Major tech MT245 Instruction Manual Download Page 18

10

18

5.  After the data is transferred to the computer, the printing software will 

display this information. For example;

 

CCA rating: 500A CCA:490

 

Internal resistance: r=6.lm 

Ω

 

Battery voltage: 12.64V

 

Battery life: 96%

 

Power percentage: 100%

 

Good battery

 

Or select 'my QR code', and press enter, and the                          
mobile phone can scan the QR code to obtain                               
measurement information.

6.  Press exit to return

3.5. Introduction To Setting Options

In the setting options, you can set the language, buzzer sound switch and 
equipment test and debugging settings:

1.  Language:

 select the desired language. Click OK in the language 

column to enter the next level of language settings, use the "up" and 
"down" buttons to select the required language, then press the 
"ENTER" button to save the selection and press the exit button to 
return to the previous menu.

2.  Buzzer: 

buzzer sound switch setting. Click the buzzer option to enter 

the next level of sound switch settings, use the "up" and "down" 
buttons to select whether the sound is on or off, then press the 
"ENTER" button to save the selection and press the exit button to 
return to the previous menu.

3.  Equipment Test:

 check the color screen RGB three colours and 

confirm whether the four operation keys are normal.

4.  Bluetooth Function:

 Activate the Bluetooth function to transfer data 

from the instrument to the APP.

 

1) Download Meterbox Pro APP to connect with the meter to get more 

functions. Search the APP name Meterbox Pro on the App Store (for 
iOS) or Google play (for android).

 

2) Select the setting option and press the ENTER key to open the menu.

 

3) Then press the "Up" and "Down" keys to select the Bluetooth setting 

option, press ENTER again to open the next menu.

 

4) Press the "Up" and "Down" keys to turn the Bluetooth function 

ON/OFF.

 

5) Press the EXIT key to exit the current menu.

Summary of Contents for MT245

Page 1: ...INSTRUCTION MANUAL CAR BATTERY TESTER MT245...

Page 2: ...2...

Page 3: ...tions 5 2 3 Accessories Included 6 3 Operating Instructions 6 3 1 Usage and Operation 6 3 1 1 In Vehicle Battery Test 7 3 1 2 Battery Out Of Vehicle 9 3 1 3 Starting System Test 12 3 1 4 Charging Syst...

Page 4: ...t and other additional functions Battery test is mainly targeted to analyze the battery healthy status to calculate the actual cold cranking capability of the battery and the aging extent which provid...

Page 5: ...range 8V 30V DC Support USB printing connected to the computer Support QR code the mobile phone can scan QR code to obtain test results 2 PRODUCT INFORMATION 2 1 Tool Description Up Down Button Select...

Page 6: ...use cancer birth defects or other reproductive hazards Wash hands after treatment 4 Power provided via cable from car battery 5 Dimensions LxWxH 784mm x 355mm x 210mm 6 Weight 293g 2 3 Accessories Inc...

Page 7: ...charge turn on the lamp Turn on the lamp as prompted to remove the battery surface charge and the tester will display the following messages in sequence Battery test 1 Select Battery Type After select...

Page 8: ...s displayed on the battery in combination of numbers and letters such as 55d23 and 80d26 DIN Standards of German automobile industry committee IEC Internal electronic technical committee standards EN...

Page 9: ...5D31L 565 95E41L 475 105D31L 655 105E41L 540 115E41L 610 115F51 575 130E41L 680 145F51 735 145G51 685 150F51 765 165G51 710 170F51 925 180G51 860 190H52 765 195G51 930 210H52 910 245H52 1170 3 1 2 Bat...

Page 10: ...the UP DOWN keys to select the rated capacity of the battery and press ENTER to confirm The meter starts the test displays the battery test results after 2 seconds The battery test results include the...

Page 11: ...circuited replace the battery 5 Charge Retest CCA rating 500A CCA 490 Internal resistance r 30 lm Battery voltage 12 08V Battery life 39 Power percentage 20 Unstable batteries should be recharged and...

Page 12: ...e climb test is normal and the test result example 1 is displayed Climb test Time 6810ms Maximum 11 55V Minimum 10 24V The starting voltage is normal 2 When the climb test is abnormal the test result...

Page 13: ...d to more than 2500rpm and click the ENTER key of the instrument to start the charging test Test result if the charging voltage reading is greater than 15 5V please check the voltage regulator If the...

Page 14: ...throttle to increase the engine speed Charging test Increase the speed to 2500rpm Hold for 5 seconds Press OK to continue Operate accordingly to increase the engine speed to 2500rpm or above for 5 sec...

Page 15: ...rding to the manufacturer s recommendations 3 Charging voltage high The generator output voltage is high Since most automotive generators use internal regulators the generator assembly must be replace...

Page 16: ...r 11V it means the battery is aging and replacement is needed Starting Voltage During ignition the voltage will drop to a certain point at this minimum point is Starting Voltage Around 7 5 9 5V If the...

Page 17: ...d down buttons to select on the playback icon and press enter Use the up and down buttons to select the data saved during the previous test and the waveform diagram for starting the test and then pres...

Page 18: ...turn to the previous menu 2 Buzzer buzzer sound switch setting Click the buzzer option to enter the next level of sound switch settings use the up and down buttons to select whether the sound is on or...

Page 19: ...nstrument Please contact the local service office 4 1 Cleaning If the tester needs to be cleaned after daily use use a damp cloth and mild household detergent Before cleaning disconnect the tester fro...

Page 20: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Reviews: