240 180 250 Vloeistof te...

Page 10: ...gssenter b r du kontakte forhandleren der du kj pte produktet Loven straffer den som ikke tar h nd om avfall p korrekt vis eller etterlater elektriske og elektroniske apparater i milj et 2002 96 FIN I...

Page 11: ...COD 00000 REV 0 11 2012...

Reviews: