background image

 

Indicates that this instrument can clamp on   

 

bare conductors when measuring a voltage   

 

corresponding to the applicable measurement   

 

category, which is marked next to this symbol. 

 

 

AC 

 

DC 

 

Ground (Earth) 
This instrument is subject to WEEE Directive   
(2002/96/EC). Please contact our dealer near   
you at disposal. 

 

 

Measurement Category 

 

 
CAT.II

 

Primary  electrical  circuits  of  equipment  connected 
to an AC electrical outlet by a power cord. 
 

 
CAT.III 

Primary  electrical  circuits  of  the  equipment 
connected  directly  to  the  distribution  panel,  and 
feeders from the distribution panel to outlets. 
 

CAT.IV 

The  circuit  from  the  service  drop  to  the  service 
entrance, and to the power meter and primary over 
current protection device(distribution panel). 
 

 

Current  measurement  section  of  this 
instrument  is  designed  for  CAT.III  600V 
and  Voltage  measurement  section  is  for 
CAT.III 300V / CAT.II 600V respectively. 
 
Test leads 7107A with the Cap is designed 
for CAT.IV 600V / CAT.III 1000V and without 
the Cap is for CAT.II 1000V.

 

 

DANGER 

 

● Never make measurement on a circuit in which   
  voltage over AC/DC600V exists. 
 
● Do not attempt to make measurement in the   
  presence of flammable gasses. Otherwise, the   
  use of the instrument may cause sparking, which   
  can lead to an explosion. 
 
● Never attempt to use the instrument if its surface   
  or your hand is wet. 
 
● Do not exceed the maximum allowable input of   
  any measuring range. 
 
● Never open the Battery cover during a   
  measurement. 
 
● To avoid electrical shock by touching the   
  equipment under test or its surroundings,   
  be sure to wear insulated protective gear. 

 

● Never measure current while the test leads are   
  inserted into the input terminals. 
 
● Barriers on the instrument body and the test leads   
  provide protection to keep your fingers and   
  hands from touching an object under test. 
  Keep your fingers and hands behind the barriers   
  during measurement. 

 

 

WARNING 

 

● Never attempt to make measurement if any   
  abnormal conditions, such as broken case and   
  exposed metal parts are found on the instrument   
    or test leads. 
 
● Verify proper operation on a known source before   
  use or taking action as a result of the indication   
  of the instrument.   
 
● 

Firmly attach the Caps to the test leads   

  when performing measurements at   
  CAT.III or higher test environment.

 

 

When MT750 and the test leads are   

  combined and used together, whichever   
  is lower category & voltage to earth   
  either of them belong to is applied. 

 
● Do not rotate the Function switch while the test   
  leads are being connected. 
 

● Do not install substitute parts or make any   
  modification  to  the  instrument.  For  repair  or 
  re-calibration, return the instrument to your local 
  distributor from where it was purchased. 

 

 

 

        CAUTION 

 

● Use of this instrument is limited to domestic,   
  commercial and light industry applications. 

 

If equipments generating strong electromagnetic   

  Interference or strong magnetic fields due to   
  large currents exist nearly, malfunctions of the   
  instrument may be caused. 
 
● Set the Function switch to an appropriate   
  position before starting measurement. 
 
● Firmly insert the test leads. 
 
● The LCD shows some readings at the ACV and   
  the DCV ranges even while the test leads are   
  open. And, it may show some digits instead of 0   
  when short-circuiting the test leads. However,   
 

these phenomena don’t affect measurement   

  results. 
 
● This instrument isn’t dust & water proofed. 
  Keep away from dust and water. 
 
● Be sure to power off the instrument after use.   
  When the instrument will not be in use for a long   
  period, place it in storage after removing the   
  batteries. 
 
● Do not expose the instrument to the direct sun,   
  high temperature and humidity or dewfall. 
 
● Use a cloth dipped in water or neutral detergent   
  for cleaning the instrument. Do not use abrasives   
  or solvents. 
 

 
 
 
 
 
 
 
 
 
 
 

7. Battery Replacement 
 

 

WARNING 

 

● Replace the batteries when a Low Battery   
  Voltage warning "        " mark(< 2.3±0.15V) is   
  indicated on the LCD. Otherwise, precise   
  measurement cannot be made. Note that when   
  the battery is completely exhausted, the LCD   
  goes blank without showing "        " mark. 
 
● Do not try to replace the batteries if the surface of   
  the instrument is wet. 
 
● Disconnect the test leads from the object under   
  test and power off the instrument before opening   
  the Battery Compartment Cover for Battery   

 

replacement. 

 

 

 

CAUTION 

 

● Do not mix old and new batteries. 
 
● Install batteries in correct polarity as indicated in   
  the battery compartment. 

 

 

(1) Set the Function switch to "OFF" position. 

 

(2) Unscrew and remove the battery compartment   

 

cover on the bottom of the instrument. 

 

(3) Replace the batteries observing correct polarity.   

 

Use new two R03/LR03 (AAA) 1.5V batteries. 

 

(4) Install the battery compartment and tighten the   

 

screws. 

 

 

 

 

 

 

 

 

 

 