2.2.4 Resistance
Range
Accuracy
Resolution
200Ω
± ( 1.0%+5 )
0.1Ω
2000Ω
± ( 1.0%+3 )
1Ω
20kΩ
10Ω
200kΩ
100Ω
2000kΩ
± (1.5%+3 )
1kΩ
Overload protection: F0.5A/600V fuse
2.2.5 Diode and Audible continuity test
Range
Description
Test condition
Display read
approximately
forward voltage
of diode
Forward DC current
approx. 10μA
Reversed DC voltage
approx. 1.8V
Built-in buzzer
sounds if
resistance is
less than 50Ω
Open circuit voltage
approx. 1.8V
Overload protection: F0.5A/600V fuse
3. OPERATION
3.1 DC Voltage Measurement
1) Connect the black test lead to the "
COM
" socket and red test lead to the
"
VΩmA
" socket.
2) Set the selector switch to desired “
V
” position.
3) Measure the voltage by touch the test lead tips to the test circuit where the
value of voltage is needed.
4) Read the result from the LCD panel. The polarity of the red lead connection will
be indicated along with the DC voltage value.
Note:
a) If the voltage range is not known beforehand, set the selector switch to high
range and work down.
b) When “1” or “-1” is display, over-range is being indicated and the selector switch
must be set to a higher range.