Service Parts

MERC32

Beginning Manufacturing Date: June 2016 

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. 

Hearth and 

Home Technologies does not sell directly to consumers

. Provide model number and serial number when 

requesting service parts from your dealer or distributor.

Stocked 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

15.1

Pilot Assembly NG 

2106-169

Y

Pilot Assembly LP

2107-070

Y

Pilot Tube

SRV485-301

Y

15.2

3-Hole Grommet

2118-420

15.3

Valve Bracket 

2118-104

15.4

Flexible Gas Connector  

302-320A

Y

15.5

Valve NG 

750-500

Y

Valve LP

750-501

Y

15.6

Thermostat Wire

2118-170

Y

15.7

Module

593-592

Y

15.8

Wire Assembly 

593-590A

Y

15.9

Flex Tube Assembly

7000-156

Y

15.10

3 Volt Transformer  

593-593A

Y

15.11

Battery Pack 

593-594A

Y

15.12

Ori

¿

 ce NG (#45C)

582-845

Y

Ori

¿

 ce LP (#55C)

582-855

Y

15.13

Male Connector

Pkg of 5

303-315/5

Conversion Kit  NG

NGK-3732

Y

Conversion Kit  LP 

LPK-3732

Y

Regulator NG

NGK-DXV

Y

Regulator LP

LPK-DXV

Y

Pilot Ori

¿

 ce NG

593-528

Y

Pilot Ori

¿

 ce LP

593-527

Y

#15 IPI Valve Assembly

15.1

14.13

15.2

15.3

15.4

15.5

15.6

15.7

15.8

15.9

15.10

15.11

15.12

Summary of Contents for MERCURY MERC32VN

Page 1: ...a licensed plumber or gas fitter SeeTable of Contents for location of additional Commonwealth of Massachusetts requirements Models MERC32IN MERC32IL MERC32VN MERC32VL DANGER HOT GLASS WILL CAUSE BURN...

Page 2: ...az Gaz N NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved Approv...

Page 3: ...ions Tempered 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Faith Wall Surface TV Guidelines 8 E...

Page 4: ...begins on the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an i...

Page 5: ...VE WARRANTY EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface fi...

Page 6: ...This product is listed to ANSI standards for Vented Gas Fireplace Heaters and applicable sections of Gas Burn ing Heating Appliances for Manufactured Homes and Recreational Vehicles and Gas Fired Appl...

Page 7: ...ing the pilot light on fireplaces with a standing pilot remove the fixed glass assembly so you can de tect presence of residual gas build up See Standing Pilot Lighting instructions and Maintenance Ta...

Page 8: ...er natural gas or propane Make sure the appliance is compatible with gas type selected for installation site Conversions must be made by a qualified service technician using Hearth Home Technologies s...

Page 9: ...ual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable opera ng temperatu...

Page 10: ...air shutter adjustment Ensure that there are no gas leaks Ensure that the glass is sealed and in the proper position and that the integral barrier is in place WARNING Risk of Fire or Asphyxiation DO N...

Page 11: ...liquids having flammable vapors away DO NOT operate the appliance with fixed glass assembly removed cracked or broken Replacement of the fixed glass assembly should be done by a licensed or qualified...

Page 12: ...AC OR 220 240 VAC TO THE CON TROL VALVE Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with thi...

Page 13: ...propriate type of control Standard Wall Switch or Factory Installed ON OFF Switch Toggle the switch as you would under normal circumstances Multifunctional Wired Wall Switch Control System Locate the...

Page 14: ...nt is used because the pilot burner flame is only present when the main burner is operating When the main burner is off the pilot is also off NOTICE Batteries should not be placed in the battery pack...

Page 15: ...in place on fireplace Hold glass in place with one hand and secure glass latches with the other hand Reinstall decorative front B Maintenance Tasks Homeowner The following tasks may be performed annua...

Page 16: ...or sheds Inspect for corrosion or separation Verify weather stripping sealing and flashing remains intact Inspect draft shield to verify it is not damaged or missing C Maintenance Tasks Qualified Ser...

Page 17: ...or proper ember placement Verify batteries have been removed from battery back up IPI systems to prevent premature battery failure or leaking Check for smooth lighting and ignition carryover to all po...

Page 18: ...n 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing process A non abrasive cleaner such as gas fireplace glass cleaner may be necessary See your dealer Metallic no...

Page 19: ...e Inspect pilot assembly for shorted sparker wire or cracked insulator around electrode Replace pilot if necessary 2 Pilot won t light there is no noise or spark A No power or transformer installed in...

Page 20: ...orifice is installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod C Module is...

Page 21: ...ure that the thermocouple connection at the gas valve is fully in serted and tight hand tighten plus 1 4 turn Verify proper voltage output from the thermocouple to the valve Place one millivolt meter...

Page 22: ...nk Refill the fuel tank B Improper gas inlet pressure Natural gas should be 5 10 in w c LP should be 11 13 in w c Verify pressure with manometer C Inner vent pipe leaking exhaust gases back into the s...

Page 23: ...you have questions Install approved accessories per instructions included with accessories Contact your dealer for a list of ap proved accessories WARNING Risk of Fire and Electric Shock Use ONLY Hear...

Page 24: ...Log 3 SRV2401 703 4 Log 4 SRV2218 706 5 Log 5 SRV2397 705 6 Log 6 SRV2397 705 7 Burner Assembly 2355 007 Y 8 Base Pan 2355 110 9 Glass Door Assembly GLA 550TR Y 10 Fire Screen Front SRV2401 021 Y 11...

Page 25: ...Pilot Assembly LP 2107 070 Y Pilot Tube SRV485 301 Y 15 2 3 Hole Grommet 2118 420 15 3 Valve Bracket 2118 104 15 4 Flexible Gas Connector 302 320A Y 15 5 Valve NG 750 500 Y Valve LP 750 501 Y 15 6 Th...

Page 26: ...DESCRIPTION COMMENTS PART NUMBER 16 1 Pilot Assembly NG 2103 010 Y Pilot Assembly LP 2103 011 Y Pilot Tube SRV485 301 Y 16 2 3 Hole Grommet 2118 420 16 3 Valve Bracket 2118 104 16 4 Flexible Gas Conn...

Page 27: ..._________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party responsible for use an...

Reviews: