Page 1: ...OR USE GASOLINE OR OTHER Do not use any phone in your building FLAMMABLE VAPOURS OR LIQUIDS Immediately call your gas supplier from IN THE VICINITY OF THIS OR ANY your neighbours phone Follow the gas...

Page 2: ...ormation 7 Termination Location 7 General Information on Assembling Vent Pipes 9 Vertical Sidewall Installations 10 Vertical Sidewall Applications 10 Sidewall Venting Graph 11 Vent Pipe Assembly 12 Be...

Page 3: ...orations be hung on or around the fireplace 9 Under no circumstances should any solid fuels wood coal paper or cardboard etc be used in this fireplace 10 The flow of combustion and ventilation air mus...

Page 4: ...Dimension Table A 26 25 in 667 mm B 31 75in 806mm c 19 38 in 492 mm 0 30 25 in 768 mm E 10 25 in 260 mm F 15 5 in 394 mm G 4 75 in 121 mm H 26 25 in 667 mm I 13 13 in 334 mm J 19 38 in 492 mm K 6 5 in...

Page 5: ...0 0 WC Manifold Pressure 3 5 WC 10 0 WC A The use ofwallpaper adjacent to thisfireplace is not recommended as the high heat given off by thisfireplace may adversely effect the bind ers in the adhesive...

Page 6: ...E IFANY PART OF THIS FIREPLACE HAS BEEN UNDER WATER IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE HEATER AND TO REPLACE ANYPART CONTROL WHICH HAS BEEN UNDER WATER The remote ON OFF sw...

Page 7: ...snow falls and clear to prevent accidental blockage of venting systern When using snow blowers make sure snow is not directed towards vent termination area Location of Vent Termination It is imperativ...

Page 8: ...n I Fig 6 Fig 7 Balcony with no side wall G G Combustible Non Combustible 12 305mm Fig 8 Balcony with perpendicular side wall Combustible Non Combustible H 24 610mm J 20 508mm J Fig 9 0001948 1 Page 8...

Page 9: ...nly venting components manufactured by The CFM Majes tic Products Company may be used When using CFM Majestic twist lock pipe it is not necessary to use sealant at the twist lock joints The only areas...

Page 10: ...wall installation is three 3 For RFSDV34 models the maximum horizontal run offa minimum 12 vertical rise is 3 See Fig 15 If a 90 degree elbow is used in the horizontal vent run level height maintaine...

Page 11: ...floor ofthe fireplace is 11 feet 335cm the horizontal run to the face ofthe outer wall must not exceed 14 feet 427cm EXAMPLEB Ifthe vertical dimension from the floor ofthe fireplace is 7 feet 214cm th...

Page 12: ...to proper length MAXIMUM 12 Assemble sleeve and attach to firestop with 8 sheet metal screws supplied Install firestop assembly Fig 18 Zero clearance sleeve combustible walls is only required for 8 M...

Page 13: ...nd 7 collars or the termination one inch away from crimped end Guide the vent terminations 4 and 7 collars into their respective vent pipes Double check that the vent pipes overlap the collars by 2 Se...

Page 14: ...center ofthe snorke may be includecffpr calculation ofmax horizontal run Fig 24 DO NOT BACK FILL AROUND SNORKEL A CLEARANCE OF ATLEAST4 MUST BE MAINTAINED BETWEEN THE SNORKEL AND THE SOIL lfthe found...

Page 15: ...um of l inch clearance to the vent pipe i e the hole must be at least 9 3 8 x 9 3 8 240 mm x 240 mm 5 Place fireplace into position 6 Place firestop s 7DVFS or Attic Insulation Shield 7DVAIS into posi...

Page 16: ...7DVRT90 for Vertical Sidewall Applications or thru the roof Telescopic vent sections 7DVP6lO 6 to 1O adjustable length 7DVP1018 10 to 18 adjustable length 7DVP1834 18 to 34 adjustable length 7DVP3466...

Page 17: ...Installation Offsets 90 transition elbow kit 7TFSDV90 for Vertical Sidewall Applications or thru the roof Telescopic vent sections 7TDVP1218 12 to 18 adjustable length 7TDVP3564 35 to 64 adjustable le...

Page 18: ...mmended that the glass be cleaned two or three times with a non ammonia household cleaner and warm water we recommend gas fireplace glass cleaner After that the glass should be cleaned two or three ti...

Page 19: ...All adf11stments on 11nitsfitted with the Honeywell Radio Fre q11ency control valve areperformed with the remote transmit ter See instructions packaged with the transmitter or the addendum pages in th...

Page 20: ...mote Control MRC2 Temperature Control Remote MRC3 Temperature Control w digital display 24 hour programmable clock IMT Wall Mounted Thermostat A decorative brass window trim kit Model RFSDV34TKA is av...

Page 21: ...he main burner 9 Turn knob on gas control counter clockwise to PILOT 1 Turn the On Offswitch to Offposition or set the thermostat to lowest setting 2 Turn off all electric power to the fireplace if se...

Page 22: ...le Clean and or adjust pilot for maximum flame impingement instructions on thermocouple B Defective automatic valve Tum valve knob to Pilot Maintain flow to pilot mil operator livolt meter should read...

Page 23: ...TIONS REPLACE PIEZO IGNITOR FOR AIR IN THE LINES THERMOPILE NEEDS A MINIMUM 325mV ADJUST PILOT FLAME HEIGHT PILOT STAYS LIT ALL WIRING CONNECTIONS NO REPLACE THERMOPILE THERMOCOUPLE NEEDSA YES PILOT L...

Page 24: ...burning no gas to A Wall switch or wires defective Check wall switch and wires for proper connections Jumper wire across terminals at wall switch ifburner Wall comes on replace defective wall switch...

Page 25: ...b Pilot Assembly Top Convertible Prop 10002265 13a Pilot Assembly Radio Frequency Nat 20002266 13b Pilot Assembly Radio Frequency Prop 20002268 14 Pilot SIT 10001295 15 Pilot with Electrode Cable PSE...

Page 26: ...iring Harness Remote Switch 57265 42 Remote ON OFF Switch Kit includes bracket 53859 43 Window Frame Assembly complete with glass 10001917 44 Window Glass Replacement Kit 10001916 45 Window Glass Gask...

Page 27: ...0a b 12a b 35 0 3 6 50 15 r _ i H _ _ I i c 1 40 I s c 46 47 i lb 111 11 1 43 30a b 10001948 1 Page 27 26a 26a 23 l 14 0 27 t 19 19 18 26a 4 25 20 21 29...

Page 28: ...es checked annually More frequent cleaning may be required due to excess lint and dust from carpeting bedding material etc 6 Control compartments burners and air passages in this fireplace should be k...

Page 29: ...the conversion screw refer to the instructions and diagrams in the Honeywell Installation Instructions supplied in the conversion kit packaged with the RFSDV34RMH unit I0 Reassemble the fireplace in...

Page 30: ......

Reviews: