background image

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.

When Installing the Unit

     Never   plug  in   nor remove the power  supply   plug
    with  wet  hands,  as  doing  so  may cause electric
    shock.

     When unplugging   the  power   supply cord, be sure
     to grasp the   power  supply   plug; never  pull on the
    cord  itself.  Operating   the  unit   with  a  damaged
    power  supply  cord  may  cause  a  fire  or  electric 
    shock.

     When moving the unit, be sure  to remove its power 
     supply cord   from the  wall   outlet.  Moving   the unit
     with the   power  cord   connected  to   the outlet may
     cause damage to the power cord,  resulting in fire or 
     electric shock. When   removing the power cord,  be
     sure to hold its plug to  pull.

  Do not block the ventilation slots in the unit's cover.
  Doing so may cause heat to build up inside the unit 
  and result in fire.

  Avoid installing the unit in humid or dusty locations,
  in locations exposed to the direct sunlight, near the 
  heaters, or in locations generating   sooty smoke or
  steam  as  doing  otherwise  may  result  in  fire  or 
  electric shock.

When the Unit is in Use

     Do not place heavy objects on the unit  as  this   may
    cause   it  to  fall  or  break   which   may   result   in 
    personal   injury    and/or    property    damage.   In
    addition,  the  object  itself  may  fall  off  and  cause
    injury  and/or  damage.

    Make  sure   that   the  volume   control   is   set   to
    minimum  position   before  power  is  switched   on.
     Loud noise produced at high volume when power  is 
    switched  on  can  impair  hearing.

     Do not operate   the  unit   for an  extended   period of 
     time with   the sound distorting. This  is   an indication
     of   a  malfunction,   which  in   turn  can cause heat to
     generate and result in a fire.

     Contact your MAJORCOM dealer as   to the  cleaning. 
    If  dust is  allowed  to accumulate  in  the  unit  over  a
     long period of   time, a  fire   or  damage   to  the   unit  
    may result.

  If dust accumulates on the power supply  plug or in
  the  wall  AC  outlet,  a  fire  may  result.  Clean  it 
  periodically. In addition, insert the plug in the wall 
  outlet securely.

  Switch off   the  power, and unplug the power   supply
  plug   from the  AC outlet   for  safety   purposes when 
  cleaning   or  leaving the unit unused for   10  days or 
  more. Doing otherwise   may cause a fire  or   electric 
  shock.

SAFETY PRECAUTIONS

2

Summary of Contents for RM-4012

Page 1: ...unit We also recommend that you keep this manual handyfor future reference OPERATION MANUAL RM 4012 MICROPHONE WITH ZONE CONTROL PUBLIC ADDRESS SYSTEM ZONE 1 ZONE 2 ZONE 3 ZONE 4 ALL CALL POWER CHIME...

Page 2: ...TABLE OF CONTENTS 1 SAFETY PRECAUTIONS 1 2 FEATURES 3 3 NOMENCLATURE AND FUNCTIONS 3 1 Front Panel 4 3 2 Rear Panel 4 4 OPERATION 5 5 APPLICATIONS 8 6 BLOCK DIAGRAM 9 7 SPECIFICATIONS 10...

Page 3: ...ire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric sh...

Page 4: ...ooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in per...

Page 5: ...nes paging by manual capacity It has online function and an online interface for LINK IN LINK OUT Built in independent switching power supply Built in chime 2 4 tone selector MIC Chime master volume c...

Page 6: ...volume control adjustment 12 MIC volume control adjustment 13 Master volume control adjustment 14 Chime times selection switch 4 3 NOMENCLATURE AND FUNCTIONS 3 1 FRONT PANEL 2 3 5 4 6 7 8 9 10 11 12 1...

Page 7: ...uts off and the indicator is off Note 1 MIC MIC MIC MIC 2 MIC When the is connected make sure there is power supply to the and the could be turned on to work normally or the could not be paged Make su...

Page 8: ...2T it means two audio signals are selected when turned to 4T it means four audio signals are selected Note 1 Please be more careful when turning the chime tone selector to avoid any damage of the sel...

Page 9: ...4 are 50MS 100MS 150MS and 200MS but the setting cannot be the same Once the conversation is over if the local sub unit has the priority it will be into conversa tion state and the MIC light will tur...

Page 10: ...PANEL CONNECTIONS MICROPHONE WITH ZONE CONTROL 4 ZONE PA MIXER AMPLIFIER ON OFF CHIME VOL MASTER VOL MIC VOL CHIME 2 TONE 4 TONE LINK 24V 2A POWER ON OFF CHIME VOL MASTER VOL MIC VOL CHIME 2 TONE 4 T...

Page 11: ...9 6 BLOCK DIAGRAM...

Page 12: ...microphone THD POWER CONSUMPTION COMMUNICATION DISTANCE FREQUENCY RESPONSE RM 4012 10W 1KM COMMUNICATION MODE 4 ZONE 1V 600 Level control 10 7 SPECIFICATIONS 1 POWER SUPPLY DIMENSION DC 24V 197x115x43...

Page 13: ...Version V0 1 PUBLIC ADDRESS SYSTEM...