R
epair
Removing Base
Remove three countersunk-head screws (M5x8) that fix Angular plate complete and two countersunk head
screws (M4x8) that fixes Depth guide complete, then remove base.
Removing spur gear 53
1) Remove two countersunk-head screws and take off Bearing box from the Blade case.
2) Remove Bearing retainer (left-handed screw),
3) Place Bearing box at Arbor press stand
4) Place rod on the rear of spindle and press it by arbor, and Spindle can be removed.
(1)
(2)
Arbor press stand
Rod ø5.5mm or under
40mm
40mm
Bearing retainer
Arbor prees stand