17
Majestic • ECHEL36IN-C, ECHEL36STIN-C, ECHEL48IN-C, ECHEL48STIN-C, ECHEL60IN-C, ECHEL72IN-C Owner’s Manual • 2608-981 Rev. B • 7/19
DANGER
DANGER
•
Wait five minutes to allow possible accumulated gas to
clear.
• Remove decorative barrier front from appliance.
• Remove bottom glass shield from appliance as shown
in Figure 3.11.
• Locate reset switch inside the appliance. See Figure
3.12. Hold reset switch down for one second and
release. A “beep” will signal module is reset.
Appliances with Wall Switch and Remote
•
Turn wall switch back to “ON” position. Go to
main menu on remote control and restart fireplace.
The fireplace will start as it would under normal
circumstances.
Appliances with Wall Switch Only:
•
Turn wall switch back to “ON” position. The fireplace
will ignite as it would under normal circumstances.
Appliances with Remote Only:
•
Turn fireplace back on using the main menu on the
remote control. The fireplace will ignite as it would
under normal circumstances.
• Reinstall bottom glass shield.
• Reinstall decorative barrier front on appliance.
• If the IFT-ECM re-enters the LOCK-OUT condition
after this procedure, contact your dealer for service.
CONTROL MODULE (IFT-ECM)
CONTROL CAVITY
(SHOWN IN GRAY)
RESET SWITCH
3.12 IFT-ECM and Reset Switch Location - Top View
Figure 3.11 Bottom Panel Location
BOTTOM PANEL SCREW LOCATIONS
BOTT
OM P
ANEL
BOTT
OM GLASS SHIELD
Appliance ON/OFF:
A wall control, thermostat or remote control may be used
to control the ON/OFF function of the appliance. Follow
instructions included with the installed control.
LED’s
• This appliance is shipped standard with LED lights.
• The LED’s must be used in conjunction with the IFT-
RC400 remote control. The intensity of the these lights
is controlled through the RC400 remote control.