Majestic NVC36 Installation And Homeowners Operating Instructions Download Page 9

9

NVC Series B-Vent

20000194

Fig. 9

  Firestop/draftstop positions.

Ceiling Installation

FP384 

FIRESTOP

11/21/96

adapted from IGF53

Attic Installation

Firestop position when area above ceiling is an attic.

Firestop position when area above ceiling is NOT an attic.

(Firestop/draftstop 

appearances may 

vary. Only 1 firestop 

required per frame.)

Firestop

Spacer

Nails (4)

Joist

FP384

Table 1

  Venting configurations.

FP567a
NVBR/NVBC VENTING RUNS
11/12/97

Venting Runs 

40
38
36
34
32
30
28
26
24
22
20
18
16
14
12

 8    9   10   11  12

3    4    5     6    7

Horizontal Run (in feet)

Ve

rtical Run (in feet)

(Measured from floor of unit tocenter of hor

izontal v

ent pipe

.)

A

A: 

Vertical installations up to 40 feet (12m) in 

     height. Up to a 8 ft. horizontal vent run can be

     installed within the vent system using a 

     maximum of two 90-degree elbows or four 

     45-degree elbows.

B: 

Vertical installations up to 40 feet (12m) in 

     height. Up to a 12 ft. horizontal vent run can be

     installed within the vent system using a 

     maximum of two 45-degree elbows. 

B

= Acceptable venting configuration
= Unacceptable venting configuration

FP567a

Summary of Contents for NVC36

Page 1: ...ust be performed by a quali ed installer service agency or the gas supplier Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAF...

Page 2: ...n 7 Remote Switch Installation 7 Alternate Switch Location 7 EB 1 Electrical Box 8 Install Venting System Flashing and Termination 8 Operating Instructions Glass Information 10 General Maintenance 10...

Page 3: ...nder no circumstances should any solid fuels wood coal paper or cardboard etc be used in this appliance 10 The ow of combustion and ventilation air must not be obstructed in any way 11 Whether the app...

Page 4: ...ons Ref NVC36 NVC39 NVC43 Framing Dimensions A 36 927 mm 39 1003 mm 43 1105 mm B 34 883 mm 35 889 mm 37 953 mm C 14 362 mm 16 419 mm 16 419 mm Appliance Dimensions D 36 914 mm 39 991 mm 43 1092 mm E 2...

Page 5: ...C D E V W X Y Z Fireplace CFM146 DV Mantel Chart 7 5 01 sta Ref Mantel Ref Mantel From Top Shelf Depth of Comb Chamber V 10 254 mm A 19 495 mm W 8 203 mm B 17 444 mm X 6 152 mm C 15 394 mm Y 4 101 mm...

Page 6: ...levations above 4 500 feet 1 370m in USA installations must be in accordance with the current ANSI Z223 1 NFPA 54 and or local codes having jurisdiction In Canada please consult provincial and or loca...

Page 7: ...gas control is equipped with a captured screw type pressure test point therefore it is not necessary to pro vide a 1 8 test point up stream of the control When using copper or ex connector use only ap...

Page 8: ...crew polarized of the socket assembly 6 Connect the white wire of the power line to the chrome screw of the socket assembly 7 Connect the ground wire of the supply line to the green screw of the socke...

Page 9: ...1 12 97 Venting Runs 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 8 9 10 11 12 3 4 5 6 7 Horizontal Run in feet Vertical Run in feet Measured from floor of unit tocenter of horizontal vent pipe A A Ve...

Page 10: ...h a non ammonia household cleaner and warm water gas replace glass cleaner is recom mended After initial use glass should be cleaned two or three times during heating season Clean glass after rst two...

Page 11: ...13 or 14 L O HI Turn counterclockwise to decrease flame height Turn clockwise to increase flame height HV102 Honeywell hi lo knob 4 5 99 djt Fig 13 Flame adjustment knob for Honeywell valve HV102 Tur...

Page 12: ...Any foreign objects in the venting system except those designed speci cally for the venting system may cause spillage of ue gases To inspect the venting system make sure the main gas valve is off Remo...

Page 13: ...all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace Do not t...

Page 14: ...e sensor Reset the sensor by pressing the reset pin between the two wire terminals Fig 18 CAUTION The components may still be hot Light the replace and check for downdrafts Operate the replace in the...

Page 15: ...ting or buckling Take protective actions to shield cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check electrical connections betwee...

Page 16: ...o Ignitor Supply Line Hooked Up Shutoff Valve Open Pilot Stays Lit For Air In The Lines Thermopile Needs A Min 325mv Adjust Pilot Flame Height All Wiring Connections Replace Thermopile Thermocouple Ne...

Page 17: ...ir in the Lines Thermopile Needs a Minimum 325Mv Adjust Pilot Flame Height All Wiring Connections Replace Thermopile Thermocouple Needs a Minimum of 14Mv Pilot Lights With Piezo Ignitor YES YES YES YE...

Page 18: ...ment It is important to keep the burner and the burner compartment clean At least once per year the logs and lava rock ember material should be removed and the burner compartment vacuumed and wiped ou...

Page 19: ...oration reserves the right to make changes in design materials speci cations prices and discontinue colors and products at any time without notice NVC36 39 43 Ref Description NVC36 NVC39 NVC43 1 Log S...

Page 20: ...sformer VN VP EN VP 7522409 7522409 7522409 20 Ignition Device Synetek EN EP 57899 57899 57899 21 Ignition Device Honeywell EN EP 20000005 20000005 20000005 22 Sensing Electrode EN EP 57885 57885 5788...

Page 21: ...nt access 4 The power supply may be connected in 2 ways Method A route the 6 1 8m lead tted to the unit to a conveniently located wall socket Method B If the EB 1 receptacle box Pt ZA1200 was correctl...

Page 22: ...the studs located in the top of the rebox toward the front cor ners 6 Place the rear refractory panel in place Locate the small brick edge of the panel into the two small supports on the back panel j...

Page 23: ...mation for the trim kits applicable to this model appliance Decorative Bay Windows When tting the Bay Window Kits the original front frame glass assembly MUST remain in place The Bay Window kit is tte...

Page 24: ...24 NVC Series B Vent 20000194...

Page 25: ...25 NVC Series B Vent 20000194...

Page 26: ...26 NVC Series B Vent 20000194...

Page 27: ...damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty...

Page 28: ...Ef ciency Ratings Model EnerGuide Ratings Fireplace Ef ciency NVC36RN 29 4 NVC36RP 29 4 NVC36RFN 29 4 NVC36RFP 29 4 NVC36EN 28 5 NVC36EP 28 5 NVC39RN 26 4 NVC39RP 26 4 NVC39RFN 26 4 NVC39RFP 26 4 NVC3...

Reviews: