REFUELING 

 

WARNING

 

 

FAILURE TO USE FUEL AS RECOMMENDED IN THIS 
MANUAL WILL VOID WARRANTY 

 

 

DO NOT

 use unapproved gasoline such as ethanol-based fuel. 

 

DO NOT

 mix oil with gasoline. 

 

DO NOT

 modify engine to run on alternate fuels. 

 

WARNING

 

Fuel and fuel vapour are extremely flammable 
and explosive. Fire or explosion from misuse 
of fuel can cause severe burns and even death.

 

 

  

FIRE 

HAZARD 

 

 

WARNING

 

Always ensure that fuel tanks are filled outdoors.

 

1.  Turn generator 

OFF

 and let it cool for at least two minutes before removing 

fuel cap. 

2.  Loosen fuel cap slowly to release pressure. 

3.  Slowly add unleaded gasoline to fuel tank. 

DO NOT

 fill fuel above baffle to 

allow for appropriate space fuel expansion. 

4.  Wait for spilled fuel to evaporate before starting the engine. 

 

WARNING

 

Keep  fuel  away  from  sparks,  open  flames,  pilot  lights, 
heat and other ignition sources.  
 
 
 
DO  NOT  light a  cigarette  or  smoke  near  open  fuel  tank 
or container.

 

Summary of Contents for GEN-9P-US-240

Page 1: ...Makinex 9kW Generator GEN 9P US 240 3 PHASE GENERATOR OPERATOR S MANUAL REV0919...

Page 2: ...OVERALL MACHINE DIMENSIONS 10 ALTERNATOR SPECIFICATIONS 10 OPERATION 10 OPERATING GENERATOR 13 CONNECTING ELECTRICAL DEVICES 13 SHUTTING DOWN THE GENERATOR 13 MAINTENANCE 14 GENERAL RECOMMENDATIONS 1...

Page 3: ...MAKINEX No part of this publication may be reproduced in any form or by any means electronic or mechanical including photocopying without express written permission from MAKINEX Any type of reproduct...

Page 4: ...hat should be paid careful attention CAUTION CAUTION indicates a potential hazardous situation which if not avoided may result in minor or moderate injury WARNING WARNING indicates a potentially hazar...

Page 5: ...struct operators in care and use of the machine before use GENERAL SAFETY PRECAUTIONS ALWAYS use in a well ventilated area ALWAYS ensure the applied load does not exceed the generators rating Overload...

Page 6: ...evel specified NEVER smoke whilst refuelling and avoid smoking or using a naked flame near the generator NEVER start the engine if there is a fuel spill Any spillage must be wiped clean and the genera...

Page 7: ...s During operation touch only the control surfaces of generator Keep children away from the generator at all times They may not be able to recognise the hazards of this product WARNING POSITIONING THE...

Page 8: ...rce Portable generators are inherently more dangerous than fixed generators as they are not permanently earthed Therefore appropriate measures must be taken to properly set up the earthing of the gene...

Page 9: ...and a 3 prong plug on opposite ends to maintain earth protection from the generator to the appliance We strongly recommend that all applicable federal state and local regulations relating to groundin...

Page 10: ...GEN 9P US 240 User Manual Page 8 of 22 SAFETY DECAL...

Page 11: ...tion 240V WEIGHT 100 kg 220 lbs NOISE LEVEL 7M NO LOAD 72dB 50 LOAD 76dB 100 LOAD 78dB RATED POWER FACTOR 0 8 ENGINE TYPE AIR COOLED 4 STROKE OHV MODEL HONDA GX390 STARTING SYSTEM PULL START DISPLACEM...

Page 12: ...GEN 9P US 240 USER MANUAL Page 10 of 22 OVERALL MACHINE DIMENSIONS ALTERNATOR SPECIFICATIONS Figures vary by model 240V model shown...

Page 13: ...oil using oil funnel optional slowly pour contents into oil fill opening 4 Replace oil fill cap and tighten NOTE Refer to GX390 Manual for more in depth instructions NOTE New machines will be pre oile...

Page 14: ...e severe burns and even death FIRE HAZARD WARNING Always ensure that fuel tanks are filled outdoors 1 Turn generator OFF and let it cool for at least two minutes before removing fuel cap 2 Loosen fuel...

Page 15: ...nce and then pull up sharply to start the generator 6 Once the engine has warmed up set the choke lever to the OFF position CONNECTING ELECTRICAL DEVICES The generator can supply 120V AC through 2x20A...

Page 16: ...including proper storage NOTE An hour meter is installed on the machine to help with tracking operation hours Refer to Honda GX390 user manual provided at sale for engine related maintenance Should y...

Page 17: ...ARD RUST PREVENTION IN CYLINDERS 1 Remove spark plugs and pour approx 15ml 1 2oz of clean engine oil into the cylinder 2 Install spark plug and briefly turn the key starter for 1 2 seconds to distribu...

Page 18: ...uthorised MAKINEX dealer for servicing Only authorised MAKINEX dealers have access to all the special tools technical information parts and training required to maintain your MAKINEX product in peak o...

Page 19: ...n due to build up is not covered by this warranty OTHER EXCLUSIONS This warranty excludes Cosmetic defects such as paint decals etc Wear items such as filter elements etc Accessory parts such as start...

Page 20: ...or domestic territories only e g Australian units will be delivered within Australian territory USA units will be delivered within USA territory and European units will be delivered within its designa...

Page 21: ...w makinex com au SERVICE SPARE PARTS WARRANTY EMAIL service makinex com au USA SALES TEL 1 855 625 4639 WEB www makinex com SERVICE SPARE PARTS WARRANTY EMAIL service makinex com UK WEB www makinex co...

Page 22: ...GEN 9P US 240 User Manual Page 20 of 22 APPENDIX A RISK ASSESSMENT...

Page 23: ...GEN 9P US 240 USER MANUAL Page 21 of 22 APPENDIX B WIRING DIAGRAMS GEN 9P US 208V 240V WIRING DIAGRAM...

Page 24: ...GEN 9P US 240 USER MANUAL Page 22 of 22...

Reviews: