background image

19

ODSHR  Outdoor Woodburning Fireplace

20002264

 

*  Two (2) required

  **  Four (4) required

CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, 
without notice.

2264pts

odshr

replacement parts

1/5/00   djt

1

2

5

7

6

4

3

12

11

8

10

9a,b

13

 

Ref.  Description 

Part Number

 

1.  Damper Blade 

3990185

 

2.  Damper Handle 

20001418

 

3.  Screen Rail 

20002262

 

4.  Screen Rod 

20002222

 

5.  Screen (two per fireplace) 

20002223

 

6.  Screen Pull (two per fireplace) 

20002225

 

7.  Push Nut (two per fireplace) 

7512167

 

8.  Firebrick - Back 

20004155

  9a.  Firebrick - Left Side 

20004157

  9b.  Firebrick - Right Side 

20004156

  10.  Firebrick - Hearth 

20000816

  11.  Firebrick Retainers 

20002260

  12.  Grate 

20002230

ODSHR Outdoor Woodburning Fireplace

Summary of Contents for Vermont Castings ODSHR42

Page 1: ...djt Homeowner s Installation and Operating Manual DO NOT DISCARD THIS MANUAL Retain for future use 20002264 10 06 Rev 17 Model ODSHR42 Underwriter s Laboratories Report No MH20546 ODSHR Series Outdoor...

Page 2: ...re hazard and will void the warranty Safety Information 2 Speci cations and Framing Dimensions 3 Hearth Dimensions 4 Chase Installations 5 Freestanding Installation 5 Chimney Requirements 6 Planning...

Page 3: ...e replace to cook or warm food Do not obstruct or modify air inlets outlets in any manner Do not install combustible materials on any of the replace surround Burn only solid wood fuel or gas logs Do n...

Page 4: ...Air Gas Line Access Gas Line Access 62 1578 mm 340 mm 279 mm Fig 1 ODSHR42 Series speci cations and framing ODSHR42 Series Woodburning Fireplace A B C FP1531 hearth dimensions 9 04 djt Front Width Ba...

Page 5: ...FP1001 fireplace setting 1 4 00 djt NOTE If the replace is a free standing unit it must be located a minimum of 10 3 m from the opening of the rebox to a com bustible structure A minimum height of 6...

Page 6: ...ured from the hearth to the chimney exit ODSHR42 Maximum 90 27 4 m Minimum Without Elbows 14 6 4 4 m With 2 Elbows 15 6 4 7 m With 4 Elbows 21 0 6 4 m B Do not use more than 4 elbows per chimney Attac...

Page 7: ...will be set and how the chimney system will be run Mounting the Fireplace A replace may only be mounted on the following sur faces 1 A at combustible surface 2 A raised wooden platform 3 A concrete bl...

Page 8: ...e in a cold climate it is not required but highly recommended that you insulate replace enclosure to eliminate cold air penetration as much as possible Insulate base of replace with a noncombustible i...

Page 9: ...CK THE END CONNECTION OF CHIMNEY SECTIONS AND ELBOWS NOTE ODSHR Series Fireplaces must use CFM Cor poration model 11CF 11 inch 2 wall chimney systems The installation procedure described in this manua...

Page 10: ...bers Chimney Hole Size FP551b SHR 5 11 99 djt New Framing Members Existing Ceiling Joists Chimney Hole 17 445 mm 17 445 mm FP551b Fig 13 Typical frame for ceiling chimney hole Fig 12 Ceiling chimney h...

Page 11: ...re place are noncombustible Four 4 nailing anges are supplied with the replace found on the replace hearth To level the box and secure it rmly in place remove the nailing anges from the hearth and ins...

Page 12: ...o chimney pipe for ceiling thickness up to 8 203 mm When combined thickness of ceiling material ceiling joists and ooring material exceeds 8 203 mm adjust ments must be made in framing to assure that...

Page 13: ...ize of roof hole There must be a 2 51 mm air space between out ermost portion of chimney sections and any adjacent combustible surfaces Combustible surfaces include burnable materials such as ceiling...

Page 14: ...djt Air Space Clearances Combustible framing material MUST NOT pen etrate AIR SPACE shaded areas Standoff 2 Air Space to Sides Firestop Front View Side View Wall Shield Air Space to Back Air Space to...

Page 15: ...ff Noncombustible Material Surround Face Fireplace Opening Noncombustible Facing Material Must be sealed with non combustible material Ledge Bracket Finished Wall 2 x 4 Stud Finished Wall Must be seal...

Page 16: ...ensions FP838 Minimum Wall Clearances WITH Noncombustible Surround Facing WITHOUT Noncombustible Surround Facing Minimum Hearth Extension Dimensions for On Site Construction 12 20 12 66 Seal cracks be...

Page 17: ...acent combustible side walls and hearth extension dimensions FP1171 sealing detail 12 20 01 djt Wall Covering 2 x 4 Header Do Not Notch at Ledge Brackets Fig 20 Hearth Extension Hearth Extension Insul...

Page 18: ...place Surround and Wall Materials with Noncombustible Material Noncombustible Decorative Cover ing Majestic Safety Strips Must be Overlapped 1 2 Min Seal Crack Between Fire place and Hearth Exten sion...

Page 19: ...djt 1 2 5 7 6 4 3 12 11 8 10 9a b 13 Ref Description Part Number 1 Damper Blade 3990185 2 Damper Handle 20001418 3 Screen Rail 20002262 4 Screen Rod 20002222 5 Screen two per replace 20002223 6 Scree...

Page 20: ...ustion in the rebox This accessory must be installed before replace is installed Located on the oor in front of replace to protect the oor from heat hot embers ashes etc Used to patch cracks in hearth...

Page 21: ...se with CF11 pipe RLTCF11L 11 ue 11CF1 1 long 11CF18 1 long 11CF3 3 long 11CF4 4 long 11CF30 2 11 30 ue S20BR BT BW S20UB Upper Baf e 20002673 FS2100 HT Contact the CFM Corporation with questions con...

Page 22: ...22 ODSHR Outdoor Woodburning Fireplace 20002264...

Page 23: ...y is extended only to a Fireplace installed in the continental United States the state of Alaska and Canada only if and so long as the Fireplace is installed according to the in stallation instruction...

Page 24: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...