Majorcom: PX-4120 Operation Manual Download Page 4

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.

When Installing the Unit

     Never   plug  in   nor remove the power  supply   plug
    with  wet  hands,  as  doing  so  may cause electric
    shock.

     When unplugging   the  power   supply cord, be sure
     to grasp the   power  supply   plug; never  pull on the
    cord  itself.  Operating   the  unit   with  a  damaged
    power  supply  cord  may  cause  a  fire  or  electric 
    shock.

     When moving the unit, be sure  to remove its power 
     supply cord   from the  wall   outlet.  Moving   the unit
     with the   power  cord   connected  to   the outlet may
     cause damage to the power cord,  resulting in fire or 
     electric shock. When   removing the power cord,  be
     sure to hold its plug to  pull.

  Do not block the ventilation slots in the unit's cover.
  Doing so may cause heat to build up inside the unit 
  and result in fire.

  Avoid installing the unit in humid or dusty locations,
  in locations exposed to the direct sunlight, near the 
  heaters, or in locations generating   sooty smoke or
  steam  as  doing  otherwise  may  result  in  fire  or 
  electric shock.

When the Unit is in Use

     Do not place heavy objects on the unit  as  this   may
    cause   it  to  fall  or  break   which   may   result   in 
    personal   injury    and/or    property    damage.   In
    addition,  the  object  itself  may  fall  off  and  cause
    injury  and/or  damage.

    Make  sure   that   the  volume   control   is   set   to
    minimum  position   before  power  is  switched   on.
     Loud noise produced at high volume when power  is 
    switched  on  can  impair  hearing.

     Do not operate   the  unit   for an  extended   period of 
     time with   the sound distorting. This  is   an indication
     of   a  malfunction,   which  in   turn  can cause heat to
     generate and result in a fire.

     Contact your MAJORCOM dealer as   to the  cleaning.
    If  dust is  allowed  to accumulate  in  the  unit  over  a 
     long period of   time, a  fire   or  damage   to  the   unit  
    may result.

  If dust accumulates on the power supply  plug or in
  the  wall  AC  outlet,  a  fire  may  result.  Clean  it 
  periodically. In addition, insert the plug in the wall 
  outlet securely.

  Switch off   the  power, and unplug the power   supply
  plug   from the  AC outlet   for  safety   purposes when 
  cleaning   or  leaving the unit unused for   10  days or 
  more. Doing otherwise   may cause a fire  or   electric 
  shock.

SAFETY PRECAUTIONS

4

Summary of Contents for PX-4120

Page 1: ...LEVEL LEVEL POWER PROT CH 5 CH 4 CH 3 CH 2 CH 1 BASS BASS BASS BASS BASS TREBLE TREBLE TREBLE TREBLE TREBLE 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 ZONE 4 ZONE 3 ZONE 2 ZONE 1 MON...

Page 2: ...ENCLATURE AND FUNCTIONS 3 1 Front Panel 6 3 2 Rear Panel 7 4 OPERATION 8 5 MUTE FUNCTION 8 6 TROUBLE SHOOTING 8 7 CONNECTIONS 7 1 Speaker Connections 9 7 2 XLR Connections 9 8 APPLICATIONS 10 9 BLOCK...

Page 3: ...fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is applied to the speaker terminals never touch these terminals to avoid electric s...

Page 4: ...ooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in per...

Page 5: ...n control 6 5 roads separate adjustable tone and volume control 7 The volume from all audio source in 1 4 zone can be adjusted 8 4 roads LINE output output is not controlled by monitor volume 9 Power...

Page 6: ...increase volume conversely reduce 12 CH1 volume control 13 MP3 player with USB SD card slot 3 1 FRONT PANEL 6 2 3 4 5 6 7 8 9 10 11 12 13 SD MEDIA POWER EQ MODE VOL NEXT PP SCAN VOL PREV 97 60 MONITOR...

Page 7: ...onnected to constant resistance 4 speaker 70V terminal can be connected to 70V constant voltage speaker 100V terminal can be connected to 100V constant voltage speaker 13 ZONE1 LINE signal output 14 R...

Page 8: ...nel short circuit terminals Normally MIC1 is with the highest priority 6 TROUBLE SHOOTING Fault phenomenon There is no sound output when the line connection is good The cause of the problem 1 No elect...

Page 9: ...7 CONNECTIONS 7 1 SPEAKER CONNECTIONS 70V 4 7 2 XLR CONNECTIONS 9 70V 100V COM 4 100V LINE 70V LINE 70V 100V COM 4 70V 100V COM 4 40 PX 4120 83 PX 4120...

Page 10: ...T LINE OUT BAL UNBAL BAL UNBAL BAL UNBAL BAL UNBAL G G G G 100V 100V 100V 100V OUTPUT OUTPUT OUTPUT OUTPUT 70V 70V 70V 70V 4 4 4 4 COM COM COM COM 220V 50 60Hz 800W T8AL 250V L L R R LINE PHANTOM PHAN...

Page 11: ...9 BLOCK DIAGRAM 11 ZONE ID 1 2 3 4 REMOTE MIC...

Page 12: ...GROSS WEIGHT 484X440X132 13 48Kg 11 68Kg SNR FREQUENCY MP3 RECORDING FORMAT 80 16KHz 0 3dB Support MP3 format max capacity of 32GB WAV INPUT SENSITIVITY AND IMPEDANCE CH1 2 3 2 5mV 600 175mV 10K bala...

Page 13: ...UNBAL BAL UNBAL BAL UNBAL BAL UNBAL G G G G 100V 100V 100V 100V OUTPUT OUTPUT OUTPUT OUTPUT 70V 70V 70V 70V 4 4 4 4 COM COM COM COM 220V 50 60Hz 800W T8AL 250V L L R R LINE PHANTOM PHANTOM PHANTOM LI...

Page 14: ...PUBLIC ADDRESS SYSTEM VersionV0 1...