background image

P 6 / 8

[2] Motor Housing

High Voltage Countries and Areas
where Noise Suppression is Required by Regulation

Fig. 15

Fig. 16

W

iring diagram

Put Earth terminal in place as illustrated in Fig. 15

[3] Handle portion of motor Housing

Noise suppressor

Motor Housing

Motor housing viewed from

Polyolefin tube

Lead Wire (clear)

Noise 
Suppressor

Earth terminal

Field

Terminal block

Choke Coil

Warning lamp

Lead wire holder

Earth terminal

Motor Housing

Rib

Switch

Be careful not to route the lead wires (black)
of Noise suppressor over the ribs.

Fix the following two lead
wires with the lead wire
holder, and be sure that
they are are tight in this
portion;
* Lead Wire (white) 
   from Support complete
* Connecting lead wire
   (orange) from Brush
   holder

Fix lead wire (clear) of Noise suppressor
with the lead wire holders.

Summary of Contents for 6305

Page 1: ...Auger bits 9 12 15 Grip 36 assembly Model 6305 features Rear handle with soft rubber grip ergonomically designed for comfortable operation Warning lamp that indicates trouble with the cord the switch...

Page 2: ...Ratchet Head 12 7 Modular use with No 1R223 Note When removing broken Drill chuck for instance the jaws do not function to tighten the bit use Wrench 43 No 781024 2 instead of No 1R223 and 1R224 Fig...

Page 3: ...housing by pressing from the threaded end Fig 7 Fig 6 Fig 7 Fig 9 Fig 8 Woodruff Key 4 Sleeve 15 Ball Bearing 607LLB Helical Gear 34 Gear Complete 12 41 Spindle Spindle Ball Bearing 6202LLB ASSEMBLING...

Page 4: ...everse of the disassembling steps 6 Remove Ball bearing 608LLB from the commutator end of Armature as described below The space between the ball bearing and Insulation washer is so tight that claws of...

Page 5: ...Orange Clear Heat shrink tube Fig 13 Fig 14 Circuit diagram Wiring diagram Heat shrink tube Insert Heat shrink tube polyolefin tube through the lead wire clear and connect Earth terminal with the lea...

Page 6: ...e Lead Wire clear Noise Suppressor Earth terminal Field Terminal block Choke Coil Warning lamp Lead wire holder Earth terminal Motor Housing Rib Switch Be careful not to route the lead wires black of...

Page 7: ...iagram As illustrated in Fig 18 route the two lead wires white from Support complete through Line filter before connecting to Switch and Terminal block Line filter Noise suppressor is not used for som...

Page 8: ...e suppressor if used Switch Line filter if used Rib Be careful not to route the lead wires black of Noise suppressor over the ribs Fix lead wire clear of Noise suppressor with the lead wire holders Le...

Reviews: