Page
39
of
56
Water in oil
Guide piston gasket worn
Replace the gaskets (1)
High humidity percentage in air
Change the oil twice as often
Worn gaskets
Replace the gaskets (1)
Oil leak from pump
Worn gaskets
Replace the gaskets (1)
Worn pistons
Replace the pistons (1)
Loose drain plug
Tighten drain plug
pump overfilled
Check for correct amount
incorrect oil use
Drain and refill with correct type and
amount of oil
Oil seals worn
Replace seals (1)
Water leaking at pump
loose connections
Tighten connections
Piston packings worn
Check and replace (1)
Worn or broken O-rings
replace O-rings
Pump head or tubes damaged
from freezing
Check and replace (1)
Engine shuts down when
running
Out of fuel
Fill fuel tank
Low engine oil
Add oil
Engine will not start
Out of fuel
Fill fuel tank
Low engine oil
Add oil
wrong fuel
Drain and refill recommended fuel
Rocker switch set to off
Set to on
Fuel valve is in off position
Set to on
Spark plug wire not connected to
spark plug
Check and make sure its wired
Faulty spark plug
Check and replace
Water in fuel
Drain tank and carburetor and refill
Flooded
Wait 5 minutes and re-crank engine
Engine too hot
Allow engine to cool
Choke in wrong position
Change choke position
too much pressure build up
Release pressure
(1) operations which must be carried out at an authorised service centre
Summary of Contents for DPW-4000
Page 10: ...Page 10 of 56 SAFETY DECALS NOTE Model DPW 4000...
Page 13: ...Page 13 of 56 OVERALL MACHINE DIMENSIONS NOTE Model DPW 4000...
Page 16: ...Page 16 of 56 CONTROLS AND FEATURES NOTE Model DPW 4000...
Page 52: ...Page 50 of 56 APPENDIX E PUMP PARTS BREAK DOWN Model AR XW15 30N MODEL DPW 4000...
Page 53: ...Page 51 of 56 Model 2 SXW15 35...
Page 54: ...Page 52 of 56 Model 3 RKV3 5G40HD F24...
Page 55: ...Page 53 of 56 APPENDIX F ROTARY CLEANER EXPLODED PARTS...
Page 56: ...Page 54 of 56...
Page 57: ...Type text APPENDIX G RISK ASSESSMENT...
Page 58: ...Page 56 of 56...