background image

Lighting up the lamp 

 

CAUTION: 

• 

Do not look in the light or see the source of light 
directly. 

1

 

 

013570 

Pull the switch trigger to light up the lamp. The lamp 
keeps on lighting while the switch trigger is being pulled. 
The lamp goes out approximately 10 seconds after the 
switch trigger is released. 

 

NOTE: 

• 

Use a dry cloth to wipe the dirt off the lens of lamp. 
Be careful not to scratch the lens of lamp, or it 
may lower the illumination. 

• 

When the tool is overheated, the lamp flickers. 
Cool down the tool fully before operating again. 

Drip preventive function 

The motor keeps running for a short time even after the 
trigger is released. It releases the pressure of the 
caulking material and prevents dripping. 

ASSEMBLY 

 

CAUTION: 

• 

Always be sure that the tool is switched off and the 
battery cartridge is removed before carrying out 
any work on the tool. 

• 

Always place the tool on the ground or workbench 
when carrying out any assembling work. The tool 
without being held tight may loose balance and 
cause injury. 

Installing holder joint 

   

013610 

Attach the holder joint firmly along the tool, set the plate, 
and fix them with screws tightly. 

To remove the holder joint, follow above procedure in 
reverse. 

 

NOTE: 

• 

There are two types of holders (optional 
accessory), short holder (300ml) and long holder 
(600ml).    Use appropriate holder joint accordingly. 

Installing rod and piston 

A

B

C

   

013612 

A

B

C

   

013611 

Insert the rod into the slit of the tool. 
Attach the piston and tighten it with a screw. 
To remove the rod and piston, follow the installation 
procedure in reverse. 

NOTICE: 

• 

The teeth on the rod must point down. 

• 

There are three types of pistons. Piston A for 
cartridges. Piston B for film type packs. Piston C 
for direct filling. 

• 

Choose appropriate piston in accordance with the 
type of caulking material container. Improper 
piston may cause leakage or tool breakage. 

• 

There are two types of rods. The short rod for the 
short holder (300ml), and the long rod for long 
holder (600ml). Use appropriate rod in accordance 
with holder type. 

• 

Always keep the rod and piston clean. Adhering 
caulk may damage the tool. 

 
 
 
 

1. Lamp 

Summary of Contents for DCG180RMB

Page 1: ...1 ENGLISH Original instructions INSTRUCTION MANUAL IMPORTANT Read Before Using Cordless Caulking Gun BCG140 BCG180 013564 ...

Page 2: ...rdance with national laws electric equipment and battery pack that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility ENE086 1 Intended use This tool is intended for applying caulking material to surface ENG905 1 Noise The typical A weighted noise level determined according to EN60745 Sound pressure level LpA 70 dB A or ...

Page 3: ...unded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is earthed or grounded 6 Do not expose power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock 7 Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edge...

Page 4: ...zardous situation Battery tool use and care 24 Recharge only with the charger specified by the manufacturer A charger that is suitable for one type of battery pack may create a risk of fire when used with another battery pack 25 Use power tools only with specifically designated battery packs Use of any other battery packs may create a risk of injury and fire 26 When battery pack is not in use keep...

Page 5: ...ery cartridge once in every six months if you do not use it for a long period of time FUNCTIONAL DESCRIPTION CAUTION Always be sure that the tool is switched off and the battery cartridge is removed before adjusting or checking function on the tool Installing or removing battery cartridge 1 2 3 013558 CAUTION Always switch off the tool before installing or removing of the battery cartridge Hold th...

Page 6: ...ulking material the rod may get clogged when operating with low speed In that case set the speed adjusting dial higher Overload warning lamp 1 013557 The warning lamp flickers in red when the tool is overloaded If the load reaches some point the lamp keeps lighting in red and the tool stops To restart the tool release the trigger and pull the trigger again NOTE Check what causes the overload when ...

Page 7: ...ool without being held tight may loose balance and cause injury Installing holder joint 013610 Attach the holder joint firmly along the tool set the plate and fix them with screws tightly To remove the holder joint follow above procedure in reverse NOTE There are two types of holders optional accessory short holder 300ml and long holder 600ml Use appropriate holder joint accordingly Installing rod...

Page 8: ...ml 1 013566 Pull the rod handle backwards slowly until it stops 013567 Insert the cartridge into the holder as illustrated Push the rod gently until the piston touches the bottom of the cartridge To remove the cartridge pull the rod backwards until it stops then lift out the cartridge Installing the cartridge into the long holder 600ml 1 2 013572 Remove the holder cap from the holder Pull the rod ...

Page 9: ...l breakage OPERATION CAUTION Do not touch the rod during operation Otherwise your finger may be pinched between the rod and the housing of the tool Always wear goggles during operation NOTICE Do not cover vents or it may cause overheating and damage to the tool If you can not pull out the rod turn the speed adjusting dial to 1 and pull the switch trigger for a moment and try to pull the rod out af...

Page 10: ...ion and replacement any other maintenance or adjustment should be performed by Makita Authorized Service Centers always using Makita replacement parts OPTIONAL ACCESSORIES CAUTION These accessories or attachments are recommended for use with your Makita tool specified in this manual The use of any other accessories or attachments might present a risk of injury to persons Only use accessory or atta...

Page 11: ...11 ...

Page 12: ...12 Makita Corporation Anjo Aichi Japan www makita com 885189 229 ...