Summary of Contents for DCL286FZB

Page 1: ...IEBSANLEITUNG 29 IT Aspiratore a batteria ISTRUZIONI PER L USO 40 NL Accustofzuiger GEBRUIKSAANWIJZING 50 ES Aspiradora Inalámbrica MANUAL DE INSTRUCCIONES 60 PT Aspirador de pó a bateria MANUAL DE INSTRUÇÕES 70 DA Akku støvsuger BRUGSANVISNING 80 EL Φορητή σκούπα ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ 89 TR Akülü Süpürge KULLANMA KILAVUZU 99 ...

Page 2: ...2 Fig 1 1 2 3 Fig 2 1 2 Fig 3 1 2 Fig 4 1 2 3 Fig 5 1 2 3 4 5 6 7 8 9 Fig 6 ...

Page 3: ...3 1 2 3 4 Fig 7 1 2 3 4 Fig 8 Fig 9 1 Fig 10 1 2 3 Fig 11 1 2 Fig 12 1 2 Fig 13 1 2 3 Fig 14 ...

Page 4: ...4 Fig 15 1 Fig 16 1 2 3 4 Fig 17 Fig 18 1 2 3 Fig 19 Fig 20 Fig 21 1 Fig 22 ...

Page 5: ...5 1 2 3 4 Fig 23 Fig 24 3 1 2 Fig 25 1 2 Fig 26 Fig 27 Fig 28 1 2 Fig 29 ...

Page 6: ...6 1 2 Fig 30 1 2 Fig 31 Fig 32 Fig 33 1 2 Fig 34 1 2 Fig 35 1 2 Fig 36 1 2 Fig 37 ...

Page 7: ...7 Fig 38 Fig 39 1 3 2 Fig 40 1 2 Fig 41 3 2 1 Fig 42 1 Fig 43 ...

Page 8: ...8 1 2 3 4 5 Fig 44 Fig 45 Fig 46 1 4 5 1 3 2 Fig 47 1 2 3 4 Fig 48 1 2 3 4 Fig 49 ...

Page 9: ...9 1 2 3 4 Fig 50 1 2 Fig 51 1 2 4 3 Fig 52 ...

Page 10: ...ppropriate details of precautions during user maintenance SPECIFICATIONS Model DCL286F Capacity 250 mL 400 mL country specific Continuous use with battery BL1830B 1 Quiet mode Approx 38 min 2 Normal speed mode Approx 21 min 3 High speed mode Approx 15 min 4 Max speed mode Approx 8 min Overall length with pipe nozzle and battery BL1830B 1 106 mm Rated voltage D C 18 V Net weight 1 6 2 0 kg Due to o...

Page 11: ...cleaning on stairs 10 Do not use to pick up flammable or combusti ble liquids such as gasoline or use in areas where they may be present 11 Use only the charger supplied by the manufac turer to recharge 12 Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes 13 Do not use without dust bag and or filters in place 14 Do not charge the battery outdoors 15 Recharg...

Page 12: ... 7 Do not incinerate the battery cartridge even if it is severely damaged or is completely worn out The battery cartridge can explode in a fire 8 Do not nail cut crush throw drop the battery cartridge or hit against a hard object to the battery cartridge Such conduct may result in a fire excessive heat or explosion 9 Do not use a damaged battery 10 The contained lithium ion batteries are subject t...

Page 13: ...ntil the red indicator cannot be seen If not it may accidentally fall out of the tool causing injury to you or someone around you CAUTION Do not install the battery cartridge forcibly If the cartridge does not slide in easily it is not being inserted correctly Tool battery protection system The tool is equipped with tool battery protection system This system automatically cuts off power to the mot...

Page 14: ... button 2 ON OFF button 3 Lamp PARTS DESCRIPTION Fig 6 1 250 mL dust case Optional accessory 2 400 mL dust case Optional accessory 3 Mesh filter 4 Cyclone body 5 High performance filter Filter frame in gray color Optional accessory 6 HEPA filter Filter frame in white color Optional accessory 7 Sponge sheet 8 Cleaner body 9 Hand strap Country specific ASSEMBLY CAUTION Always be sure that the tool i...

Page 15: ...er 2 Sash nozzle CAUTION Be careful not to trap finger s between the sash nozzle and the nozzle holder Trapping finger s may cause injury Sash nozzle Extension wand Straight pipe In tight quarters where the cleaner itself cannot squeeze in or in high places hard to reach use this arrangement Fig 14 1 Sash nozzle 2 Extension wand Straight pipe 3 Cleaner body Cleaning without nozzle With 250 mL dust...

Page 16: ...2 1 Cyclone unit 2 With the suction inlet pointing downwards turn the cyclone unit as shown in the figure aligning the pointer on the cyclone unit with that on the cleaner body to disengage the lock Then detach the cyclone unit from the cleaner body slowly and straightly Fig 23 1 Cyclone unit 2 Suction inlet 3 Pointers 4 Filter NOTE Dust may fly out when the cyclone unit is disassembled It is reco...

Page 17: ...detach it from the cyclone body Fig 43 1 Mesh filter 3 Disassemble the mesh filter into three compo nents prefilter tubular sponge filter and mesh pipe i Squeeze the guide stoppers on top of the mesh pipe together ii Pass the guide stoppers down through the guide hole on top of the prefilter iii Pull the prefilter along the tubular sponge filter and mesh pipe iv Remove the tubular sponge filter fr...

Page 18: ...battery cartridge Noise and vibration Are filters clogged Dust down or wash high performance filter HEPA filter sponge sheet mesh filter Anything to block openings or holes Clean any dust and objects out of nozzles pipes and air openings Is suction inlet of nozzle or pipe closed Uncover and open suction inlet of nozzle and pipe CAUTION Do not attempt to repair the cleaner by yourself OPTIONAL ACCE...

Reviews: