This symbol, adjacent to another symbol or terminal, indicates the user 
must refer to the manual for further information.

This symbol, adjacent to a terminal, indicates that, under normal use, 
hazardous voltages may be present.

Double insulation.

Application around and removal from uninsulated hazardous live 
conductors is permitted. 

1. SAFETY

!

1.1. lnternational Safety Symbols

1.2. Safety Notes

•  Do not exceed the maximum allowable input range of any function.

•  Do not apply voltage to meter when resistance function is selected.

•  Set the function switch OFF when the meter is not in use.

•  Remove the battery if meter is to be stored for longer than 60 days.

1.3. Warnings

•  Set function switch to the appropriate position before measuring.

•  When measuring volts do not switch to current/resistance modes.

•  Do not measure current on a circuit whose voltage exceeds 600V.

•  When changing ranges always disconnect the test leads from the circuit 

under test.

1.4. Cautions

•  Improper use of this meter can cause damage, shock, injury or death. 

Read and understand this user manual before operating the meter. 

•  Always remove the test leads before replacing the battery or fuses. 

•  Inspect the condition of the test leads and the meter itself for any damage 

before operating the meter. Repair or replace any damage before use. 

•  Use great care when making measurements if the voltages are greater 

than 25VAC RMS or 35VDC. These voltages are considered a shock hazard. 

•  Always discharge capacitors and remove power from the device under test 

before performing Diode, Resistance or Continuity tests. 

•  Voltage checks on electrical outlets can be difficult and misleading because 

of the uncertainty of connection to the recessed electrical contacts. Other 
means should be used to ensure that the terminals are not "live". 

•  If the equipment is used in a manner not specified by the manufacturer, 

the protection provided by the equipment may be impaired. 

A AC  

   

600A AC 

V DC, V AC  

   

1000V DC/AC 

Resistance, Capacitance, Frequency,  

250V DC/AC 

Diode Test, Temperature.  

Maximum Input

Function

Summary of Contents for MTD70T

Page 1: ...MTD70T 600A AC TRUE RMS DIGITAL CLAMP METER INSTRUCTION MANUAL...

Page 2: ...2...

Page 3: ...ue RMS 7 4 3 DC Voltage 7 4 4 Resistance 7 4 5 Diode and Continuity 8 5 Operation 8 5 1 AC Current Measurements 8 5 2 AC Voltage Measurements 9 5 3 DC Voltage Measurements 9 5 4 Resistance Measurement...

Page 4: ...he circuit under test 1 4 Cautions Improper use of this meter can cause damage shock injury or death Read and understand this user manual before operating the meter Always remove the test leads before...

Page 5: ...Battery Cover 2 Descriptions 2 5 7 1 9 11 12 3 4 6 8 10 13 14 Button Operation Performed HOLD Data Hold Minus sign Negative reading display 0 to 3999 Measurement display digits NCV Non Contact Voltag...

Page 6: ...ge Humidity 80 Operating Altitude 2000meters 7000ft maximum Battery 2 x 1 5V AAA Battery Battery life Approx 30h backlight ON Approx 100h backlight OFF Auto power OFF After approx 15 minutes Dimension...

Page 7: ...ion 4 3 DC Voltage Accuracy of reading digits Input impedance on 200mV range 40M all other ranges 10M Overload protection 600V DC or RMS of AC Input Protection 250V DC or Peak value of AC Note a On 20...

Page 8: ...20A for low current readings 3 Press the trigger to open jaw Fully enclose only one conductor For optimum results center the conductor in the jaw 4 The clamp meter LCD will display the reading NOTES...

Page 9: ...2 Set the function switch to the position 3 Use SELECT Button to select The display icons will change when the SELECT button is pressed 4 Touch the Test Probe tips across the circuit or component unde...

Page 10: ...ly lit areas Press the button for 3 seconds to turn the Flashlight and LCD backlight on Press once again to turn the Flashlight and backlight off The both work simultaneously 5 10 Range Function Press...

Page 11: ...the meter from any circuit remove the test leads from the input terminals and turn OFF the meter before opening the case Do not operate the meter with an open case 6 2 Battery Replacement 1 When the...

Page 12: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...