background image

1

Majestic  • Owner’s Manual MARQ36IN, MARQ42IN  •  2270-981 Rev. i  •  8/17

Owner’s Manual

Care and Operation

NOTICE: DO NOT discard this manual!

This appliance may be installed as an OEM 

installation in manufactured home (USA 

only) or mobile home and must be installed 

in accordance with the manufacturer’s 

instructions and the 

Manufactured Home 

Construction and Safety Standard,

 

Title 24 

CFR, Part 3280 

in the United States

or the 

Standard for Installation in Mobile Homes, 

CAN/CSA Z240 MH Series,

 in Canada.

This appliance is only for use with the type(s) 

of gas indicated on the rating plate. This 

appliance is not convertible for use with other 

gases, unless a certified kit is used.

In the Commonwealth of Massachusetts installation must be 

performed by a licensed plumber or gas fitter.

See appliance installation manual for additional 

Commonwealth of Massachusetts requirements.

INSTALLER:  Leave this manual with party responsible for use and operation.

OWNER:  Retain this manual for future reference.

                 Contact your dealer with questions regarding installation, operation or service.

DANGER

HOT GLASS 

WILL 

CAUSE BURNS.

DO NOT TOUCH 

GLASS 

UNTIL COOLED.

NEVER 

ALLOW CHILDREN

 TO TOUCH GLASS.

A  barrier  designed  to  reduce  the  risk  of 

burns from the hot viewing glass is provided 

with this appliance and shall be installed for 

the  protection  of  children  and  other  at-risk 

individuals.

• 

DO NOT

 store or use gasoline or other flam

-

mable vapors and liquids in the vicinity of this 

or any other appliance.

•  What to do if you smell gas   

DO NOT

 try to light any appliance.

DO NOT

 touch any electrical switch. 

DO 

NOT

 use any phone in your building.

-  Leave the building immediately.
-  Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas sup-

plier’s instructions.

-  If you cannot reach your gas supplier, call 

the fire department.

•  Installation and service must be performed 

by a qualified installer, service agency, or the 

gas supplier.

WARNING: 

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly 

could result in serious injury, death, or 

property damage. 

Models: 

MARQ36IN, MARQ42IN

MARQUIS

SERIES

Pour demander un exemplaire en français de ce Manuel 

du propriétaire, visitez www.majesticproducts.com/trans-

lations.

Summary of Contents for MARQ36IN

Page 1: ...dealer with questions regarding installation operation or service DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce th...

Page 2: ...NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved Approved Minimu...

Page 3: ...BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Faith Wall Surface TV Guidelines 9 E Before Lighting...

Page 4: ...the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent...

Page 5: ...Y EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may...

Page 6: ...he National Fuel Gas Code ANSI Z223 1 latest edition in the U S A and the CAN CGA B149 Installation Codes in Canada 2 Product Specific Information B Glass Specifications This appliance is equipped wit...

Page 7: ...front of the fireplace or block louvers High temperatures may start a fire See Figure 3 1 Avoid placing candles and other heat sensitive objects on mantel or hearth Heat may damage these objects Figur...

Page 8: ...ecified and approved parts FIXED GLASS ASSEMBLY NOT SHOWN SECTION 4 B 4 C LED REPLACEMENT SECTION 4 C MANTEL CLEAR SPACE SECTION 3 A RATING PLATE GLASS CLIP TOOL LOCATION SECTION 3 B OPERATION DURING...

Page 9: ...WARNING Risk of Fire or Asphyxiation DO NOT op erate fireplace with fixed glass assembly removed MEASUREMENTS FROM TOP EDGE OF THE OPENING 22 IN 34 IN 40 IN 46 IN 52 IN MIN CEILING 28 IN APPLIANCE FRO...

Page 10: ...rom model to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowa...

Page 11: ...nce Hot while in operation DO NOT touch Keep children clothing furniture gasoline and other liquids having ammable vapors away DO NOT operate the appliance with xed glass assembly removed cracked or b...

Page 12: ...ction 4 B Clean fixed glass assembly See Section 4 Replace the fixed glass assembly and run continuously on high an additional 12 hours This cures the materials used to manufacture the fire place NOTI...

Page 13: ...Locate the battery tray and insert four AA cell batteries Battery polarity must be correct or module damage will occur See Figure 3 5 A complete wiring diagram is included in the Electrical section o...

Page 14: ...omatically shut down the fireplace after 9 hours of continuous operation without receiving a command from the IFT RC400 or IFT RC150 2 If multiple control options are installed the IFT ECM will respon...

Page 15: ...and during cool down Use care and wear gloves when opening the front and accessing compo nents inside the appliance Be aware the appliance may be HOT use care in accessing the IFT ECM Set the IFT ECM...

Page 16: ...sess condition of screen and replace as necessary Inspect for scratches dents or other damage and repair as necessary Check that louvers are not blocked Vacuum and dust surfaces Remote Control Frequen...

Page 17: ...th care Glass is breakable Avoid striking scratching or slamming glass Avoid abrasive cleaners DO NOT clean glass while it is hot NOTICE Use only glass cleaner compatible with ce ramic glass Other typ...

Page 18: ...emove the ember glass assembly The LED box can be lifted out of the fireplace at this point See replacement parts list for LED part numbers Burner Ignition and Operation Frequency Annually By Qualifie...

Page 19: ...and adhesives used around the fireplace Film on the glass This is a normal result of the curing process of the paint and logs Glass should be cleaned within 3 to 4 hours of initial burning to remove...

Page 20: ...ront of it The remote acts as the thermostat Remote is placed in the path of an air draft or vent Move the remote away from the direct path of air flow The remote acts as the thermostat Flame Modulati...

Page 21: ...witch is in ON or IFT REM position Verify AC power available to junction box Verify AC DC adap tor is plugged into junction box and ECM Verify AC DC adaptor output voltage is between 5 7 6 3 Vdc If ba...

Page 22: ...valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5...

Page 23: ...ls out of reach of children See your dealer if you have questions Optional Heat Zone Gas Kit An optional Heat Zone Kit is available for your appli ance It must be installed by a qualified service tech...

Page 24: ...SRV2270 702 3 Log 3 SRV2270 703 4 Log 4 SRV2270 704 5 Log 5 SRV2270 706 6 Log 6 SRV2271 705 7 Log 7 SRV2271 707 8 Heat Shield Header Qty 2 req 2280 105 9 Heat Shield Valve 2281 153 10 Junction box 40...

Page 25: ...2 Log 2 SRV2271 702 3 Log 3 SRV2271 703 4 Log 4 SRV2271 704 5 Log 5 SRV2271 705 6 Log 6 SRV2271 706 7 Log 7 SRV2271 707 8 Heat Shield Header Qty 2 req 2281 105 9 Heat Shield Valve 2281 153 10 Junctio...

Page 26: ...03 315 5 Y 13 5 Valve NG 2166 302 Y Valve LP 2166 303 Y 13 6 Flex Ball Valve Assembly 12 302 320A Y 13 7 Rocker Switch 2206 299 Y 13 8 Grommet 2118 420 13 9 Wire Battery jumps 10 in 2281 196 Y 13 10 B...

Page 27: ...714 21 8 Refractory Back SRV2270 715 Refractory Herringbone BRICKMQ36HB 22 1 Refractory Top SRV2270 726 22 2 Refractory Left SRV2270 723 22 3 Refractory Left Base SRV2270 728 22 4 Refractory Left Base...

Page 28: ...SRV2271 714 21 8 Refractory Back SRV2271 715 Refractory Herringbone BRICKMQ42HB 22 1 Refractory Top SRV2271 726 22 2 Refractory Left SRV2271 723 22 3 Refractory Left Base SRV2271 728 22 4 Refractory...

Page 29: ...2 req 2146 413 Y Glass Latch Assembly MARQ36 Qty 3 req 2155 045 Y MARQ42 Qty 4 req Kapton Lens Light Orange Qty 2 req 2166 171 Y Lava Rock 4021 296 Mineral Wool 050 721 Nut 1 4 20 Hex Insert 7000 236...

Page 30: ...eat from the appliance adjacent windows and doors HVAC vents and direct sunlight To use the thermostat function access the main menu screen on your remote and select thermostat Next simply select your...

Page 31: ...ble venting configurations A Power Vent is a standard accessory on some products and an option on others When a Power Vent is detected a pre purge of 120 seconds is automatically required During this...

Page 32: ...reminder If the remote 300 hour maintenance message does not clear on the first try repeat above steps INDICATORS Your appliance has been disabled Please contact your dealer and report this issue Call...

Page 33: ...______________________________________________ ________________________________________________________________________________ ________________________________________________________________________...