Major Science MJ-105-S Instruction Manual Download Page 5

of explosion, implosion or release of toxic or flammable gases arising from 

overheated materials. 

11. The unit shall be operated only by qualified personnel.

Safety Information 

Use high level of precaution against any electrical device. Before connecting 

the electrical supply, check to see if the supply voltage is within the range 

stated at the rating label, and see to it that the device be seated firmly. Place 

the unit in a safe and dry location; it must NOT touch the surrounding. Follow 

the safety precautions for chemicals / dangerous materials. If needed, please 

contact qualified service representative o

[email protected]

 

Environmental Conditions 

Ensure that the instrument is installed and operated strictly under the following 

conditions: 

1.

Indoor use only

2.

≤95% RH

3.

75 kPa 

– 106 kPa

4.

Altitude must not exceed 2000 meters

5.

Ambient to 40°C operating temperature

6.

Pollution degree: 2

7.

Mains supply voltage fluctuations up to ±10% of the normal voltage

Avoiding Electrical Shock 

Follow the guidelines below to ensure safe operation of the unit. 

To avoid electrical shock: 

1. NEVER connect or disconnect wire leads from the power supply unit when

the power supply unit is still on.

2. WAIT at least 5 seconds after stopping a run before handling output leads

or connected apparatus.

3. ALWAYS make sure that hands, work area, and instruments are 

clean

 and

dry

 before making any connections or operating the power supply.

DOMINIQUE 

DUTSCHER SAS

Summary of Contents for MJ-105-S

Page 1: ...Mini Horizontal Electrophoresis System Instruction Manual Catalog No MJ 105 S MJ 105 R MT 108 Version 01E Date 2014 3 20 D O M I N I Q U E D U T S C H E R S A S...

Page 2: ...i Electrophoresis Tank Cover 1x Gel Maker Stand 1x 105 x 83 mm Tray 2x 50 x 83 mm Tray 1x Double Side Comb 6 teeth x 2 12 teeth Prep 1 Marker 2 Prep2 Marker 2 23 teeth 1x Double Side Comb 8 teeth x 2...

Page 3: ...scription 6 Section 2 Technical Specifications 8 Section 3 Installation Instructions 9 Section 4 Operation Instructions 10 4 1 Controls and Features 10 4 2 Start the operation 10 Section 5 Maintenance...

Page 4: ...is strongly recommended for the user to read the following points carefully before operating this equipment 1 Read and follow the manual instructions carefully 2 Do not alter the equipment Failure to...

Page 5: ...Environmental Conditions Ensure that the instrument is installed and operated strictly under the following conditions 1 Indoor use only 2 95 RH 3 75 kPa 106 kPa 4 Altitude must not exceed 2000 meters...

Page 6: ...rs should check with the manufacturer s instruction to see if the proposed method will damage the equipment Equipment Operation Follow the guidelines below to ensure safe operation of the unit 1 NEVER...

Page 7: ...or very fast and clear separation of DNA or RNA restriction fragments This series is offered as a complete system including all the necessary accessories for the user to cast run and perform electroph...

Page 8: ...of agarose gel in one time for MT 108 High temperature capability 130 C Easy sample loading Great indications for gel making and running No tapes clamps or springs needed D O M I N I Q U E D U T S C...

Page 9: ...PC Polycarbonate Construction Material Transparent Lid AS Acrylonitrile Styrene Copolymer Temperature Capacity 130 C Unit Dimension Tank and Transparent Lid 140 x 140 x 53 mm W x L x H Gel Dimension T...

Page 10: ...Black well visualization strip Migration distance index line Rapid Casting Gel Use gel maker stand Operating Temperature 4 40 C Weight 0 7 kg Section 3 Installation Instructions 1 Seat the tray in th...

Page 11: ...esired ratio 2 Dissolve the agarose powder by heating the agarose either on a magnetic hot plate with a stirring bar or in a microwave oven If using the microwave method the microwave should be set at...

Page 12: ...for a large tray pour 12 to 15 ml for a small tray The tray contains the agarose level for reference Note Pour the agarose carefully so as not to generate bubbles Any bubble that surfaces could be smo...

Page 13: ...ly connect the power cords to the power supply unit 5 Turn on the power supply unit and adjust to the desired electrophoresis running conditions 6 When the electrophoresis running is complete turn the...

Page 14: ...tes After that rinse with distilled water Air dry before use Some cleaning agents are not supposed to come in contact with the electrophoresis systems such as Acetone Phenol Chloroform Alcohol and Alk...

Page 15: ...phoresis Packages MJSS Mini300 Package of 2 x MJ 105 S and Mini 300 MJRR Mini300 Package of 2 x MJ 105 R and Mini 300 MTT Mini300 Package of 2 x MT 108 and Mini 300 MJSR Mini300 Package of MJ 105 S MJ...

Page 16: ...01 MT CASTER C contains 1 x MT G01 1 x MT T01 2 x MT 02 1 x MT C03 and 1 x MJ C01 Single Electrophoresis Packages MJS Mini300 MJR Mini300 MT Mini300 Dual Electrophoresis Packages MJSS Mini300 MJRR Min...

Page 17: ...the warranty is limited to the receipt of reasonable proof by the customer that the defect is embraced within the terms of the warranty All claims made under this warranty must be presented to Major S...

Page 18: ...17 MEMO D O M I N I Q U E D U T S C H E R S A S...

Page 19: ...18 MEMO D O M I N I Q U E D U T S C H E R S A S...

Page 20: ...19 MEMO D O M I N I Q U E D U T S C H E R S A S...

Reviews: