background image

Product Parameters

Model: N10
Input voltage: 3.8V-30V
Input current: 0-3.000A
Capacity measurement range: 0-99999Ah
Energy measurement range: 0-99999Wh
Load impedance measurement range: 1.5
Ω-9999.9Ω
Temperature measurement range: 
-20°C~80°C/4°F~176°F
Screen brightness setting: 0-5 a total of 6 levels
Voltage curve range: 3.8V-30V
Product size: 73mm*35mm*10mm
Display screen: 1.44-inch color LCD screen

Product weight: 20.5g (net weight)
Voltage measurement resolution: 0.01V
Current measurement resolution: 0.001A
Voltage measurement accuracy: ±1%
Current measurement accuracy: ±1%
Time measurement range: 0-99 hos 59 mics 59 seds

Temperature measurement error: ±2°C/ ±3.6°F

Delay off screen time: 0-9 minutes
Current curve range: 0.00A-3.00A
Fast charge recognition mode: QC2.0 QC3.0
Refresh rate: 50Hz

Summary of Contents for N10

Page 1: ...functional Tester Model N10 Dear user In order to let you know all the functions of this product faster get a better user experience and avoid misoperation please read this manual carefully before use...

Page 2: ...evels Voltage curve range 3 8V 30V Product size 73mm 35mm 10mm Display screen 1 44 inch color LCD screen Product weight 20 5g net weight Voltage measurement resolution 0 01V Current measurement resolu...

Page 3: ...1 44 inch color LCD display USB female interface USB male interface Multi function buttons Multi function buttons Type c interface support PD fast charging Type c interface support PD fast charging M...

Page 4: ...next time When the data group number is selected long press the Help button to clear the accumulated capacity value and accumulated energy value in this group of data groups Short press the Next butt...

Page 5: ...to the main interface 4 line resistance measurement interface 2 1 2 3 4 1 3 1 D DP data positive signal 2 D DM data negative signal 3 Mode display QC2 0 QC3 0 mode Short press the Next button to swit...

Page 6: ...e load current recommended to connect to a xed voltage and current long press the Next button to record the data and the indicator icon on the right stops ashing Step 2 Unplug the tester connect the t...

Page 7: ...interface Main interface 5 voltage curve interface This interface is the current measurement waveform diagram which automatically changes the range within the measurement range of 0 00A 3 00A and disp...

Page 8: ...always on Long press the Next button to enter the screen brightness setting select the corresponding number and display it inversely short press to change the size of the number the larger the number...

Page 9: ...detection current ow direction indication and alarm reminder functions Temperature alarm exceeds 45 the temperature display will ash voltage alarm less than 3 8V or greater than 30V the voltage displa...

Page 10: ......