9. INSTALLING THE SOFTWARE

1. Start windows
2. Insert the USB into the PC or Laptop and download the software.
3. Now follow the installation program instructions.
4. Once the software is installed, switch on the meter.
5. Start the software.
8. Selected the COM port 3, note is 4.
9. If the connection is not in order, the message “NO CONNECTION” 

appears on the screen.

10. MAINTENANCE

•  The white plastic disc on the top of the detector should be cleaned with 

a damp cloth when necessary.

•  Do not store the instrument where temperature or humidity is 

excessively high.

•  The reference level, as marker on the face plate, is the tip of the photo 

detector globe.

•  The calibration interval for the photo detector will vary according to 

operational conditions, but generally the sensitivity decreases in direct 
proportion to the product of luminous intensity by the operational time.

•  In order to maintain the basic accuracy of the instrument, periodic 

calibration is recommended.

Summary of Contents for MT943

Page 1: ...INSTRUCTION MANUAL DATA LOGGING LIGHT METER MT943...

Page 2: ...2...

Page 3: ...Hold Mode 7 5 7 Maximum and Minimum Mode 7 5 8 Relative Reading Mode 7 5 9 USB Mode 8 5 10 Backlight Function 8 5 11 Setup Time and Sampling Rate 8 5 12 MEM Function 8 5 13 Data logger Function 8 6 Ba...

Page 4: ...h accuracy and rapid response Data hold function for holding measuring values Unit and sign display for easy reading Automatic zeroing Meter corrected for spectral relative efficiency Correction facto...

Page 5: ...peatability 3 Sampling Rate 1 3 times sec of analog bar graph indication 1 3times sec of digital display Datalogger sampling could be setup Photo Detector One silicon photo diode and spectral response...

Page 6: ...Display 2 USB Interface 3 UNITS Button 4 Backlight LOAD Control Button 5 RANGE Button 6 REC SET Button 7 MAX MIN Button 8 Peak Hold Button 9 REL Button 10 Data Hold Button 11 Power Button 12 Photo Det...

Page 7: ...illuminance meter stops all further measurements Press the Data Hold Button again to exit Data Hold mode then it resumes normal operation 5 6 Peak Hold Mode Press the Peak Hold Button to choose Pmax...

Page 8: ...on of setting Hold the MEM SETUP and UNITS Button to exit the setting time and sampling mode and then confirm 5 12 MEM Function Press the MEM SET Button to save the present data HOLD the LOAD Button f...

Page 9: ...filters makes the spectral sensitivity characteristic meeting C I E INTERNATIONAL COMMISSION ON ILLUMINATION Photo curve V as the following chart described 8 CONNECTING TO PC 8 1 System requirements W...

Page 10: ...white plastic disc on the top of the detector should be cleaned with a damp cloth when necessary Do not store the instrument where temperature or humidity is excessively high The reference level as m...

Page 11: ...300 14 28 Hotel Public Room Cloakroom 100 200 9 18 Reception 200 500 18 47 Cashier 750 1 000 70 93 Store Indoors Stairs Corridor 150 200 14 18 Show Window Packing Table 750 1 500 70 140 Forefront of...

Page 12: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Reviews: