VF/VFR Vent-Free Fireboxes

GENERAL INSTALLATION INFORMATION

The VF-TB and VF-R Series are vent-free fireboxes. They 

feature  a  self  contained  heat-circulating  system. These 

units  also  feature  a  -in1,  flexible-face  system,  sold  as 

an accessory, that converts the circulating system into a 

radiant system in seconds. 
This installation manual will enable you to obtain a safe, 

efficient  and  dependable  installation  of  your  vent-free 

fireplace system.
Do not alter or modify the firebox or its components under 

any circumstances.  Any modification or alteration of the 

firebox system, including but not limited to the firebox and 

accessories, may void the warranty, listings and approvals 

of this system and could result in an unsafe and potentially 

dangerous installation.

BEFORE YOU START 

Carefully inspect the contents for shipping damage. If any 

parts  are  missing  or  damaged,  immediately  inform  the 

dealer from whom you purchased the appliance. Do not 

attempt to install any part of the appliance unless you have 

all the parts in good condition. 

MAkE SURE YOU HAVE RECEIVED ALL 

pARTS

 

Check your packing list to verify that all listed parts have 

been received. You should have the following: 
1.  Vent-Free Gas Firebox
.  Canopy 
3.  Installation and Operating Instructions
4.  Five (5) sheet metal screws for canopy

WHAT YOU WILL NEED FOR INSTALLATION

TOOLS and BUILDING SUppLIES

  Phillips screwdriver 

  Square 

  Framing materials 

  Hammer

  Saw and / or saber saw 

  Tee joint

  Level 

  Pipe wrench

  Measuring tape 

  Pliers

  Electric drill and bits

  Fireplace surround materials 

(noncombustible)

  Caulking material 

(noncombustible)

  Wall finishing materials

  Piping complying with local codes

  Pipe  sealant  approved  for  use  with  propane/L.P.G. 

(resistant to sulfur compounds)

Refer to the installation instructions provided with the log 

sets for items required for log set installation.

In planning the installation for the appliance it is necessary 

to determine where the unit is to be installed and whether 

optional accessories are desired. Gas supply piping should 

also be planned. The following steps represent the normal 

sequence of installation.  Each installation is unique, how-

ever, and might require a different sequence.
1.  Position firebox prior to framing or into prepared fram-

ing.

.  Field wire main power supply to models with fan kit. 

(Electrical connections should only be performed by an 

experienced, licensed /certified tradesman).

3.  Plumb gas line. (Gas connections should only be per-

formed  by  an  experienced,  licensed/certified  trades-

man).

4.  Install  vent-free  gas  log  heater  per  the  instructions 

provided with the vent-free gas log heater.

5.  Complete  finish  wall  material,  surround  and  optional 

hearth extension to your individual taste.

Summary of Contents for VF

Page 1: ...plier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNINGS For...

Page 2: ...ctions may result in a possible fire hazard and will void the warranty Important Safety Information 3 General Installation Information 5 Before You Start 5 What You Will Need for Installation 5 Firebo...

Page 3: ...PORTANT SAFETY INFORMATION 8 CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air i...

Page 4: ...he control system and any gas control which has been under water 25 Never burn solid fuels in a fireplace where a unvented room heater is installed 26 Always have a fireplace screen in place when the...

Page 5: ...Instructions 4 Five 5 sheet metal screws for canopy What you will need for installation TOOLS and BUILDING SUPPLIES Phillips screwdriver Square Framing materials Hammer Saw and or saber saw Tee joint...

Page 6: ...6M 6 1 6QE 5 6QE N 21 6M E H J L G K Ref VF VFR32C VF VFR36C VF VFR42C A 37 41 47 B 32 36 42 C 16 18 18 D 29 32 38 E 18B 20B 20B F 23C 27C 33C G 13Z v 15C v 15C v H 18 17B 17B I 29M 34 40 J 7Z 9C v 9C...

Page 7: ...ing fans return air registers for forced air furnaces air conditioners windows or doors Installation must provide adequate ventilation and com bustion air DO NOT INSTALL THIS FIREBOX IN A BEDROOM OR B...

Page 8: ...wall MINIMUM CLEARANCES 9 Minimum 42 Minimum 9 Minimum FP2687 minimum clearances FP2687 Figure 4 Clearance and Height Requirements 4 Mantel clearances The canopy supplied with the unit must be instal...

Page 9: ...tion noncombustible material includes but is not limited to stone brick and mortar Noncombustibles are safe to overlay the black painted metal face including radiant plates and do not pose a fire haza...

Page 10: ...igure 11 Installing Canopy FP2451 install canopy Screws Canopy FP2451 WARNING The firebox canopy must not be modified or replaced with a canopy that may be provided with the unvented decorative room h...

Page 11: ...rough trap to the heater controls and burners Failure to do so could prevent the heater from operating reliably Consult appli cable codes An external regulator must be used on all propane L P G heater...

Page 12: ...rom any ap pliance vent terminal 6 Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly These conditions increase the resistance to the fr...

Page 13: ...OA start collar 8 08 Figure 16 Attach Outside Air Starting Collar and Insulation Ring to Left Side of Fireplace Insulation Ring AK 4 Starting Collar Sheet Meal Screws Left Side of Fireplace Shorter En...

Page 14: ...Note If the wall covering is brick or stone use appropriate masonry fasteners If necessary splice the duct Use a model 403 duct connector to splice duct sections Install model 403 duct connector 1 Pus...

Page 15: ...be installed in place of the factory installed black louvers Refer to installation instructions provided with the brass or pewter louvers OPTIONAL Trim Optional trim kits can be used with unit when in...

Page 16: ...1 Wide Brass Canopy 1 BRC32 BRC36 BRC42 4 Brass Louver 1 L32BR L36BR L42BR 4 Pewter Louver 1 L32PW L36PW L36PW 5 Blower w Rheostat 1 BLOTMC BLOTMC BLOTMC 6 Brass Trim Curved Design 1 BRTK32C BRTK36C B...

Page 17: ...17 71D0531 VF VFR Vent Free Fireboxes...

Page 18: ...71D0531 18 VF VFR Vent Free Fireboxes...

Page 19: ...ons The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox...

Page 20: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Reviews: