Majestic • MARQ42STIN Owner Manual • 2272-981 Rev. J • 7/18
18
C. Maintenance Tasks - Qualified Service
Technician
The
following tasks must be performed by a qualified ser
-
vice technician.
Glass Cleaning
(Exterior and Interior of Installed Glass)
Frequency:
Seasonally
By:
Qualified Service Technician
Tools Needed
: Protective gloves, glass cleaner, drop
cloth and a stable work surface.
WARNING!
Risk of Injury!
Glass installation and re-
moval should be performed only by a qualified service
technician.
CAUTION!
Handle fixed glass assembly with care.
Glass is breakable.
• Avoid striking, scratching or slamming glass
• Avoid abrasive cleaners
• DO NOT
clean glass while it is hot
•
Prepare a work area large enough to accommodate fixed
glass assembly and door frame by placing a drop cloth
on a flat, stable surface.
Note
: Fixed glass assembly and gasketing may have res
-
idue that can stain carpeting or floor surfaces.
•
Remove decorative front from fireplace and set aside
on work surface.
• See Section 11.A in the installation manual for instructions
to remove fixed glass assembly.
• Clean glass with a non-abrasive commercially available
cleaner.
- Light deposits: Use a soft cloth with soap and water
- Heavy deposits: Use commercial fireplace glass
cleaner (consult with your dealer)
• Carefully set fixed glass assembly in place on fireplace.
Hold glass in place with one hand and secure glass
latches with the other hand.
• Inspect and operate all glass latches to ensure they move
freely and no obstructions are present.
• Reinstall decorative front.
Gasket Seal and Glass Assembly Inspection
Frequency:
Annually
By:
Qualified Service Technician
Tools needed:
Protective gloves, drop cloth and a stable
work surface.
• Inspect gasket seal and its condition.
• Inspect fixed glass assembly for scratches and nicks that
can lead to breakage when exposed to heat.
• Confirm there is no damage to glass or glass frame.
Replace as necessary.
• Verify that fixed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
Logs
Frequency:
Annually
By:
Qualified Service Technician
Tools needed:
Protective gloves.
• Inspect for damaged or missing logs. Replace as neces-
sary. Refer to Installation manual for log placement instruc-
tions.
• Verify correct log placement and no flame impingement
causing sooting. Correct as necessary.