background image

R

epair

Removing Base
Remove three countersunk-head screws (M5x8) that fix Angular plate complete and two countersunk head 
screws (M4x8) that fixes Depth guide complete, then remove base.
Removing spur gear 53
 1) Remove two countersunk-head screws and take off Bearing box from the Blade case.  
 2) Remove Bearing retainer (left-handed screw), 
 3) Place Bearing box at Arbor press stand
 4) Place rod on the rear of spindle and press it by arbor, and Spindle can be removed.

(1)

(2)

Arbor press stand

Rod ø5.5mm or under

40mm

40mm

Bearing retainer

Arbor prees stand

Reviews: