![Major tech MT1885 Instruction Manual Download Page 17](http://html1.mh-extra.com/html/major-tech/mt1885/mt1885_instruction-manual_3793459017.webp)
Range
Resolution Accuracy
0.1%~99.9% 0.1%
±
1.2% of reading
±
2 dgts
8.9. DUTY CYCLE
Pulse width: >100us, <100ms;
Frequency width: 5Hz – 150 kHz
Overload protection: 250V DC/AC RMS.
17
Range
Resolution
Accuracy
10.00~1KHz 0.01Hz
±(1.5% reading)
8.8. FREQUENCY (ELECTRICAL)
Sensitivity: ACV Range (
≥
6% Range), 6000μA/600.0mA Range
(
≥
6%Range), 600.0μA/60.00mA/10.00A (
≥
60% Range).
Range
Resolution Accuracy
9.999Hz
0.001Hz
±(1.2% reading
±
4 digits)
99.99 Hz 0.01Hz
999.9 Hz 0.1Hz
9.999KHz 1 Hz
99.99kHz 10Hz
999.9kHz 100Hz
9.999MHz 1kHz
8.7. FREQUENCY (ELECTRONIC) (AUTO-RANGING)
Sensitivity: 0.8V RMS min. at 20% to 80% duty cycle and <100kHz;
5VRMS min at 20% to 80% duty cycle and >100kHz.
Input Protection: 250VDC/AC RMS.
Range
Resolution
Accuracy
-20.0°C ~+599.9°C 0.1 °C
±3.0% of rdg
±
5°C
600°C ~+1000°C
1°C
Meter only, probe accuracy not included
-4.0°F ~+599.9 °F
0.1°F
±3.0% of rdg ± 9°F
600°F ~+1832°F
1°F
Meter only, probe accuracy not included
8.10. TEMPERATURE
Sensor: Type K Thermocouple
Overload protection: 250VDC/AC RMS.
Summary of Contents for MT1885
Page 1: ...INSTRUCTION MANUAL 1500V DC MULTIMETER IV MT1885...