![Make Noise 0-CTRL Manual Download Page 8](http://html1.mh-extra.com/html/make-noise/0-ctrl/0-ctrl_manual_3820384008.webp)
8
Panel controls, Inputs and Outputs
1.
Clock Input
. Advances sequence upon rising edge of clock, pulse or trigger signal of at least 2.0V
2.
Clock Output
. Output containing gates associated with Internal and/or External Clocks. 0V or 8V.
3.
Dynamic Reset
Input
. Resets sequence to last touched Step upon rising edge of clock, pulse or trigger signal of at least
2.0V
4.
Stop Input
. Stops clock (internal and external) from advancing sequence for as long as input is >2.0V.
5.
Direction Input
. Changes/toggles sequence direction upon rising edge of clock, pulse or trigger signal of at least 2.0V.
6.
Pitch Channel CV Output
. Outputs CV at value of Pitch Channel knob for currently selected Step. 0-5V.
7.
Strength Channel CV Output
. Outputs CV at value of Strength Channel knob for currently selected Step. 0-5V.
8.
Time Channel CV Output
. Outputs CV at value of Time Channel knob for currently selected Step. 0-5V.
9.
Pressure CV Output
. Outputs CV according to amount of pressure applied to Step Touchplate(s). 0-5V.
10.
Touch Gate Output
. Outputs Gate signal when one or more Step Touchplate is being touched. 0V or 8V.
11.
Dynamic Gate Output
. Outputs Dynamic Gate Signal based on Strength and Time of current Step. 0-8V.
12.
Dynamic Envelope Output
. Outputs Dynamic Envelope based on Strength and Time of current Step. 0-8V.
13.
Strength CV Input attenuator
. Sets depth of Strength modulation from Strength Channel or signal at Strength CV Input.
14.
Speed Panel Control
. Sets Speed of Internal Clock and length of Dynamic Envelopes and Gates.
15.
Strength CV Input
. Modulates Strength of Dynamic Envelope and Gate outputs. Normalled to Strength Channel CV
Output.
16.
Time CV Input Attenuator
. Sets depth of Time modulation from Time Channel or signal at Time CV Input.
17.
Time CV Input
. Modulates Clock Time. Normalled to Time Channel CV Output.
18.
Step Gate Outputs
. Gate outputs that go high when respective Step is active. 0V or 8V.
19.
Pitch Channel Knobs
. Set Pitch Channel CV Output for the eight steps.
20.
Strength Channel Knobs
. Set Strength Channel CV Output for the eight steps.
21.
Time Channel Knobs
. Set Time Channel CV Output for the eight steps.
22.
Step Touchplates
. Clocks Sequence to respective Step (if Interrupt ON) and generate Pressure CV and Touch Gates.
23.
Clock Touchplate
. Turns Internal Clock On and Off.
24.
Direction Touchplate
. Changes/Toggles Direction of Sequence.
25.
Interrupt Touchplate
. Determines whether Step Touchplates will Interrupt the Sequence when touched.
Summary of Contents for 0-CTRL
Page 1: ...0 CTRL...