background image

22

Majestic  •  MERIDPLA36IN, MERIDPLA36IL, MERIDPLA42IN, MERIDPLA42IL Owner’s Manual  •  2519-981 Rev. E  •  1/19

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.  If you do 

experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a problem and 

the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.  Contact 

your dealer to arrange a service call by a qualified service technician.

C.  Troubleshooting

IntelliFire™ Touch

ECM LED Error 

Codes

Description

3 Red: 1 Green

IFT-RC400 error message:  ‘Appliance Safely Disabled’, pilot sparks for 60 sec, no flame 

rectification.

2 Red: 1 Green

IFT-RC400 display:  ‘Error Pilot Flame’, pilot valve solenoid not detected.

2 Red: 2 Green

Sparking feedback signal error, spark coil failure.

5 Red: 1 Green

IFT-RC400 display:  ‘Error Power Vent’ (if installed).

Error Codes:

Troubleshooting:

See Troubleshooting matrix for more detail on Lock-out Error Codes, Possible Causes and Corrective Actions.

Symptom

Possible Cause

Corrective Action

Pilot won’t light, module clicks but 

no spark 60 sec, 3 Red/1 Green 

Lock out.

Incorrect wiring.

Verify ‘S’ (White) sense wire and ‘I’ (orange) ignitor wire are 
connected to correct terminals on 

IFT-

ECM.

Loose connections or electrical 
shorts in wiring.

Verify no loose connections or electrical shorts in wiring from 
module to pilot assembly.  Verify wire insulation is not dam-
aged.  Verify wires are not grounding out to chassis, pilot burn-
er, or any other metal object.  Replace any damaged wires. 

Ignitor gap is too large.

Verify spark gap is approximately 0.095” (2.41 mm) to 0.135” 

(3.43 mm). 

Pilot won’t light, there is no noise 

or spark.

No AC power, AC/DC adaptor 

faulty, backup batteries (if 

being used) depleted, 

IFT-

ECM slider switch in OFF 
position.

Verify 

IFT-

ECM slider switch is in ON or 

IFT-

REM  position.  

Verify AC power available to junction box.  Verify AC/DC adap-
tor is plugged into junction box and ECM.  Verify AC/DC adaptor 

output voltage is between 5.7-6.3 Vdc.  If battery pack is used, 

check battery pack voltage is >4.2 V (if not, replace batteries). 

Shorted or loose connection 
in system wiring or wiring 
harness.

Verify system wiring configuration.  Remove and reinstall wir

-

ing  harness that plugs into module. Check continuity of wires 

in valve wiring harness.  Replace any damaged components. 

Poor or no system ground.

Verify black ground wire in valve harness is connected to metal 

chassis of fireplace. 

Pilot won’t light, there is no noise 

or spark, 2 Red/1 Green Lockout.

Pilot solenoid not detected.

Check if valve harness orange wire is connected to pilot so

-

lenoid  valve.    Check  pilot  solenoid  resistance,  nominal  is  40 

ohms.  If open or shorted, replace valve.  Check valve harness 

wire continuity, if open replace 6-pin harness.

Pilot won’t light, there is no noise 

or spark, 2 Red/2 Green Lockout.

Spark coil failure.

Replace ECM.

Summary of Contents for MERIDIAN PLATINUM Series

Page 1: ...ppliance installation manual for additional Commonwealth of Massachusetts requirements DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at risk individuals DO NOT store or use g...

Page 2: ...________________________________________________________ Gas and Electric Information Serial Number Type of Gas Model Number Not Not for use use with with solid solid fuel fuel Ne Ne doit doit pas entre entre utilise utilise avec avec un un combustible combustible solide solide This This appliance appliance must must be be installed installed in in accordance accordance with with local local codes...

Page 3: ...fications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Faith Wall Surface TV Guidelines 8 E Before Lighting Appliance 10 F Lighting Instructions IPI 11 G Appliance Break In 12 H Heat Management 12 I Operation During A Power Outage IntelliFire Touch 13 J Detailed Component Operating Instructions IntelliFire Touch 14 4...

Page 4: ...overage begins on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty shall commence no later than 24 months following the date of product shipment from HHT regardless of the inst...

Page 5: ... EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints accidents misuse scratches melted items or other external sources and re...

Page 6: ...and applicable sections of Gas Burn ing Heating Appliances for Manufactured Homes and Recreational Vehicles and Gas Fired Appliances for Use at High Altitudes Installation and service of this appliance should be performed by qualified personnel Hearth HomeTechnologiesrecommends NFI certified professionals MODELS MERIDPLA36IN MERIDPLA36IL MERIDPLA42IN MERIDPLA42IL LABORATORY Underwriters Laboratori...

Page 7: ...ren to NEVER touch the fireplace Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heater Glass Fronts Safety To prevent unintended operation when not using your fire place for an extended period of time summer months vacations trips etc Remove batteries from remote controls Turn off wall contr...

Page 8: ... 4 B FIXED GLASS ASSEMBLY NOT SHOWN SECTION 4 B MANTEL HEARTH not required FAN KIT SECTION 3 J CLEAR SPACE SECTION 3 A GRATE Figure 3 3 Good Faith Wall Surface Temperatures Above Appliance D Good Faith Wall Surface TV Guidelines MEASUREMENTS FROM TOP EDGE OF THE OPENING 6 in 18 in 24 in 30 in TO CEILING 12 in 127 F 123 F 132 F 135 F 147 F APPLIANCE FRONT FIREPLACE OPENING NOTICE Temperatures liste...

Page 9: ...anufacturer and from model to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable opera ng temperatures iden ed in the TV s technical speci ca ons Contact the TV s manufacturer directly if you cannot locate this informa on or have ques ons regarding the informa...

Page 10: ... materials have been removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that there are no gas leaks Ensure that the glass is sealed and in the proper position and that the integral barrier is in place WARNING Risk of Fire or Asphyxiation DO NOT op erate fireplace...

Page 11: ...low the gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand DO NOT D DO NOT use this appliance if any part has been under water Immediately call the control system and any gas control which has been under water For use with natural gas and propane A conversion kit as supplied by the manufac turer sha...

Page 12: ...t the fan speed or to turn the fan OFF The fan speed dynamic icon is used to change the setting G Appliance Break In Follow the initial break in procedure below to cure the materials used to manufacture the fireplace and the finishing materials around it The fireplace should be run three to four hours continuously on high Turn the fireplace off and allow it to cool completely Remove fixed glass as...

Page 13: ...wiring diagram is included in the Electrical section of the appliance Installation Manual 3 Turn the appliance on according to the instructions below for the appropriate type of control Standard Wall Switch or Factory Installed ON OFF Switch Toggle the switch as you would under normal circumstances Wireless Remote Remote receiver is integrated into the ignition module Use the remote to turn the ap...

Page 14: ...error When switched to the OFF position while the appliance is operating the system will shut down ON Position The appliance will ignite and run continuously at the HI flame setting No adjustment in flame height is possible Remote Position The remote position allows operation of the appliance from a wired wall switch IFT RC400 or IFT RC150 remote controls The IFT ECM switch must be in this positio...

Page 15: ... in the battery pack while using the transformer Remove batteries before using the transformer and unplug the transformer before installing the batteries Battery polarity must be correct or module damage will occur Optional Heat Zone Gas Kit The Heat Zone Gas heat management option is avail able for use with the MERIDPLA36I and MERIDPLA42I appliances The Heat Zone Gas Kit draws heat from your fire...

Page 16: ...move freely and no obstructions are present Reinstall decorative front B Maintenance Tasks Homeowner The following tasks may be performed annually by the homeowner If you are uncomfortable performing any of the listed tasks please call your dealer for a service ap pointment More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that contro...

Page 17: ...must be performed by a qualified ser vice technician Gasket Seal and Glass Assembly Inspection Frequency Annually By Qualified Service Technician Tools needed Protective gloves drop cloth and a stable work surface Inspect gasket seal and its condition Inspect fixed glass assembly for scratches and nicks that can lead to breakage when exposed to heat Confirm there is no damage to glass or glass fra...

Page 18: ...Glowing embers with new dime size pieces DO NOT block ports or obstruct lighting paths Refer to installation manual for proper ember placement Verify batteries have been removed from battery back up IPI systems to prevent premature battery failure or leaking Check for smooth lighting and ignition carryover to all ports Verify that there is no ignition delay Inspect and ensure the lighting of the m...

Page 19: ...d glass assembly with care Glass is breakable Avoid striking scratching or slamming glass Avoid abrasive cleaners DO NOT clean glass while it is hot Remove decorative front from fireplace and set aside on work surface Pull the four glass assembly latches out of the groove on the glass frame Remove glass assembly from the appliance See Figure 4 1 Note It may be necessary to remove logs in order to ...

Page 20: ... noise Noise is caused by metal expanding and contracting as it heats up and cools down similar to the sound produced by a furnace or heating duct This noise does not affect the operation or longevity of the fireplace Is it normal to see the pilot flame burn continually In an intermittent pilot ignition system IPI the pilot flame should turn off when appliance is turned off Some optional control s...

Page 21: ...laced in the path of an air draft or vent Move the remote away from the direct path of air flow The remote acts as the thermostat Flame Modulation The control system is designed to automatically adjust the flame intensity based on the difference between the desired room temperature and actual temperature In thermostat mode the hearth appliance will start in HI flame but as the actual temperature a...

Page 22: ...y no loose connections or electrical shorts in wiring from module to pilot assembly Verify wire insulation is not dam aged Verify wires are not grounding out to chassis pilot burn er or any other metal object Replace any damaged wires Ignitor gap is too large Verify spark gap is approximately 0 095 2 41 mm to 0 135 3 43 mm Pilot won t light there is no noise or spark No AC power AC DC adaptor faul...

Page 23: ...cted to green main valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5 Red 1 Green Lockout Power Vent PV Failure Power Vent blower defective check wiring to IFT ACM check if blower is working Check if PV pressure switch is connected to brown and black ...

Page 24: ...led to operate your fireplace For safety Install a switch lock or a wall remote control with child protection lockout feature Keep remote controls out of reach of children See your dealer if you have questions Install approved accessories per instructions included with accessories Contact your dealer for a list of ap proved accessories WARNING Risk of Fire and Electric Shock Use ONLY Hearth Home T...

Page 25: ...TS PART NUMBER Log Assembly LOGSDBDV36PLAT Y 1 Log A SRV2454 701 2 Log B SRV2454 702 3 Log C SRV2397 705 4 Log E SRV2454 705 5 Log D SRV2454 704 6 Log F SRV2454 706 7 Log G SRV2454 707 8 Log H SRV2397 706 9 Insulation Board 2166 136 10 Exhaust Baf e 2506 109 11 Grate Assembly 2397 015 12 Burner Assembly 2454 007 Y 13 Burner Skirt SRV2208 102 BK 14 Base Pan Assembly 2454 024 15 Valve Assembly Refer...

Page 26: ...Log Assembly LOGSDBDV42PLAT Y 1 Log A SRV2454 701 2 Log B SRV2454 702 3 Log C Qty 2 req SRV2454 707 4 Log D SRV2397 702 5 Log E Qty 2 req SRV2454 704 6 Log F SRV2454 705 7 Log G SRV2454 706 8 Log H SRV2397 706 9 Insulation Board 2170 136 10 Exhaust Baf e 2507 110 11 Grate Assembly 2398 015 12 Burner Assembly NG 2455 007 Y Burner Assembly Propane 2455 008 Y 13 Burner Skirt SRV2208 102 BK 14 Base Pa...

Page 27: ...6 15 4 Valve Bracket 2118 104 15 5 Battery Pack SRV2326 134 Y 15 6 Power Supply SRV2326 131 Y 15 7 Flex Ball Valve Assembly SRV302 320 Y 15 8 Valve NG 2166 302 Y Valve Propane 2166 303 Y 15 9 Male Connector Pkg of 5 303 315 5 Y 15 10 Bulkhead W Flex SRV7000 156 Y 15 11 Shutter Bracket Assembly 2118 121 Y 15 12 Harness IFT 6 Pin Wiring SRV2326 132 Y 15 13 Module IFT Control 2326 130 Y Ori ce 33C NG...

Page 28: ...045 Y Jumper Wire SRV2187 198 Y Lava Rock 4021 297 Mineral Wool SRV14333 Refractory Set Tavern Brown MERIDPLA36IN IL BRICK36MERTB MERIDPLA42IN IL BRICK42MERTB Refractory Set Cottage Red MERIDPLA36IN IL BRICK36MERCR MERIDPLA42IN IL BRICK42MERCR Refractory Set Herringbone MERIDPLA36IN IL BRICK36MERTBH MERIDPLA42IN IL BRICK42MERTBH Surround Assembly MERIDPLA36IN IL 2166 019 MERIDPLA42IN IL 2170 019 T...

Page 29: ..._____________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ Printed in U S A Copyright 2019 DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party responsible for use and operatio...

Reviews: